NEC 2023 Code Questions Practice Test 13

Free NEC 2023 practice test with 30 questions on wiring methods, conduit, cable types, and appliances. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 13 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 13
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 13 — Question List

Question 1: Liquidtight flexible metal conduit is often used to connect:

  • Motors and vibrating equipment
  • Overhead service drops only
  • Nothing, it has no use
  • Underground burial with no conduit

NEC Reference: NEC 350.10

Question 2: Type UF cable is designed for:

  • Direct burial underground
  • Indoor use only
  • It has no permitted use
  • Telephone wiring only

NEC Reference: NEC 340.10

Question 3: Type AC cable is generally permitted for:

  • Dry, indoor locations
  • Wet locations with no protection
  • Underground burial
  • It has no permitted use

NEC Reference: NEC 320.10

Question 4: Compared to Type AC cable, Type MC cable is permitted for direct burial when:

  • Listed for that use
  • It has no listed uses
  • Never, under any condition
  • Only in dry attics

NEC Reference: NEC 330.10

Question 5: A long PVC conduit run needs an expansion fitting when the expected length change is more than:

  • 1/4 inch
  • 2 inches
  • 6 inches
  • 1 foot

NEC Reference: NEC 352.44

Question 6: Rigid metal conduit is generally supported at intervals not more than:

  • 5 feet
  • 10 feet
  • 15 feet
  • 20 feet

NEC Reference: NEC 344.30

Question 7: The largest EMT trade size permitted by the NEC is:

  • 2 inches
  • 4 inches
  • 6 inches
  • There is no limit

NEC Reference: NEC 358.20

Question 8: Conductors in a wireway must not fill more than what percent of the wireway area?

  • 20 %
  • 40 %
  • 53 %
  • 75 %

NEC Reference: NEC 376.22(A)

Question 9: An auxiliary gutter must not extend more than what distance beyond the equipment it supplements?

  • 10 feet
  • 30 feet
  • 100 feet
  • There is no limit

NEC Reference: NEC 366.12

Question 10: Where flexibility is needed after installation, FMC can be left unsupported for up to:

  • 3 feet
  • 6 feet
  • 10 feet
  • 12 feet

NEC Reference: NEC 348.30(A)

Question 11: A storage-type water heater's overcurrent protection should not exceed what percent of the branch-circuit rating?

  • 100 %
  • 125 %
  • 150 %
  • 200 %

NEC Reference: NEC 422.11(E)

Question 12: A storage water heater of 120 gallons or less is treated, for circuit sizing, as a:

  • Continuous load
  • Momentary load
  • It is exempt from sizing rules
  • A non-continuous load, always

NEC Reference: NEC 422.13

Question 13: Every fixed appliance needs a way to disconnect it, which can be provided by:

  • A breaker, switch, or attachment plug
  • The nameplate alone
  • Nothing is ever required
  • A fused disconnect only

NEC Reference: NEC 422.30

Question 14: A built-in dishwasher may be cord-and-plug connected if the cord length is:

  • 3 to 4 feet
  • 6 to 8 inches
  • 10 to 15 feet
  • Any length

NEC Reference: NEC 422.16(B)(1)

Question 15: A wall-mounted range hood may be cord-and-plug connected if the cord length is:

  • 6 to 12 inches
  • 18 to 36 inches
  • 48 to 60 inches
  • Any length

NEC Reference: NEC 422.16(B)(4)

Question 16: Fixed electric heating equipment needs a disconnect that is within sight, or if not, is:

  • Lockable in the open position
  • Never required
  • Hidden inside the heater
  • In another building

NEC Reference: NEC 424.19

Question 17: A receptacle should not be mounted above a baseboard heater if the maker's instructions:

  • Prohibit that location
  • Are always ignored
  • Do not matter
  • Only cover paint color

NEC Reference: NEC 424.9

Question 18: A single electric range rated 12 kW or less generally has a demand load of:

  • 6 kW
  • 8 kW
  • 10 kW
  • 12 kW

NEC Reference: NEC Table 220.55

Question 19: Along a kitchen countertop, receptacles must be placed so no point is more than how far from an outlet?

  • 12 inches
  • 24 inches
  • 48 inches
  • 6 feet

NEC Reference: NEC 210.52(C)(1)

Question 20: Small appliance circuits must only supply kitchen and dining area receptacles, not:

  • Lighting outlets in another room
  • More kitchen receptacles
  • The refrigerator
  • The dining room table area

NEC Reference: NEC 210.52(B)(1)

Question 21: Central heating equipment must generally be supplied by:

  • An individual branch circuit
  • The kitchen circuit
  • Any lighting circuit
  • A shared water heater circuit

NEC Reference: NEC 210.11(C)(4)

Question 22: A multiwire branch circuit feeding devices on the same yoke needs a way to:

  • Disconnect all ungrounded conductors together
  • Disconnect only the neutral
  • Nothing extra is needed
  • Disconnect one wire at a time

NEC Reference: NEC 210.4(B)

Question 23: A continuous load is one where the maximum current continues for at least:

  • 1 hour
  • 3 hours
  • 30 minutes
  • 24 hours

NEC Reference: NEC Article 100

Question 24: "Readily accessible" means capable of being reached quickly, without:

  • Climbing over things or using a ladder
  • Asking for a key
  • Turning on a light
  • Opening a door

NEC Reference: NEC Article 100

Question 25: A feeder is the circuit conductors between the service equipment and:

  • The final branch-circuit overcurrent device
  • The street
  • A neighbor's house
  • Nothing

NEC Reference: NEC Article 100

Question 26: Dry-type transformer vent openings must not be blocked by:

  • Walls or other obstructions
  • Nothing, blocking is fine
  • Paint only
  • It does not matter

NEC Reference: NEC 450.9

Question 27: An autotransformer supplying a branch circuit needs overcurrent protection set at not more than what percent of rated input current?

  • 125 %
  • 250 %
  • 400 %
  • No protection is needed

NEC Reference: NEC 450.4

Question 28: For sizing motor conductors, the full-load current should come from:

  • The NEC full-load current tables
  • The nameplate current, always
  • A guess
  • The panel rating

NEC Reference: NEC 430.6(A)(1)

Question 29: A motor has a full-load current of 16 amperes. What is the minimum branch-circuit conductor ampacity?

  • 16 amperes
  • 20 amperes
  • 24 amperes
  • 32 amperes

NEC Reference: NEC 430.22(A)

Question 30: A motor must be placed where it gets enough air flow and where maintenance can be:

  • Easily done
  • Never performed
  • Done only by the factory
  • Not a factor at all

NEC Reference: NEC 430.14(A)

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)