NEC_PRACTICE NEC 2023

NEC 2023 Code Questions Practice Test 10

Free NEC 2023 practice test with 30 questions on surge protection, expanded GFCI rules, emergency disconnects, and grounding. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 10 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 10
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 10 — Question List

Question 1: A surge-protective device (SPD) is required at the service equipment for:

  • Dwelling unit services
  • Nothing, SPDs are never required
  • Only outdoor sheds
  • Only detached garages

NEC Reference: NEC 230.67

Question 2: Besides dwelling units, the SPD requirement in NEC 230.67 was expanded to also cover:

  • Hotel and motel guest rooms
  • Nothing was added
  • Only industrial warehouses
  • Only parking garages

NEC Reference: NEC 230.67

Question 3: In a dwelling kitchen, GFCI protection is required for all 125 through 250 volt receptacles, including those serving:

  • Refrigerators and disposals
  • Only the countertop
  • Nothing besides the counter
  • None of the kitchen

NEC Reference: NEC 210.8(A)(6)

Question 4: A receptacle within 6 feet of a wet bar sink in a dwelling requires:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A dedicated circuit only

NEC Reference: NEC 210.8(A)(9)

Question 5: One- and two-family dwellings need an emergency disconnect that is:

  • Outdoors and readily accessible
  • Hidden inside a locked closet
  • Not required at all
  • Located only in the attic

NEC Reference: NEC 230.85

Question 6: An emergency disconnect for a dwelling must be marked as:

  • "Emergency Disconnect"
  • No marking at all
  • Only a house number
  • The installer's name only

NEC Reference: NEC 230.85

Question 7: Under Condition 1, for equipment rated 0-150 volts to ground, the minimum working space depth is:

  • 2 feet
  • 3 feet
  • 4 feet
  • 6 feet

NEC Reference: NEC 110.26(A)(1)

Question 8: A service has 3/0 AWG copper conductors. What is the minimum copper grounding electrode conductor size?

  • 8 AWG
  • 6 AWG
  • 4 AWG
  • 2 AWG

NEC Reference: NEC 250.66

Question 9: A rod electrode must be at least:

  • 4 feet
  • 8 feet
  • 12 feet
  • 16 feet

NEC Reference: NEC 250.52(A)(5)

Question 10: Each 14 AWG conductor in a box fill calculation needs a volume allowance of:

  • 1.5 in3
  • 2.0 in3
  • 2.25 in3
  • 2.5 in3

NEC Reference: NEC Table 314.16(B)

Question 11: In a dwelling living room, no point along the wall should be more than how far from a receptacle?

  • 4 feet
  • 6 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 210.52(A)(1)

Question 12: What is the maximum standard overcurrent device rating for 14 AWG copper wire?

  • 15 amperes
  • 20 amperes
  • 25 amperes
  • 30 amperes

NEC Reference: NEC 240.4(D)(3)

Question 13: A motor has a full-load current of 24 amperes. What is the minimum branch-circuit conductor ampacity?

  • 24 amperes
  • 30 amperes
  • 36 amperes
  • 48 amperes

NEC Reference: NEC 430.22(A)

Question 14: What is the minimum service disconnect rating for a single-family dwelling?

  • 60 amperes
  • 100 amperes
  • 150 amperes
  • 200 amperes

NEC Reference: NEC 230.79(C)

Question 15: A panelboard is generally protected by an overcurrent device rated no higher than the panel, except when the panel is rated:

  • 400 amperes or more
  • 100 amperes or more
  • 50 amperes or more
  • There is no exception

NEC Reference: NEC 408.36

Question 16: A circuit is protected by a 40 ampere breaker. What is the minimum copper equipment grounding conductor size?

  • 14 AWG
  • 12 AWG
  • 10 AWG
  • 8 AWG

NEC Reference: NEC 250.122

Question 17: Tamper-resistant receptacles are required for almost all:

  • Dwelling unit receptacles
  • Only outdoor receptacles
  • Only garage receptacles
  • None are required

NEC Reference: NEC 406.12

Question 18: A box in a wet location must be listed for the purpose and:

  • Prevent moisture buildup
  • Be left open
  • Be made of wood
  • It does not matter

NEC Reference: NEC 314.15

Question 19: A grounded conductor 6 AWG or smaller must be identified by:

  • White or gray
  • Black
  • Red
  • Blue

NEC Reference: NEC 200.6(A)

Question 20: All grounding electrodes present at a building must be:

  • Bonded together
  • Kept fully separate
  • Reduced to just one, and the rest removed
  • Ignored

NEC Reference: NEC 250.50

Question 21: AFCI protection is required for 120 volt, 15 and 20 ampere circuits in nearly all areas of:

  • A dwelling unit
  • Only garages
  • Only outdoors
  • AFCI is never required

NEC Reference: NEC 210.12(A)

Question 22: When more than 3 current-carrying conductors share a raceway, the ampacity must be:

  • Adjusted downward
  • Left unchanged
  • Increased
  • Doubled

NEC Reference: NEC Table 310.15(C)(1)

Question 23: The standard ampacity tables are based on an ambient temperature of:

  • 0 C
  • 30 C
  • 60 C
  • 90 C

NEC Reference: NEC 310.14

Question 24: A dwelling bathroom needs at least one 20 ampere circuit supplying only:

  • Bathroom receptacle outlets
  • The whole house
  • The garage
  • The kitchen

NEC Reference: NEC 210.11(C)(3)

Question 25: A motor has a normal (under 1.15) service factor. What is the maximum overload setting, as a percent of full-load current?

  • 100 %
  • 115 %
  • 125 %
  • 150 %

NEC Reference: NEC 430.32(A)(1)

Question 26: Every circuit at a panelboard must be identified on:

  • A circuit directory
  • Nothing, it is optional
  • The electric bill
  • A note to the buyer

NEC Reference: NEC 408.4(A)

Question 27: The minimum width of working space in front of equipment is:

  • 24 inches
  • 30 inches
  • 36 inches
  • 48 inches

NEC Reference: NEC 110.26(A)(2)

Question 28: NM cable must be supported at intervals not more than:

  • 2 feet
  • 4 1/2 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 334.30

Question 29: The disconnect for air-conditioning equipment must be located:

  • Within sight of the equipment
  • Hidden inside the unit
  • At the main panel only
  • Anywhere on the property

NEC Reference: NEC 440.14

Question 30: The equipotential bonding grid around a pool is used to reduce:

  • Voltage differences and shock risk
  • Water usage
  • Pool deck cracking
  • It has no safety purpose

NEC Reference: NEC 680.26(B)

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)