NEC_PRACTICE NEC 2023

NEC 2023 Code Questions Practice Test 9

Free NEC 2023 practice test with 30 questions covering grounding electrode conductor sizing caps, required outdoor dwelling receptacles, the small conductor overcurrent rule, bonding of metal piping systems, and motor location/ventilation requirements. Full NEC 2023 references included.

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC 2023 Code Questions Practice Test 9 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC 2023 Code Questions Practice Test 9
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2023 Code Questions Practice Test 9 — Question List

Question 1: What is the maximum voltage drop that is recommended by NEC for branch conductor and feeder conductor?

  • 3 %
  • 5 %
  • 8 %
  • 4 %

NEC Reference: NEC 210.19(A) / 215.2(A) Informational Notes

Question 2: What is the minimum load that is required for exterior sign or outline lightening for a commercial occupancy as per NEC?

  • 12000 VA
  • 18000 VA
  • 15000 VA
  • 21000 VA

NEC Reference: NEC 220.14(F)

Question 3: A cord and plug device used as disconnecting means for a motor must be rated for ..................

  • Horsepower
  • voltage
  • Resistance
  • Current

NEC Reference: NEC 430.109(F)

Question 4: A 2400 volts motor disconnecting means must be capable of being locked in the .....................

  • closed position
  • Open position
  • ON position
  • Both open and close position

NEC Reference: NEC 430.227

Question 5: If the branch circuit rating more than ................., the lamp holders connected to it should be of the heavy duty type.

  • 20 amperes
  • 25 amperes
  • 40 amperes
  • 45 amperes

NEC Reference: NEC 210.21(A)

Question 6: All 15 or 20 amperes receptacle outlets installed in bathrooms of dwelling units must always require .............................

  • Non ground recetacles
  • water proof receptacles
  • protective gaurds
  • Ground fault circuit interceptor ( GFCI)

NEC Reference: NEC 210.8(A)(1)

Question 7: How much power consumed by 240 volts circuit that draws 30 amperes current?

  • 7.2 KW
  • 5.2 KW
  • 8.5 KW
  • 9.3 KW

Question 8: For conductors supplying portable signs in a dry location what is the maximum length in feet allowed?

  • 16
  • 12
  • 15
  • 8

NEC Reference: NEC 600.10(D)(2)

Question 9: For a commercial kitchen with two electrical equipment, what demand factor is allowed?

  • 100 %
  • 80 %
  • 70 %
  • 90 %

NEC Reference: NEC 220.56

Question 10: Where the grounding electrode conductor connects only to a rod, pipe, or plate electrode (or a combination of these), the conductor is not required to be larger than:

  • 6 AWG copper
  • 2/0 AWG copper
  • 14 AWG copper
  • There is no maximum size cap

NEC Reference: NEC 250.66(A)

Question 11: A one-family dwelling must have at least one receptacle outlet accessible at grade level installed:

  • At both the front and back of the dwelling
  • Only inside the garage
  • Nowhere outdoors, it is not required
  • Only on the roof

NEC Reference: NEC 210.52(E)(1)

Question 12: Under the small conductor rule, 12 AWG copper conductors are limited to a maximum standard overcurrent device rating of:

  • 20 amperes
  • 15 amperes
  • 30 amperes
  • 40 amperes

NEC Reference: NEC 240.4(D)(5)

Question 13: Metal piping systems (other than gas piping), such as ductwork, that may become energized must be bonded per:

  • The service equipment or grounding electrode system
  • It is never bonded
  • Only to a nearby tree root system
  • To the telephone company only

NEC Reference: NEC 250.104(C)

Question 14: Boxes and conduit bodies must be installed so that the wiring contained in them can be rendered accessible without:

  • Removing part of the building structure or finish
  • This is never a requirement
  • Demolishing the entire wall
  • It does not matter if boxes are ever accessible

NEC Reference: NEC 314.29

Question 15: Threadless couplings and connectors used with rigid metal conduit must be:

  • Made up tight, and listed for wet locations where applicable
  • Left loose for thermal expansion
  • Never permitted on RMC
  • Made of plastic only

NEC Reference: NEC 344.42

Question 16: A portable handlamp must be equipped with a flexible cord of the hard-usage or extra-hard-usage type, and:

  • A substantial guard around the lamp
  • No guard is ever required
  • A lightweight paper shade only
  • A second, unused cord

