NEC 2020 Code Questions Practice Test 12

Free NEC 2020 practice test with 30 questions on branch circuits, GFCI locations, load calculations, and box fill. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2020 Code Questions Practice Test 12 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2020
NEC 2020 Code Questions Practice Test 12
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2020 Code Questions Practice Test 12 — Question List

Question 1: A branch circuit with two or more ungrounded conductors and a shared neutral is called a:

  • Multiwire branch circuit
  • Feeder
  • Service lateral
  • Tap conductor

NEC Reference: NEC Article 100

Question 2: A dwelling bathroom must have at least one 20 ampere branch circuit that supplies:

  • Only bathroom receptacle outlets
  • The whole house lighting
  • The kitchen and bathroom together
  • The garage

NEC Reference: NEC 210.11(C)(3)

Question 3: How many 20 ampere small appliance circuits are required in a dwelling kitchen?

  • One
  • Two
  • Three
  • Four

NEC Reference: NEC 210.11(C)(1)

Question 4: A dwelling unit must have at least one dedicated 20 ampere circuit for:

  • The laundry area
  • The living room
  • The attic
  • The garage door opener

NEC Reference: NEC 210.11(C)(2)

Question 5: A branch circuit supplies a continuous load of 16 amperes. What is the minimum conductor ampacity needed?

  • 16 amperes
  • 20 amperes
  • 24 amperes
  • 32 amperes

NEC Reference: NEC 210.19(A)(1)

Question 6: AFCI protection is required for 120 volt, 15 and 20 ampere circuits in a dwelling unit for:

  • Nearly all areas of the dwelling unit
  • Only the garage
  • Only outdoor circuits
  • AFCI is never required

NEC Reference: NEC 210.12(A)

Question 7: All 125 volt, 15 and 20 ampere receptacles in a dwelling bathroom need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A metal cover only

NEC Reference: NEC 210.8(A)(1)

Question 8: Receptacles in a dwelling garage need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A locked cover

NEC Reference: NEC 210.8(A)(2)

Question 9: Outdoor receptacles at a dwelling unit need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A padlock

NEC Reference: NEC 210.8(A)(3)

Question 10: Receptacles in a dwelling crawl space at or below grade need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A dedicated 50 ampere circuit

NEC Reference: NEC 210.8(A)(4)

Question 11: Receptacles in an unfinished basement need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A dedicated neutral

NEC Reference: NEC 210.8(A)(5)

Question 12: Receptacles that serve the kitchen countertop need:

  • GFCI protection
  • No special protection
  • AFCI protection only
  • A dedicated 50 ampere circuit

NEC Reference: NEC 210.8(A)(6)

Question 13: For an interior stairway with six steps or more, a wall switch is needed at:

  • Each floor level
  • Only the top of the stairs
  • Only the bottom of the stairs
  • No switch is needed

NEC Reference: NEC 210.70(A)(2)

Question 14: A dwelling unit has 1000 square feet. What is the general lighting load, using 3 VA per square foot?

  • 1000 VA
  • 2000 VA
  • 3000 VA
  • 4000 VA

NEC Reference: NEC Table 220.12

Question 15: Each small appliance circuit is counted at what load value for service calculations?

  • 500 VA
  • 1000 VA
  • 1500 VA
  • 2000 VA

NEC Reference: NEC 220.52(A)

Question 16: The laundry branch circuit is counted at what load value for service calculations?

  • 500 VA
  • 1000 VA
  • 1500 VA
  • 2500 VA

NEC Reference: NEC 220.52(B)

Question 17: What is the minimum load used for a dwelling clothes dryer, unless the nameplate rating is higher?

  • 3000 watts
  • 4000 watts
  • 5000 watts
  • 6000 watts

NEC Reference: NEC 220.54

Question 18: When only one conductor is placed in a raceway, the maximum fill allowed is:

  • 31 %
  • 40 %
  • 53 %
  • 60 %

NEC Reference: NEC Chapter 9, Table 1

Question 19: When exactly two conductors are placed in a raceway, the maximum fill allowed is:

  • 31 %
  • 40 %
  • 53 %
  • 60 %

NEC Reference: NEC Chapter 9, Table 1

Question 20: Each 14 AWG conductor in a box fill calculation needs a volume allowance of:

  • 1.5 in3
  • 2.0 in3
  • 2.25 in3
  • 2.5 in3

NEC Reference: NEC Table 314.16(B)

Question 21: Each 10 AWG conductor in a box fill calculation needs a volume allowance of:

  • 2.0 in3
  • 2.25 in3
  • 2.5 in3
  • 3.0 in3

NEC Reference: NEC Table 314.16(B)

Question 22: Every circuit at a panelboard must be identified on:

  • A circuit directory
  • Nothing, labels are optional
  • A note left with the seller
  • The electric bill

NEC Reference: NEC 408.4(A)

Question 23: A grounded (neutral) conductor 6 AWG or smaller must be identified by which color?

  • Black
  • White or gray
  • Red
  • Blue

NEC Reference: NEC 200.6(A)

Question 24: An equipment grounding conductor is identified by which color?

  • Green, or green with a yellow stripe
  • Orange
  • White
  • Blue

NEC Reference: NEC 250.119

Question 25: An ungrounded (hot) conductor should not be colored:

  • White or green
  • Black
  • Red
  • Blue

NEC Reference: NEC 200.6

Question 26: A flexible cord must not be used as a substitute for:

  • The fixed wiring of a building
  • A portable lamp
  • A power tool
  • A holiday light string

NEC Reference: NEC 400.12

Question 27: In a dwelling living room, no point along the wall should be more than how far from a receptacle?

  • 4 feet
  • 6 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 210.52(A)(1)

Question 28: A dwelling hallway 10 feet long or more must have at least how many receptacles?

  • None
  • One
  • Two
  • Three

NEC Reference: NEC 210.52(H)

Question 29: A bathroom receptacle must be located within what distance of the outside edge of the basin?

  • 1 foot
  • 3 feet
  • 6 feet
  • 10 feet

NEC Reference: NEC 210.52(D)

Question 30: Tamper-resistant receptacles are required in which dwelling receptacles?

  • Almost all dwelling receptacles
  • Only outdoor receptacles
  • Only garage receptacles
  • None are required

NEC Reference: NEC 406.12