NEC_PRACTICE NEC 2020

NEC 2020 Code Questions Practice Test 15

Free NEC 2020 practice test with 30 questions on grounding electrodes, bonding jumpers, panelboards, and box fill. Plain-English questions with full explanations.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2020 Code Questions Practice Test 15 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2020
NEC 2020 Code Questions Practice Test 15
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2020 Code Questions Practice Test 15 — Question List

Question 1: A concrete-encased electrode (Ufer ground) needs at least 20 feet of steel rebar or bare copper wire, covered by at least how much concrete?

  • 2 inches
  • 1/4 inch
  • 12 inches
  • No cover is stated

NEC Reference: NEC 250.52(A)(3)

Question 2: A metal underground water pipe can be used as a grounding electrode if it is in contact with the earth for at least:

  • 2 feet
  • 10 feet
  • 50 feet
  • Any length

NEC Reference: NEC 250.52(A)(1)

Question 3: When a second (supplemental) ground rod is installed, it must be spaced from the first rod by at least:

  • 2 feet
  • 6 feet
  • 10 feet
  • 20 feet

NEC Reference: NEC 250.53(A)(3)

Question 4: A single ground rod tests at 30 ohms resistance to earth. What must be done?

  • Add a supplemental electrode
  • Nothing further is needed
  • Remove the rod completely
  • Shut off the whole service

NEC Reference: NEC 250.53(A)(2)

Question 5: Where the grounding electrode conductor connects only to a ground rod, it need not be larger than:

  • 6 AWG copper
  • 2/0 AWG copper
  • 14 AWG copper
  • There is no limit

NEC Reference: NEC 250.66(A)

Question 6: A metal raceway that holds a grounding electrode conductor must be:

  • Bonded at both ends
  • Left ungrounded
  • Insulated from the conductor
  • Not permitted at all

NEC Reference: NEC 250.86

Question 7: Metal ductwork that could become energized must be bonded to:

  • The service equipment or grounding system
  • It is never bonded
  • A tree root
  • The phone company

NEC Reference: NEC 250.104(C)

Question 8: Metal gas piping that could become energized must be bonded to:

  • The service equipment or grounding system
  • Nothing, gas pipe is never bonded
  • Only the gas meter
  • The telephone line

NEC Reference: NEC 250.104(B)

Question 9: The grounded (neutral) conductor must be run to each service disconnect and:

  • Bonded to the disconnect
  • Left disconnected
  • Cut short
  • Removed entirely

NEC Reference: NEC 250.24(C)

Question 10: Where several service disconnects share one set of service conductors, the grounded conductor must connect to the grounding electrode system at:

  • Only one point
  • Every disconnect separately
  • It does not matter
  • No connection is made

NEC Reference: NEC 250.24(A)(4)

Question 11: Past the service disconnect, the neutral conductor is generally not permitted to be used to:

  • Ground equipment
  • Carry any current
  • Connect to the panel
  • It has no such rule

NEC Reference: NEC 250.142(B)

Question 12: For a transformer that creates a separately derived system, the system bonding jumper goes at the source or at:

  • The first disconnect, but not both places
  • Every downstream panel
  • It is never required
  • The far end of the circuit only

NEC Reference: NEC 250.30(A)

Question 13: Which of the following is an approved way to make a grounding connection?

  • Exothermic welding
  • Solder alone
  • Tape alone
  • No method is approved

NEC Reference: NEC 250.8

Question 14: Every panelboard must be marked by the maker with the voltage, current rating, and:

  • Number of phases
  • The buyer's address
  • No marking is required
  • The store name

NEC Reference: NEC 408.30

Question 15: Panelboard circuits must be arranged so they do not overload the:

  • Supply conductors or bus
  • Building foundation
  • Owner's budget
  • Nothing, arrangement does not matter

NEC Reference: NEC 408.3(A)

Question 16: For box fill, a switch or receptacle on one strap counts as how many conductors?

  • Zero
  • One
  • Two
  • Four

NEC Reference: NEC 314.16(B)(4)

Question 17: When a box has one or more internal cable clamps, the fill calculation must add:

  • One conductor allowance
  • One allowance per clamp
  • Zero, clamps are not counted
  • Four conductor allowances

NEC Reference: NEC 314.16(B)(3)

Question 18: When several equipment grounding conductors enter a box, they are counted in the fill calculation as:

  • One conductor total
  • Each one counted separately
  • Never counted
  • Two conductors, always

NEC Reference: NEC 314.16(B)(2)

Question 19: In a wall made of wood, an outlet box must be flush or set back from the surface by no more than:

  • 1/4 inch
  • 1 inch
  • 2 inches
  • 1/2 inch

NEC Reference: NEC 314.20

Question 20: For a straight pull, a pull box must be at least how many times the trade size of the largest raceway?

  • 4 times
  • 6 times
  • 8 times
  • 10 times

NEC Reference: NEC 314.28(A)(1)

Question 21: For an angle pull, the pull box distance must be at least how many times the trade size of the largest raceway?

  • 4 times
  • 6 times
  • 8 times
  • 10 times

NEC Reference: NEC 314.28(A)(2)

Question 22: Conductors entering a box must be protected from:

  • Abrasion
  • Nothing, no rule applies
  • Voltage drop
  • Sunlight

NEC Reference: NEC 314.17

Question 23: A raceway is generally not permitted to be used to support:

  • Other raceways or cables
  • Itself
  • Nothing, this is always allowed
  • Light fixtures only

NEC Reference: NEC 300.11(B)

Question 24: All conductors of the same circuit must generally be run:

  • Together in the same raceway or cable
  • In separate raceways
  • It does not matter
  • 6 inches apart, always

NEC Reference: NEC 300.3(B)

Question 25: Where wiring passes through a fire-rated wall, the opening must be sealed to:

  • Keep the fire rating intact
  • Improve air flow
  • Save money on materials
  • It has no purpose

NEC Reference: NEC 300.21

Question 26: A raceway buried underground is treated as a wet location inside. The conductors used inside must be:

  • Listed for wet locations
  • Any dry-location conductor
  • It does not matter
  • Bare, with no insulation

NEC Reference: NEC 300.9

Question 27: An underground raceway entering a building must be sealed to keep out:

  • Moisture and gas
  • Sunlight only
  • Nothing, sealing is optional
  • Noise

NEC Reference: NEC 300.5(G)

Question 28: A raceway runs from a warm indoor space to the cold outdoors. It must be sealed to prevent:

  • Warm air moving to the cold end
  • Electricity from flowing
  • Sound
  • Nothing, it has no purpose

NEC Reference: NEC 300.7(A)

Question 29: A direct-buried cable can be spliced underground without a splice box, if the splice method is:

  • Listed for direct burial
  • Wrapped in tape only
  • Never allowed underground
  • Soldered only

NEC Reference: NEC 300.5(E)

Question 30: What section of the NEC covers rules for direct-buried cable, including depth and protection?

  • NEC 300.5
  • NEC 90.1
  • NEC 110.3
  • No section covers this

NEC Reference: NEC 300.5

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2020
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)