NEC_PRACTICE NEC 2023

NEC 2023 Code Questions Practice Test 7

Free NEC 2023 practice test with 30 questions covering equipment grounding conductor extension via GFCI, festoon lighting conductor sizing, rain-tight service raceways, fixture wire overcurrent protection, and intersystem bonding termination. Every answer includes an NEC 2023 reference.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 7 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 7
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 7 — Question List

Question 1: An enclosed channel which holds wires,cables or bus-bars is called as:

  • raceway
  • panel board
  • switch board
  • receptacle

Question 2: An ohmmeter connected across 240 electric heater shows the reading of 20 ohms. What is the current flow in the electric heater?

  • 12 amperes
  • 0.083 ohms
  • 0.5 ohms
  • 8 amperes

Question 3: A residence has an area of 60 feet by 30 feet. Which of the following is the minimum allowable 120 volts , 20 amperes branch circuits required for general lightening?

  • 3
  • 2
  • 4
  • 1

Question 4: A 4 AWG THHN conductor is used to connect a 480 Volts, 3 phase 35 KVA transformer to panel board. what is the maximum length of conductor that can be used in which the voltage drop does not cross 3%?  

  • 320 feet
  • 640 feet
  • 720 feet
  • 540 feet

NEC Reference: NEC Chapter 9, Table 8

Question 5: The over load protection must be provided for the motor if it is rated more than ............... Hp.

  • 1/8 Hp
  • 1/4 Hp
  • 1/2 Hp
  • 1 Hp

NEC Reference: NEC 430.32(A)

Question 6: What is the maximum continuous load that can be connected to 240 volts 30 amperes branch circuit?

  • 24 amperes
  • 30 amperes
  • 20 amperes
  • 26 amperes

NEC Reference: NEC 210.20

Question 7: A incandescent-lamp must not be equipped with medium base if rated more than ............... watts.

  • 150 watts
  • 200 watts
  • 300 watts
  • 400 watts

NEC Reference: NEC 410.103

Question 8: In a 14 feet residential hallway, how many minimum number of receptacles are required?

  • 2
  • 1
  • 3
  • 4

NEC Reference: NEC 210.52

Question 9: For an electric motor rated not more than ............... horsepower, the branch circuit can server as disconnecting means.

  • 1/2 horsepower
  • 3/4 horsepower
  • 1 horsepower
  • 1/8 horsepower

NEC Reference: NEC 422.31(A)

Question 10: What is the minimum volt ampere rating of a 180,000 square foot school?

  • 540 KVA
  • 320 KVA
  • 720 KVA
  • 480 KVA

NEC Reference: NEC 220.12

Question 11: For an existing branch circuit without an equipment grounding conductor, a nonlocking-type 15 or 20 ampere receptacle is permitted to be grounded via connection to which of the following, per 250.130(C)?

  • The grounding electrode system, or a GFCI without a new EGC
  • A garden hose
  • It can never be grounded on an existing circuit
  • A telephone line

NEC Reference: NEC 250.130(C)

Question 12: For overhead festoon lighting, conductors must be no smaller than what size, unless supported by messenger wire?

  • 12 AWG
  • 2 AWG
  • 18 AWG
  • 6 AWG

NEC Reference: NEC 225.6(B)

Question 13: Where a service raceway is exposed to the weather, it must be:

  • Rain-tight and suitably drained
  • Left open on top for ventilation
  • Made of untreated wood
  • It does not matter

NEC Reference: NEC 230.53

Question 14: Fixture wires are protected against overcurrent according to their own ampacity table rather than the general conductor OCPD rule of 240.4, per:

  • NEC Table 402.5
  • NEC Table 310.16
  • No table applies to fixture wire
  • NEC Table 220.12

NEC Reference: NEC 240.5

Question 15: The grounded conductor connection to the grounding electrode system at a service must be made:

  • Accessible
  • Always encased in concrete
  • Painted shut
  • It does not matter

NEC Reference: NEC 250.24(A)(1)

Question 16: An intersystem bonding termination must be provided at the service equipment, or at the disconnecting means for a separate building/structure, for the purpose of connecting:

  • Communications system grounding/bonding conductors
  • The gas meter only
  • Nothing, it has no purpose
  • A lightning rod system exclusively

