NEC_PRACTICE NEC 2023

NEC Code Questions Practice Test-6

Free NEC code Questions Practice Test-6

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 15 min for 10 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
10
Questions
15 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-6
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-6 — Question List

Question 1: What is the minimum size of aluminium conductor used for surge protective devices?

  • 12 AWG
  • 14 AWG
  • 10 AWG
  • 8 AWG

Question 2: Which of the following is the standard fuse rating of an electrical fuse as per NEC?

  • 45
  • 50
  • 55
  • 60

Question 3: Without applying any de-rating factor for conductor current carrying capacity, how many conductors can run parallel in raceway or cable?

  • 4
  • 3
  • 5
  • 6

NEC Reference: NEC 310.15(B)(3)(a)

Question 4: A 120 volts panel has a rating of 50A. What is its maximum over current device rating?

  • 50 A
  • 62.5 A
  • 57.5 A
  • 75 A

Question 5: Which of the following is maximum operating voltage of a low voltage lighting system?

  • 30 volts
  • 25 volts
  • 40 volts
  • 35 volts

NEC Reference: NEC 411.2

Question 6: The standby power shall be available not more than ……………..

  • 30 seconds
  • 75 seconds
  • 1 minute
  • 2 minute

NEC Reference: NEC 701.11

Question 7: In class I division 2 location, unless it is specified the cross sectional area of the conductors permitted in a seal shall not exceed …………. percentage of a cross sectional area of RMC

  • 25
  • 30
  • 40
  • 50

NEC Reference: NEC 501.15(C)(6)

Question 8: Branch circuits for heating and air conditioning equipment located in the elevators shall not exceed which of the following voltage?

  • 600 volts
  • 480 volts
  • 240 volts
  • 900 volts

NEC Reference: NEC 620.3(C)

Question 9: What is the minimum volume allowance required per a No 14 AWG conductor?

  • 1.50 in<sup>3</sup>
  • 1.75 in<sup>3</sup>
  • 2.0 in<sup>3</sup>
  • 2.5 in<sup>3</sup>

NEC Reference: NEC 314.16(B)

Question 10: Mutli-wire branch circuits shall not be permitted in class I division I locations.

  • True
  • False

NEC Reference: NEC 501.40