NEC_PRACTICE NEC 2023

NEC 2023 Code Questions Practice Test 1

Free NEC 2023 practice test with 30 questions covering dwelling feeder and service neutral sizing, equipment permitted on the supply side of the service disconnect, grounding and bonding connection methods, recognized equipment grounding conductor types, and box depth rules. Full NEC 2023 references.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 1 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 1
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 1 — Question List

Question 1: If a 115 volts load is connected to 120 v source. what is the minimum voltage that should be supplied to load as recommended by NEC?

  • 114 volts
  • 120 volts
  • 115 volts
  • 118 volts

Question 2: What is the receptacle calculated load for a 18000 square feet commercial property which contains one hundred twenty 15 A and 20 A 120 receptacles?

  • 15800 VA
  • 18000 VA
  • 16800 VA
  • 21500 VA

NEC Reference: NEC 220.14(1)

Question 3: In no case the rating of short  circuit ground fault protective device for a single motor compressor should not exceed ..... percentage of the motor.

  • 175 %
  • 225 %
  • 220 %
  • 150 %

NEC Reference: NEC 440.22(A)

Question 4: The service disconnect for a mobile home should be located not less than ............. feet above platform.

  • 1
  • 2
  • 1/2
  • 3

NEC Reference: NEC 550.32(F)

Question 5: What is the minimum feeder or service load for cloth dryers in a dwelling unit?

  • 5000 watts
  • 2800 watts
  • 4500 watts
  • 6500 watts

NEC Reference: NEC 220.54

Question 6: A 4000 watts electric oven is connected to a 480 volts circuit. What is the resistance of heating element?

  • 57.6 ohms
  • 78.6 ohms
  • 82 ohms
  • 48

Question 7: In a three phase balanced 4-wire system, the current in the neutral conductor ...............................

  • is same as un-grounded conductors
  • is higher than other conductors
  • is lower than other conductors
  • will not flow as the circuit is balanced

Question 8: Which of the following conductors need over current protection on a residential electric service?

  • un-grounded conductor
  • grounded conductor
  • neutral conductor
  • equipment grounding conductor

NEC Reference: NEC 240.15

Question 9: In class I Division 1 location, All fixed boxes and joints should be made ..............

  • explosion proof
  • water proof
  • dust proof
  • fire proof

NEC Reference: NEC 500.7(A)

Question 10: The feeder or service neutral load is generally computed based on the maximum net calculated load between the:

  • Neutral conductor and any one ungrounded conductor
  • Two ungrounded conductors only, ignoring the neutral
  • The ground and the neutral
  • It is always 100% of the total connected load

NEC Reference: NEC 220.61

Question 11: A means must be provided to disconnect all ungrounded conductors of each outside branch circuit or feeder at the point where they:

  • Enter the building or structure
  • Leave the utility pole
  • No disconnect is ever required
  • Cross a property line

NEC Reference: NEC 225.31

Question 12: Which of the following is permitted to be connected on the supply side of the service disconnecting means?

  • A listed surge-protective device
  • A general-purpose lighting panel
  • A branch-circuit receptacle
  • A motor branch circuit

NEC Reference: NEC 230.82

Question 13: Overcurrent devices must be enclosed in cabinets, cutout boxes, or equipment enclosures, unless they are:

  • Part of controllers or assemblies designed for exposed mounting
  • Never permitted to be enclosed
  • Always mounted outdoors uncovered
  • Wrapped in tape only

NEC Reference: NEC 240.30

Question 14: Grounding and bonding connections that are not required to be accessible must be made by which of the following methods, among others listed in the code?

  • Exothermic welding or listed pressure connectors
  • Solder alone
  • Electrical tape alone
  • No connection method is specified

NEC Reference: NEC 250.8

Question 15: NEC 250.118 lists acceptable types of equipment grounding conductors. Which of the following qualifies?

  • Rigid metal conduit
  • A garden hose
  • A telephone line
  • A wood support beam

NEC Reference: NEC 250.118

Question 16: Ferrous metal raceways, cable trays, boxes, and fittings that are to be installed in wet locations must be protected from corrosion by which method?

