NEC Code Questions Practice Test-9
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-9 — Question List

Question 1: what size of conductor must be used to protect against over current for a continuous load of 22 amperes at 75<sup>0</sup>C?

  • 10 THWN
  • 12 THWN
  • 16 THWN
  • 8 THWN

NEC Reference: NEC 27.5

Question 2: What size of feeder conductors are required for a dwelling unit which has a calculated load of 240 A. The service disconnect is rated for 250 A and feeder conductors carry entire load of the dwelling unit?

  • 1/0 AWG
  • 2/0 AWG
  • 3/0 AWG
  • 4/0 AWG

NEC Reference: NEC 207.5

Question 3: What size branch circuit conductor is required for a 4000 W, 240 electric water heater?

  • 12 AWG
  • 14 AWG
  • 8 AWG
  • 10 AWG

NEC Reference: NEC 422.10(A)

Question 4: How many number of 500 kcmil THWN conductors that can be installed in a 4 in. * 4 in. wireway?

  • 4 conductors
  • 5 conductors
  • 6 conductors
  • 7 conductors

NEC Reference: NEC 376.22(A)

Question 5: If a service is fed by three parallel sets of 400 kcmil conductors, what is the required conductor size for GEC?

  • 3/0 AWG
  • 2/0 AWG
  • 2 AWG
  • 4 AWG

NEC Reference: NEC 250.166

Question 6: Which of the following is the size of single supply-side bonding jumper is required for three metal raceways, each containing 300 kcmil service conductors?

  • 2 AWG
  • 3 AWG
  • 1/0 AWG
  • 1 AWG

NEC Reference: NEC 250.102(C)(1)

Question 7: If the length doesn’t exceed ………. Feet the cord and plug connections are allowed for swimming pool pump motors?

  • 3 feet
  • 5 feet
  • 10 feet
  • 8 feet

Question 8: After the demand factor is applied , what is the general lighting load of a hospital which is having 80,000 sq ft area?

  • 42,000 VA
  • 1,60,000 VA
  • 58,000 VA
  • 82, 000 VA

NEC Reference: NEC 220.12

Question 9: A 115/230 delta configured three phase transformer is rated at 45 KVA. What is its high-leg voltage of the transformer secondary?

  • 230 volts
  • 399 volts
  • 199 volts
  • 208 volts

Question 10: What is the maximum size over current device is required for a 4200 W, 240 V electric water heater connected in a building.

  • 25 A
  • 30 A
  • 35 A
  • 40 A

NEC Reference: NEC 26.25