NEC_PRACTICE NEC 2023

NEC 2023 Code Questions Practice Test 19

Free NEC 2023 practice test with 30 mixed-review questions covering transformers, motors, industrial control, and general code knowledge. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 19 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 19
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 19 — Question List

Question 1: For a transformer 1000 volts or less with primary protection only, the overcurrent device is generally sized at not more than what percent of primary current?

  • 125 %
  • 25 %
  • 500 %
  • No protection is needed

NEC Reference: NEC Table 450.3(B)

Question 2: Transformer secondary conductors are often sized under special "tap" rules found in:

  • NEC 240.21(C)
  • NEC 90.1
  • NEC 110.3
  • No such rule exists

NEC Reference: NEC 240.21(C)

Question 3: Dry-type transformers rated over a certain kVA installed indoors generally require a fire-resistant:

  • Transformer room
  • Nothing at all
  • Wooden shed
  • Cardboard enclosure

NEC Reference: NEC 450.21

Question 4: A continuous-duty motor rated more than 1 horsepower generally needs overload protection sized at what percent of full-load current for a service factor of 1.15 or more?

  • 125 %
  • 25 %
  • 500 %
  • 0 %

NEC Reference: NEC 430.32(A)(1)

Question 5: When a motor disconnect is opened, the motor control circuit should generally also be:

  • Disconnected from its source
  • Left fully energized
  • Turned up to full speed
  • Ignored completely

NEC Reference: NEC 430.74

Question 6: A motor controller must have a horsepower rating that is:

  • Not lower than the motor rating
  • Always lower than the motor
  • Random, it does not matter
  • Zero

NEC Reference: NEC 430.83

Question 7: An individual disconnecting means must generally be provided for each motor and located:

  • Within sight of the motor
  • On a different property
  • Nowhere, none is required ever
  • Only in a locked vault far away

NEC Reference: NEC 430.102(A)

Question 8: An industrial control panel must be marked with the manufacturer's name and:

  • Voltage, current, and short-circuit rating
  • Nothing else at all
  • The installer's birthday
  • A random logo only

NEC Reference: NEC 409.110

Question 9: A capacitor must be provided with a means to drain the stored charge, reducing residual voltage within:

  • A specified short time period
  • Never, charge stays forever
  • 10 years
  • It is not addressed by the NEC

NEC Reference: NEC 460.6

Question 10: An overcurrent device is generally required for a capacitor to protect against:

  • Short circuits and overcurrent
  • Nothing, none is ever needed
  • Rain only
  • Sunlight only

NEC Reference: NEC 460.8(B)

Question 11: A vehicle-mounted generator frame may serve as the grounding electrode when the generator supplies:

  • Equipment mounted on or bonded to the vehicle
  • An entire apartment building
  • A different city
  • Nothing at all

NEC Reference: NEC 250.34(A)

Question 12: A "qualified person" under the NEC is one who has the skills and knowledge related to:

  • The equipment and its hazards
  • Cooking recipes
  • Nothing in particular
  • Painting techniques

NEC Reference: NEC Article 100

Question 13: "Identified (as applied to equipment)" means recognized as suitable for:

  • The specific purpose
  • Any random purpose
  • No purpose at all
  • Decoration only

NEC Reference: NEC Article 100

Question 14: The "authority having jurisdiction" (AHJ) is the organization responsible for:

  • Enforcing the Code
  • Selling equipment
  • Nothing at all
  • Cooking inspections only

NEC Reference: NEC Article 100

Question 15: Equipment that is "listed" appears in a list published by an organization that evaluates:

  • Products or materials for safety
  • Restaurant menus
  • Nothing relevant
  • Paint colors

NEC Reference: NEC Article 100

Question 16: For reasonable efficiency, combined voltage drop on a feeder and branch circuit is generally recommended not to exceed:

  • 5 %
  • 50 %
  • 0.5 %
  • 100 %

NEC Reference: NEC 210.19(A) Informational Note

Question 17: The ampacity of a conductor is generally found using ampacity tables together with:

  • Adjustment and correction factors
  • The installer's guess
  • Nothing else
  • The color of insulation only

NEC Reference: NEC 310.14

Question 18: The ampacity of a conductor connected to a terminal must not exceed the terminal's:

  • Temperature rating
  • Color
  • Weight
  • Brand name

NEC Reference: NEC 110.14(C)

Question 19: Terminals for aluminum conductors must be marked and used according to manufacturer instructions to avoid:

  • Corrosion or connection failure
  • Extra shine
  • Nothing at all
  • A pleasant smell

NEC Reference: NEC 110.14(B)

Question 20: When conductors are run in parallel to share current, the minimum conductor size permitted is generally:

  • 1/0 AWG
  • 14 AWG
  • 18 AWG
  • There is no minimum

NEC Reference: NEC 310.10(G)

Question 21: Paralleled conductors in each phase must be the same length and:

  • Same material, size, and insulation
  • Different sizes always
  • Different materials always
  • It does not matter at all

NEC Reference: NEC 310.10(G)(1)

Question 22: The feeder or service neutral load is generally calculated as the maximum unbalance of the:

  • Load between neutral and ungrounded conductor
  • The color of the wire
  • The homeowner's preference
  • Nothing at all

NEC Reference: NEC 220.61

Question 23: General lighting load for dwelling units is calculated at a set amount of volt-amperes per:

  • Square foot of floor area
  • Household pet
  • Window count only
  • Nothing, it is a fixed number always

NEC Reference: NEC 220.42

Question 24: A demand factor is applied to certain dwelling loads because not all loads are likely to operate:

  • At the same time
  • Ever, under any condition
  • On weekends only
  • Never, they are always all off

NEC Reference: NEC Table 220.42

Question 25: NEC 220.82 provides an optional method for calculating the feeder or service load of a:

  • Dwelling unit
  • Gas station canopy
  • Swimming pool only
  • Nothing at all

NEC Reference: NEC 220.82

Question 26: A 20-ampere branch circuit with multiple receptacle outlets generally has a maximum cord-and-plug load per receptacle of:

  • 16 amperes
  • 5 amperes
  • 50 amperes
  • 100 amperes

NEC Reference: NEC Table 210.21(B)(2)

Question 27: A single receptacle installed on an individual branch circuit must have an ampere rating not less than:

  • The branch-circuit rating
  • Half the branch-circuit rating
  • Zero
  • Any random rating

NEC Reference: NEC 210.21(B)(1)

Question 28: A separately derived system, such as one from a transformer secondary, generally needs its own:

  • System bonding jumper and grounding connection
  • No grounding at all
  • A different building entirely
  • Nothing extra

NEC Reference: NEC 250.30(A)

Question 29: A separately derived system is a premises wiring system whose power is derived from a source with no direct connection to:

  • Conductors of another supply system
  • The building foundation
  • The roof
  • Nothing relevant

NEC Reference: NEC Article 100

Question 30: Electrical equipment must be installed in a neat and workmanlike manner, which is a requirement found in:

  • NEC 110.12
  • NEC 90.9
  • NEC 250.1
  • There is no such requirement

NEC Reference: NEC 110.12