NEC 2023 Code Questions Practice Test 5

Free NEC 2023 practice test with 30 questions covering dwelling and non-dwelling GFCI protection, outdoor lighting circuit disconnects, minimum service disconnect ratings, separately derived system bonding, and cable clearance under metal roof decking. NEC 2023 references included.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 5 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 5
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 5 — Question List

Question 1: What is the maximum voltage drop in branch conductor recommended by NEC ?

  • 2 %
  • 3 %
  • 5 %
  • 6 %

NEC Reference: NEC 210.19(A) Informational Note No. 4

Question 2: what is the minimum general lightening load required for 3500 square foot ware house as permitted by NEC ?

  • 700 VA
  • 3500 VA
  • 7000 VA
  • 4500 VA

NEC Reference: NEC 220.12

Question 3: If a 20 ampere AC snap switch is used to disconnect a 1.5 HP motor what must be the maximum full load current of a motor?

  • 16 amperes
  • 20 amperes
  • 15 amperes
  • 17 amperes

NEC Reference: NEC 430.109(C)(2)

Question 4: What is the maximum continuous load that can be connected to 240 volts 20 ampere branch circuit?

  • 16 amperes
  • 20 amperes
  • 14 amperes
  • 10 amperes

NEC Reference: NEC 210.20

Question 5: In a single family dwelling unit when four or more appliances are fastened in a place and connected to the same feeder then ....... percent demand factor can be applied in calculating total demand load.

  • 75
  • 85
  • 83
  • 90

NEC Reference: NEC 220.53

Question 6: What is the the minimum size copper wire that can be used for outside overhead wiring, if the wire carries more than 600 volts?

  • No. 6 AWG
  • No. 8 AWG
  • No. 10 AWG
  • No. 12 AWG

NEC Reference: NEC 225.6(A)(2)

Question 7: What is the maximum allowable voltage between two adjacent snap switches are receptacles placed in a enclosure?

  • 300 volts
  • 240 volts
  • 480 volts
  • 120 volts

NEC Reference: NEC 404.8(B)

Question 8: Which of the following is the smallest size fixture wire allowed?

  • No . 18 AWG
  • No . 12 AWG
  • No . 14 AWG
  • No . 20 AWG

NEC Reference: NEC 410.54(B)

Question 9: NEC 210.8 is divided into subsections covering GFCI requirements for dwelling units and for other than dwelling units. This split exists because:

  • Dwelling and non-dwelling occupancies have different requirements
  • GFCI is only required in dwelling units
  • GFCI is only required in commercial buildings
  • There is no meaningful distinction

NEC Reference: NEC 210.8

Question 10: Outdoor lighting equipment supplied by 277 or 480 volt circuits must have branch circuits arranged so that:

  • All ungrounded conductors are disconnected simultaneously
  • No disconnecting means is ever required
  • The neutral alone may be disconnected separately with no restriction
  • It does not matter how the circuits are arranged

NEC Reference: NEC 225.7(B)

Question 11: For installations not covered by the single-circuit, two-circuit, or one-family-dwelling rules of 230.79, the minimum service disconnect rating is:

  • 60 amperes
  • 15 amperes
  • 30 amperes
  • 200 amperes

NEC Reference: NEC 230.79(D)

Question 12: Certain conductor applications, such as motor circuit conductors and fixture wires, have overcurrent protection requirements found in their own specific articles rather than the general ampacity-based rule of 240.4. This exception is found in:

  • NEC 240.4(G)
  • NEC 90.1
  • NEC 110.3
  • No such exception exists

NEC Reference: NEC 240.4(G)

Question 13: For a separately derived system, such as the secondary of a transformer, the system bonding jumper must be installed:

  • At the source, or the first disconnect, but not both
  • At every downstream panel
  • It is never required for separately derived systems
  • Only at the far end of the circuit

NEC Reference: NEC 250.30(A)

Question 14: Bonding is required, as necessary, to ensure electrical continuity and the capacity to safely conduct:

  • Any fault current likely to be imposed
  • Only normal operating current
  • Nothing — bonding has no functional purpose
  • Only lightning current

NEC Reference: NEC 250.90

Question 15: Cables and raceways installed above a corrugated sheet metal roof decking, without additional support, must maintain a minimum distance of:

  • 1 1/2 inches
  • 1/4 inch
  • 6 inches
  • No clearance is required

NEC Reference: NEC 300.4(E)

Question 16: When a pull box has more than one row of raceway entries, each row must be calculated:

  • Individually, using the largest raceway in that row
  • All rows are ignored except the first
  • Multiple rows are never permitted
  • Only the smallest raceway counts

NEC Reference: NEC 314.28(A)(3)

Question 17: Intermediate metal conduit (IMC) is prohibited from being used in which condition, unless supplementary corrosion protection is applied?