NEC Reference: NEC 250.94

Question 17: Raceways and cables above a suspended ceiling must be independently supported, and must NOT be supported by:

  • The ceiling support wires or grid, unless listed for it
  • This is always permitted, with no restriction
  • Nothing may ever support a raceway
  • Only drywall screws directly

NEC Reference: NEC 300.11(A)

Question 18: The allowable ampacities shown in the standard NEC ampacity tables are based on no more than three current-carrying conductors in a raceway or cable, at an ambient temperature of:

  • 30 C (86 F)
  • 0 C (32 F)
  • 100 C (212 F)
  • There is no reference temperature

NEC Reference: NEC 310.14

Question 19: Where one or more equipment grounding conductors enter a box, they are counted in the box fill calculation as:

  • One single conductor, sized from the largest EGC present
  • Each EGC counted separately, no matter how many
  • They are never counted at all
  • Counted as two conductors, always

NEC Reference: NEC 314.16(B)(2)

Question 20: A run of EMT must not contain more than the equivalent of how many quarter bends (360 degrees total) between pull points, such as boxes or conduit bodies?

  • Four quarter bends (360 degrees)
  • One quarter bend (90 degrees)
  • Ten quarter bends (900 degrees)
  • There is no limit

NEC Reference: NEC 358.26

Question 21: A receptacle installed in the floor of a dwelling unit must be:

  • Listed for installation in the floor
  • Any standard wall receptacle works fine
  • Floor receptacles are prohibited entirely
  • It does not matter what type is used

NEC Reference: NEC 406.10

Question 22: A cord-and-plug-connected portable immersion heater used to heat liquids in a container must be provided with:

  • GFCI protection
  • No protection at all
  • AFCI protection only
  • A dedicated 50 ampere circuit only

NEC Reference: NEC 422.41

Question 23: Heating cables installed within a concrete or poured masonry floor must be identified as suitable for that use, since:

  • Embedded use imposes different thermal/mechanical stresses
  • Any heating cable works in any application
  • It has no bearing on the cable choice
  • Concrete floors never use heating cable

NEC Reference: NEC 424.44(B)

Question 24: A feeder tap conductor supplying a motor load must have overcurrent protection consistent with:

  • Part IV of Article 430 (branch-circuit protection rules)
  • No protection is ever required for motor taps
  • Article 250 only
  • It has no relationship to Article 430

NEC Reference: NEC 430.28

Question 25: Per NEC Article 100, the "branch-circuit selection current" is the value provided by a manufacturer to be used instead of rated-load current when it is:

  • Greater than the rated-load current
  • Always less than the rated-load current
  • Equal to the voltage rating
  • Never used in sizing calculations

NEC Reference: NEC Article 100

Question 26: A secondary tie is a circuit that connects two power sources, such as two transformer secondaries, together at a point other than:

  • Their common coupling point
  • The generator only
  • It has no defined meaning
  • The service disconnect only

NEC Reference: NEC 450.6

Question 27: In a Class I hazardous location, open (uninsulated) energized parts such as buses, contacts, or terminals are:

  • Not permitted
  • Always required to be exposed for cooling
  • Permitted with no restriction
  • Only permitted at night

NEC Reference: NEC 501.25

Question 28: The overall length of a mobile home power-supply cord, measured from the face of the attachment plug to the point the cord enters the mobile home, must not exceed:

  • 36 1/2 feet
  • 10 feet
  • 100 feet
  • There is no maximum

NEC Reference: NEC 550.10(J)

Question 29: Wiring methods installed at a marina or boatyard must be suitable for the wet, corrosive environment, generally including:

  • Rigid metal conduit, IMC, PVC, or listed corrosion-resistant MC cable
  • Standard indoor NM cable
  • Open bare conductors
  • No wiring method restrictions apply at marinas

NEC Reference: NEC 555.15

Question 30: A portable generator must be installed and used in accordance with the manufacturer's instructions, considering ventilation and fuel-related fire and carbon monoxide hazards. This general installation guidance is found in:

  • NEC 445.4, together with the manufacturer's instructions
  • Nowhere, this is not addressed anywhere
  • Only the local pizza restaurant's policy
  • The vehicle registration office

NEC Reference: NEC 445.4

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)