NEC Code Questions Practice Test-5
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-5 — Question List

Question 1: A single family dwelling unit has a connected load of 4000 VA. which of the following is the calculated demand load?

  • 3350 VA
  • 3550 VA
  • 4000 VA
  • 3850 VA

NEC Reference: NEC 220.42

Question 2: What is the adjustment ampacity of a 3/0 THWN conductor at an ambient temperature of 108<sup>0</sup>F in wet location. The raceway contains four 3/0 THWN conductors in it.

  • 119 amperes
  • 144 amperes
  • 153 amperes
  • 133 amperes

NEC Reference: NEC 310.15(B)(16)

Question 3: In a dwelling unit has an electric heater rated at 5040 watts at 240 volts. What of the circuit breaker is used to protect the circuit?

  • 20 amperes
  • 21 amperes
  • 24 amperes
  • 25 ampere

Question 4: Which of the following locations type NM cable can be permitted to use?

  • As a service entrance cable
  • In storage battery rooms
  • In elevators or escalators
  • one and two family dwelling units

NEC Reference: NEC 334.12

Question 5: In an underground service a bare neutral conductor can be buried in the ground with out any insulation.

  • True
  • False

NEC Reference: NEC 230.30

Question 6: When two or more single phase electric ranges are supplied by a 3 phase , 4 wire feeder, the total load computed is on the basis of ………………………….

  • Twice the maximum number connected between any two phases
  • Four times the maximum number connected between any two phases
  • Three times the maximum number connected to a single phase

NEC Reference: NEC 250.55

Question 7: What is the unit load per square foot in volt ampere for a restaurant?

  • 2 VA
  • 1 VA
  • 3 VA
  • 1 1/2 VA

NEC Reference: NEC 220.12

Question 8: What is permissible voltage drop in percentage for feeders at the farthest outlet of power heating and lighting loads?

  • 3 %
  • 2 %
  • 4 %
  • 5 %

NEC Reference: NEC 215.2(A)(4)

Question 9: At least one 15 or 20 ampere receptacle should be located within 50 feet of electrical service applies to outdoor service equipment.

  • True
  • False

Question 10: The overall length of the power supply cards for mobile homes shall not be less than ………… feet

  • 20 feet
  • 36 ½ feet
  • 25 feet
  • 34 feet

NEC Reference: NEC 550.10(D)