NEC 2023 Code Questions Practice Test 2

Free NEC 2023 practice test with 30 questions covering GFCI protection near sinks, outside feeder disconnect ratings, service drop clearances over residential property, the 25-ohm supplemental ground rod rule, and bonding of gas piping. Every answer includes an NEC 2023 reference.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 2 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 2
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 2 — Question List

Question 1: Which of the following following locations , easily ignitable fibers / flyings are stored?

  • Class I Division I
  • Class III Division I
  • Class III Division 2
  • Class I Division 2

NEC Reference: NEC 500.5(D)(2)

Question 2: What is the minimum size electrical service is required for a single family dwelling unit?

  • 100 amperes
  • 50 amperes
  • 150 amperes
  • 175 amperes

NEC Reference: NEC 230.79(C)

Question 3: What must be the electrical fuse rating to protect 12 AWG Branch conductor?

  • 20 amperes
  • 35 amperes
  • 25 amperes
  • 40 amperes

NEC Reference: NEC 240.4(D)

Question 4: A sign outlet of an commercial occupancy accessible to pedestrians is a .......................... load

  • continuous
  • non continuous

Question 5: What is the minimum feeder/service conductor calculated load for an electrical sign?

  • 15000 VA
  • 12000 VA
  • 18000 VA
  • 10000 VA

NEC Reference: NEC 220.14(F)

Question 6: What is the minimum ampere rating of short circuit ground fault protective device that can be used for individual motor-compressor?

  • 12 amperes
  • 15 amperes
  • 20 amperes
  • 18 amperes

NEC Reference: NEC 440.22(A)

Question 7: An industrial heating appliances rated at 40 A is supplied by a tap conductor. what should be the minimum tap conductor ampacity?

  • 20 amperes
  • 10 amperes
  • 30 amperes
  • 25 amperes

NEC Reference: NEC 210.19(A)(4)

Question 8: If a single dwelling family unit consists of one air conditioning unit rated at 4 KW and fixed heating equipment rated at 3 KW. What is the total dwelling unit calculated load?

  • 4 KW
  • 7 KW
  • 3.5 KW
  • 3 KW

NEC Reference: NEC 220.60

Question 9: A 4000 watts electric oven is connected to 480 volts electric circuit. what is the resistance of heating element?

  • 57.6 ohms
  • 8.33 ohms
  • 0.12 ohms
  • 38.4 ohms

Question 10: What is the maximum rating of panel boards containing 30 ampere or less snap switches?

  • 30 amperes
  • 120 amperes
  • 45 amperes
  • 200 amperes

NEC Reference: NEC 408.36(A)

Question 11: Receptacles located within 6 feet of the outside edge of a sink other than a kitchen sink, such as a wet bar sink, require:

  • GFCI protection
  • No protection
  • AFCI protection only
  • A dedicated circuit only, no GFCI

NEC Reference: NEC 210.8(A)(9)

Question 12: For a single-branch circuit installation (not more than two 2-wire branch circuits), the outside feeder/branch-circuit disconnecting means must have a rating of not less than:

  • 30 amperes
  • 10 amperes
  • 100 amperes always
  • There is no minimum

NEC Reference: NEC 225.39

Question 13: Per NEC Table 230.24(B), overhead service conductors of 0-750 volts over residential property and driveways generally require a minimum vertical clearance of:

  • 8 feet
  • 12 feet
  • 18 feet
  • 22 feet

NEC Reference: NEC Table 230.24(B)

Question 14: The ampere rating of a circuit breaker must be:

  • Durably marked and visible after installation
  • Hidden inside the panel enclosure
  • Not required at all
  • Marked only on the inside of the breaker

NEC Reference: NEC 240.83(A)

Question 15: A single rod, pipe, or plate electrode with a resistance to earth of 25 ohms or less does not require a supplemental electrode. If the resistance exceeds 25 ohms, what must be done?

  • A supplemental electrode must be installed
  • Nothing further is required
  • The electrode must be removed entirely
  • The service must be de-energized permanently

NEC Reference: NEC 250.53(A)(2)

Question 16: Metal gas piping that may become energized must be bonded to which of the following?