NEC Reference: NEC 410.62(C)

Question 17: A cord-and-plug-connected electric drinking fountain must be provided with:

  • GFCI protection
  • No protection is required
  • AFCI protection only
  • A dedicated 50 ampere circuit only

NEC Reference: NEC 422.52

Question 18: Motors must be located so that adequate ventilation is provided, and so that maintenance, such as lubrication and replacement, can be:

  • Readily accomplished
  • Never performed under any condition
  • It has no bearing on motor location
  • Performed only by the manufacturer, on-site is prohibited

NEC Reference: NEC 430.14(A)

Question 19: A power conversion equipment (adjustable-speed drive) system must provide motor overload protection in one of two ways: by a separate overload device, or by:

  • An integrated overload protection system meeting listed criteria
  • No overload protection is required with a drive
  • A padlock on the drive enclosure
  • The drive's power cord alone

NEC Reference: NEC 430.126

Question 20: A dry-type transformer installed outdoors must have a:

  • Weatherproof enclosure
  • Open frame with no enclosure
  • Wooden crate
  • It does not require any enclosure outdoors

NEC Reference: NEC 450.22

Question 21: Attachment plugs and receptacles in a Class I, Division 2 location must be designed so that connection or disconnection under load:

  • Does not expose live parts, unless listed for the location
  • Is always permitted with no restriction
  • Is prohibited entirely, with no exceptions
  • Has no bearing on hazardous location safety

NEC Reference: NEC 501.105(B)(2)

Question 22: Switches, circuit breakers, and motor controllers with contacts that may produce arcs, installed in a Class II, Division 1 location, must be provided with enclosures that are:

  • Dust-ignitionproof
  • Standard indoor plastic enclosures
  • Open, with no enclosure at all
  • Cardboard, for cost savings

NEC Reference: NEC 502.115(A)

Question 23: In a mobile or manufactured home, GFCI protection is required for 125 volt, 15 and 20 ampere receptacles in which locations, similar to a dwelling unit?

  • Bathrooms, kitchens, and outdoors
  • Nowhere, mobile homes are exempt
  • Only the living room
  • Only the master bedroom

NEC Reference: NEC 550.25

Question 24: The "electrical datum plane" concept at marinas and boatyards is used to determine the minimum elevation above high water for the mounting height of:

  • Electrical equipment
  • Boat hull paint
  • Nothing electrical, only dock decking
  • Fish feeding stations

NEC Reference: NEC 555.19

Question 25: The disconnecting means for elevator, escalator, or moving walk equipment must be legibly marked to indicate:

  • The equipment it controls
  • The installer's favorite color
  • Nothing, marking is optional
  • The building's square footage

NEC Reference: NEC 620.51(D)

Question 26: Automatic transfer switches for emergency systems must be designed and installed to prevent the inadvertent interconnection of:

  • Normal and alternate power sources
  • Two lighting circuits only
  • It has no such purpose
  • Telephone and data circuits only

NEC Reference: NEC 700.6

Question 27: Products listed by a qualified testing laboratory are generally considered to comply with the NEC as-is, and further field inspection of internal wiring is not usually required, per:

  • NEC 90.7
  • NEC 90.1
  • NEC 300.1
  • No such provision exists

NEC Reference: NEC 90.7

Question 28: Each disconnecting means must be legibly marked to indicate its purpose, unless:

  • The purpose is evident by the physical arrangement
  • Marking is never required, regardless of context
  • It is always required, with no exceptions ever
  • Marking is optional at the installer's convenience

NEC Reference: NEC 110.22(A)

Question 29: Where circuit breakers are applied in a tested series combination rating (higher than the individual interrupting rating alone), the equipment enclosure must be legibly marked to indicate:

  • The series combination rating used
  • Nothing, marking is never required
  • Only the installer's name
  • The building's square footage

NEC Reference: NEC 240.86(C)

Question 30: Normally non-current-carrying conductive materials enclosing electrical conductors must be connected together and to the supply source in a manner that establishes an effective path for fault current, which is intended to:

  • Facilitate overcurrent device operation and limit voltage on equipment
  • Increase the resistance of the circuit intentionally
  • It has no protective purpose
  • Only improve the appearance of the installation

NEC Reference: NEC 250.4(A)(3)