NEC 2020 Code Questions Practice Test 17

Free NEC 2020 practice test with 30 questions on hazardous locations, pools, signs, heating equipment, and key NEC definitions. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2020 Code Questions Practice Test 17 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2020
NEC 2020 Code Questions Practice Test 17
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2020 Code Questions Practice Test 17 — Question List

Question 1: The main wiring method for a Class I, Division 1 hazardous location is:

  • Threaded rigid metal conduit
  • Open knob-and-tube wiring
  • Standard NM cable
  • Bare wire in open air

NEC Reference: NEC 501.10(A)

Question 2: A conduit run from a Class I, Division 2 space into an unclassified space needs a seal within what distance of the boundary?

  • 5 feet
  • 10 feet
  • 20 feet
  • 50 feet

NEC Reference: NEC 501.15

Question 3: Equipment used in a hazardous location must be approved for the specific class and:

  • Group and properties of the hazard
  • Color of the building
  • Nothing else
  • The installer's preference

NEC Reference: NEC 500.8(A)

Question 4: Intrinsically safe conductors are identified by the color:

  • Blue
  • Red
  • Black
  • Brown

NEC Reference: NEC 504.80(C)

Question 5: An electric sign needs a disconnect that is within sight of the sign, or if not, it must be:

  • Lockable in the open position
  • Left unlocked always
  • Removed entirely
  • Not required at all

NEC Reference: NEC 600.6

Question 6: Electric signs and outline lighting must generally be:

  • Listed
  • Homemade
  • Exempt from all rules
  • Approved by the owner only

NEC Reference: NEC 600.3

Question 7: A portable sign in a dry location is supplied by a cord no longer than:

  • 8 feet
  • 12 feet
  • 16 feet
  • 20 feet

NEC Reference: NEC 600.10(D)(2)

Question 8: The smallest conductor permitted for pool bonding is generally:

  • 12 AWG
  • 10 AWG
  • 8 AWG
  • 6 AWG

NEC Reference: NEC 680.26

Question 9: An outlet supplying a pool pump motor, whether by cord or direct connection, must be provided with:

  • GFCI protection
  • AFCI protection only
  • No protection
  • Overvoltage protection only

NEC Reference: NEC 680.21(C)

Question 10: Wiring methods at a marina must resist the wet, salty environment, and generally include:

  • Rigid metal conduit or PVC
  • Standard indoor NM cable
  • Bare wire in open air
  • No wiring method restrictions apply

NEC Reference: NEC 555.15

Question 11: The overall length of a mobile home power supply cord must not be more than:

  • 20 feet
  • 36 1/2 feet
  • 50 feet
  • There is no limit

NEC Reference: NEC 550.10(J)

Question 12: Which of the following is an accepted power source for a legally required standby system?

  • A generator set
  • A garden hose
  • A telephone line
  • No source is ever acceptable

NEC Reference: NEC 701.12

Question 13: Fixed electric heating equipment needs a disconnect that is within sight, or if not, is:

  • Lockable in the open position
  • Never required
  • Hidden inside the heater
  • Located in another building

NEC Reference: NEC 424.19

Question 14: Embedded floor heating cable should not be installed under permanently fixed cabinets because:

  • Heat loss is blocked, risking overheating
  • It looks bad
  • It costs more money
  • There is no reason

NEC Reference: NEC 424.44(E)

Question 15: Receptacle outlets should not be mounted above an electric baseboard heater if the maker's instructions:

  • Prohibit that location
  • Are always ignored
  • Do not matter
  • Only cover paint color

NEC Reference: NEC 424.9

Question 16: A storage-type water heater's overcurrent protection should not go over what percent of the branch-circuit rating?

  • 100 %
  • 125 %
  • 150 %
  • 200 %

NEC Reference: NEC 422.11(E)

Question 17: A single electric range rated 12 kW or less generally has a branch-circuit demand load of:

  • 6 kW
  • 8 kW
  • 10 kW
  • 12 kW

NEC Reference: NEC Table 220.55

Question 18: Along a kitchen countertop, receptacles must be placed so no point is more than how far from an outlet?

  • 12 inches
  • 24 inches
  • 48 inches
  • 6 feet

NEC Reference: NEC 210.52(C)(1)

Question 19: The small appliance circuits must only supply receptacles in the kitchen and dining areas, not:

  • Lighting outlets in another room
  • More kitchen receptacles
  • The refrigerator
  • The dining room table area

NEC Reference: NEC 210.52(B)(1)

Question 20: Central heating equipment (other than fixed electric heat) must be supplied by:

  • An individual branch circuit
  • The kitchen circuit
  • Any lighting circuit
  • A shared water heater circuit

NEC Reference: NEC 210.11(C)(4)

Question 21: A multiwire branch circuit feeding more than one device on the same yoke needs a way to:

  • Disconnect all ungrounded conductors together
  • Disconnect only the neutral
  • Nothing extra is needed
  • Disconnect one wire at a time only

NEC Reference: NEC 210.4(B)

Question 22: A load where the maximum current is expected to continue for how long is called a continuous load?

  • 1 hour or more
  • 3 hours or more
  • 30 minutes or more
  • 24 hours or more

NEC Reference: NEC Article 100

Question 23: A branch circuit is the wiring between the final overcurrent device and:

  • The outlet(s)
  • The utility pole
  • Another overcurrent device only
  • The grounding rod

NEC Reference: NEC Article 100

Question 24: A feeder is defined as all circuit conductors between the service equipment and:

  • The final branch-circuit overcurrent device
  • The street
  • A neighbor's house
  • Nothing, feeders end at the pole

NEC Reference: NEC Article 100

Question 25: A "qualified person" has skills and knowledge about the equipment, plus:

  • Safety training on the hazards
  • A college degree only
  • No training of any kind
  • A driver's license

NEC Reference: NEC Article 100

Question 26: "Readily accessible" means capable of being reached quickly, without needing to:

  • Climb over things or use a ladder
  • Ask for a key
  • Turn on a light
  • Open a door

NEC Reference: NEC Article 100

Question 27: "Identified," as used in the NEC, means suitable for the specific:

  • Purpose or application
  • Color scheme
  • Price range
  • Brand name only

NEC Reference: NEC Article 100

Question 28: The "grounded conductor" is the conductor that is:

  • Intentionally grounded
  • Never grounded
  • Always the hot wire
  • Made of aluminum only

NEC Reference: NEC Article 100

Question 29: The equipment grounding conductor connects non-current-carrying metal parts to the:

  • Grounded conductor or grounding electrode conductor
  • Nearest tree
  • Phone line
  • Nothing at all

NEC Reference: NEC Article 100

Question 30: A "dwelling unit" is defined as one or more rooms for independent living with facilities for:

  • Sleeping, cooking, and sanitation
  • Parking only
  • Storage only
  • Nothing specific

NEC Reference: NEC Article 100