  • Severe corrosive influences
  • Any dry, indoor location
  • Standard residential closets
  • Above suspended ceilings

NEC Reference: NEC 342.14

Question 18: All cut ends of rigid metal conduit must be:

  • Reamed to remove rough edges
  • Left sharp for a tighter fitting connection
  • Never reamed, this is prohibited
  • Painted only, with no reaming

NEC Reference: NEC 344.28

Question 19: The NEC generally does not specify whether a receptacle must be installed with the grounding slot up or down, except where the receptacle or listing instructions require a specific orientation. What governs the correct orientation in that case?

  • The listing and manufacturer's installation instructions
  • There is never any requirement, ever
  • A coin flip
  • Local custom only, with no code basis

NEC Reference: NEC 406.5

Question 20: Panelboards must have circuits and circuit modifications arranged so as to avoid overloading of the:

  • Supply conductors or bus assembly
  • The building foundation
  • The homeowner's budget
  • Nothing, arrangement is irrelevant

NEC Reference: NEC 408.3(A)

Question 21: The fluorescent luminaire disconnecting means requirement of NEC 410.130(G) specifically applies to fixtures installed in:

  • Multiwire branch circuits with serviceable double-ended ballasts
  • Single-circuit installations only, with no exceptions
  • It applies to every luminaire regardless of type
  • It applies only to LED luminaires

NEC Reference: NEC 410.130(G)(1)

Question 22: A single branch-circuit breaker is permitted to serve as the disconnecting means for fixed electric space-heating equipment without an additional switch when:

  • It is within sight, or lockable in the open position
  • It is never permitted
  • It is located in a different building entirely
  • Any breaker anywhere in the building qualifies

NEC Reference: NEC 424.19(A)

Question 23: A time-delay fuse rated at not more than 125% of motor full-load current is permitted to be used for overload protection where the higher percentage overload relay setting from Table 430.32 is:

  • Not otherwise readily available or practical
  • Fuses are never permitted for motor overload
  • It has no bearing on the choice
  • Only for motors under 1/8 hp

NEC Reference: NEC 430.32(C)

Question 24: Air-conditioning or refrigerating equipment that uses a standard motor (not a hermetic motor-compressor) must be marked in accordance with:

  • Article 430
  • Article 500
  • Article 90
  • No marking requirement applies

NEC Reference: NEC 440.4(B)

Question 25: A two-wire, DC generator is permitted to have overcurrent protection provided in:

  • Only one conductor, under specific conditions
  • Both conductors, with no exception ever permitted
  • No conductor, DC generators are exempt entirely
  • The equipment grounding conductor only

NEC Reference: NEC 445.12(D)

Question 26: Dry-type transformers installed indoors and rated over 112.5 kVA must be separated from combustible material by a minimum of:

  • 12 inches
  • 1 inch
  • 6 feet
  • No clearance is required

NEC Reference: NEC 450.21(A)

Question 27: Switches, circuit breakers, and motor controllers installed in a Class I, Division 1 location, with contacts that may produce arcs, must be provided with enclosures that are:

  • Identified/approved for the specific class and group (explosionproof)
  • Standard indoor plastic enclosures
  • Open, without any enclosure
  • Cardboard boxes for cost savings

NEC Reference: NEC 501.115(A)

Question 28: Listed or labeled equipment must be installed and used in accordance with:

  • Any instructions included in the listing or labeling
  • Whatever the installer prefers, ignoring instructions
  • No instructions ever apply
  • Only verbal instructions from the inspector

NEC Reference: NEC 110.3(B)

Question 29: Electrical equipment must be installed in a:

  • Neat and workmanlike manner
  • Any manner, quality is not addressed
  • Hidden manner only, regardless of quality
  • The fastest manner possible, regardless of appearance

NEC Reference: NEC 110.12

Question 30: The NEC is intended to be enforced and interpreted by the:

  • Authority having jurisdiction (AHJ)
  • Any homeowner, without qualification
  • No one, it is purely advisory
  • The equipment manufacturer only

NEC Reference: NEC 90.4

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)