  • The service equipment or grounding electrode system
  • It is never bonded
  • Only the gas meter, and nothing else
  • The telephone system only

NEC Reference: NEC 250.104(B)

Question 17: A box or conduit body must be installed at each conductor splice point, outlet, switch point, junction point, or pull point, except for which of the following?

  • Listed fittings identified for the purpose
  • Splices are never allowed anywhere
  • A box is always required with no exceptions
  • Tape wrapped in the wall cavity, unenclosed

NEC Reference: NEC 300.15

Question 18: When conductors are installed in an ambient temperature different from that used to develop the ampacity tables, the conductor ampacity must be:

  • Corrected using the applicable temperature correction factor
  • Left unchanged regardless of ambient temperature
  • Always doubled
  • Ambient temperature is never a factor

NEC Reference: NEC 310.15(B)

Question 19: The sizing rules of NEC 314.28(A) for straight and angle pulls in pull boxes apply specifically to raceways containing conductors of what minimum size?

  • 4 AWG and larger
  • 14 AWG and smaller only
  • It applies to all sizes equally
  • Only 18 AWG fixture wire

NEC Reference: NEC 314.28(A)

Question 20: The maximum trade size of electrical metallic tubing (EMT) permitted by the NEC is:

  • 2 inches
  • 4 inches
  • 6 inches
  • There is no maximum

NEC Reference: NEC 358.20

Question 21: A dimmer switch used to control general lighting must be:

  • Listed for the specific type of load controlled
  • Used to control motor loads without restriction
  • It does not matter what load type is connected
  • Rated for double the connected load, with no listing needed

NEC Reference: NEC 404.14(E)

Question 22: A receptacle being replaced in a location where AFCI protection is currently required by 210.12 must be replaced with:

  • An AFCI-protected receptacle (or equivalent protection at the panel)
  • A standard non-AFCI receptacle
  • AFCI protection is never required on replacement
  • A GFCI receptacle only, ignoring AFCI

NEC Reference: NEC 406.4(D)(4)

Question 23: A permanently connected motor-operated appliance rated over 1/8 horsepower, that is not readily accessible, must be provided with a disconnecting means that is:

  • Capable of being locked in the open position
  • Not required at all
  • Always within sight, with no exceptions
  • Only a cord-and-plug is acceptable

NEC Reference: NEC 422.31(C)

Question 24: Duct heaters must be interlocked with the associated air-moving equipment so that the heater:

  • Cannot energize unless the fan is operating
  • Runs independently of the fan at all times
  • Has no relationship to the fan
  • Runs only when the fan is off

NEC Reference: NEC 424.65

Question 25: Per NEC Table 430.52, for a general polyphase motor, the maximum standard rating of a dual-element (time-delay) fuse is what percentage of motor full-load current?

  • 150 %
  • 175 %
  • 250 %
  • 300 %

NEC Reference: NEC Table 430.52

Question 26: Overload protection for a hermetic refrigerant motor-compressor may be provided by which of the following methods?

  • A separate overload relay or integral thermal protector
  • No overload protection is ever required
  • A padlock on the disconnect only
  • Painting the compressor a warning color

NEC Reference: NEC 440.52

Question 27: Generators must be installed in a location that provides:

  • Adequate ventilation and protection for the environment
  • No particular consideration is required
  • Direct connection to gas piping only
  • Placement indoors only, never outdoors

NEC Reference: NEC 445.4

Question 28: A disconnecting means must be provided to disconnect each transformer from all ungrounded conductors. This disconnect must be located:

  • Within sight, or lockable in the open position
  • Never required for transformers
  • Only at the main service equipment
  • Inside the transformer enclosure, hidden

NEC Reference: NEC 450.14

Question 29: In a Class I, Division 1 hazardous location, the primary wiring method permitted is:

  • Threaded rigid metal conduit or threaded steel IMC
  • Open knob-and-tube wiring
  • Standard NM cable
  • Bare conductors run in free air

NEC Reference: NEC 501.10(A)

Question 30: Compared to Division 1, a Class I, Division 2 location permits a broader range of wiring methods, including:

  • EMT and listed MC cable, under specific conditions
  • No additional wiring methods are ever permitted
  • Open bare conductors only
  • Standard NM cable with no restrictions

NEC Reference: NEC 501.10(B)