  • A corrosion-resistant coating, such as galvanizing
  • No protection is required
  • Painting the outside only, with the inside left bare
  • Wrapping in plastic bags

NEC Reference: NEC 300.6

Question 17: Conductor ampacity must be determined either by the tables in Article 310, or by:

  • Engineering supervision using recognized ampacity calculations
  • Guesswork, with no basis needed
  • It cannot be determined any other way
  • The homeowner's preference

NEC Reference: NEC 310.14

Question 18: Outlet, device, and other boxes must have a minimum depth sufficient to accommodate the equipment they enclose, but generally not less than:

  • 1/2 inch
  • 4 inches
  • 1/8 inch
  • There is no minimum

NEC Reference: NEC 314.24

Question 19: Type UF (underground feeder) cable is permitted for use:

  • As direct-buried underground feeder or branch-circuit cable
  • Only above ground indoors
  • It has no permitted use
  • Only for telephone wiring

NEC Reference: NEC 340.10

Question 20: Where flexibility is necessary after installation, flexible metal conduit (FMC) is permitted to be unsupported for a length not exceeding:

  • 3 feet
  • 6 feet
  • 10 feet
  • 12 feet

NEC Reference: NEC 348.30(A)

Question 21: Switches or circuit breakers used as switches must generally be installed so the center of the grip of the operating handle, at its highest position, is not more than:

  • 6 feet 7 inches
  • 4 feet
  • 8 feet
  • There is no height limit

NEC Reference: NEC 404.8(A)

Question 22: Where a receptacle is replaced on a branch circuit that requires AFCI protection, but the panel does not have an AFCI breaker, the replacement receptacle is permitted to be:

  • A listed outlet-branch-circuit AFCI receptacle
  • Any standard non-AFCI receptacle
  • No AFCI protection is ever required for replacements
  • A GFCI receptacle only, ignoring AFCI

NEC Reference: NEC 406.4(D)(4)

Question 23: A recessed luminaire that will be in direct contact with thermal insulation must be listed as Type:

  • Type IC (insulation contact)
  • Type NM
  • Type AC
  • No listing is required

NEC Reference: NEC 410.116(A)

Question 24: A cord-and-plug-connected waste (food) disposer under a sink is permitted to have a flexible cord length within what range?

  • 18 to 36 inches
  • 3 to 6 inches
  • 5 to 8 feet
  • Any length

NEC Reference: NEC 422.16(B)(1)

Question 25: Embedded heating cables for radiant floor heating must not be installed under permanently installed cabinets or where they would be:

  • Beneath permanently installed cabinets
  • Anywhere in an open floor area
  • It may be installed anywhere with no restriction
  • Only near a window

NEC Reference: NEC 424.44(E)

Question 26: A stationary motor rated 1 horsepower or less, normally left running continuously, is permitted to be protected against overload by:

  • The branch-circuit, short-circuit, and ground-fault protective device
  • No protection at all is permitted
  • A separate 400% rated fuse only
  • A padlock on the motor housing

NEC Reference: NEC 430.32(B)

Question 27: Article 440 (Air-Conditioning and Refrigerating Equipment) supplements or amends the general motor rules of Article 430 for equipment using a hermetic motor-compressor. Where Article 440 does not specifically address a topic, which article generally applies?

  • Article 430 (Motors)
  • Article 250 (Grounding)
  • Article 90 only
  • No other article ever applies

NEC Reference: NEC 440.3

Question 28: Guards, isolation by elevation, or an enclosure must be provided to protect employees from live current-carrying generator parts operating at more than:

  • 50 volts
  • 600 volts
  • 12 volts
  • No protection is ever required

NEC Reference: NEC 445.15

Question 29: Exposed non-current-carrying metal parts of a transformer installation, such as the core and case, must be:

  • Grounded, per Article 250
  • Left ungrounded intentionally
  • Painted for identification only
  • It does not matter

NEC Reference: NEC 450.10

Question 30: In a Class II, Division 1 location, combustible dust is present in the air under normal operating conditions in quantities sufficient to produce:

  • Explosive or ignitible mixtures
  • No hazard at all
  • Only cosmetic dust buildup
  • Static discharge with no fire risk

NEC Reference: NEC 500.5(C)(1)

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)