NEC Code Questions Practice Test-8
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-8 — Question List

Question 1: What is the minimum fixture wire size that shall be permitted?

  • 12 AWG
  • 14 AWG
  • 16 AWG
  • 18 AWG

NEC Reference: NEC 402.6

Question 2: What size of over current protection device is required for a 24 ampere continuous load where the ambient temperature is 75 <sup>0</sup>C?

  • 30 amperes
  • 24 amperes
  • 28 ampers
  • 26 amperes

NEC Reference: NEC 210.20(A)

Question 3: In multiple parallel circuit paths, the current will always take the path of ...............

  • least resistance
  • high resistance
  • high voltage
  • low voltage

Question 4: As mentioned in NEC, a multifamily dwelling unit is the one that contains …………….

  • Two or more dwelling units
  • Three or more dwelling units
  • More than one dwelling unit
  • More than two dwelling units

Question 5: What size service conductors are required for a dwelling load with a calculated load is 190 A. The service disconnect breaker is rated at 200 A?

  • 1/0 AWG
  • 2/0 AWG
  • 3/0 AWG
  • 4/0 AWG

NEC Reference: NEC 310.15(B)(16)

Question 6: A 400 breaker protects a set of 450 kcmil feeder conductors. A feeder fed from 450 kcmil feeder that supply disconnects with 25 A over current device. What is the minimum size conductor for these tap?

  • 8 AWG
  • 6 AWG
  • 4 AWG
  • 16 AWG

NEC Reference: NEC 310.15(B)(16)

Question 7: Which is the minimum size copper conductor is required for the grounding electrode conductor (GEC) connected to a ground rod

  • 6 AWG
  • 8 AWG
  • 4 AWG
  • 16 AWG

NEC Reference: NEC 250.166(A)

Question 8: What is the maximum size over current device is required for a 4200 W, 240 V electric water heater connected in a building.

  • 25 A
  • 30 A
  • 35 A
  • 40 A

NEC Reference: NEC 26.25

Question 9: What is the maximum allowable conductor fill for 4in * 4 in wireway?

  • 16 sq in
  • 8 sq in
  • 3.2 sq in
  • 4.8 sq in

NEC Reference: NEC 376.22(A)

Question 10: How many 10 AWG RHH conductors can be installed in trade size ¾ EMT?

  • 3 conductors
  • 5 conductors
  • 6 conductors