How to Use This Practice Test

This NEC Code Questions Practice Test-3 has 10 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 10 multiple-choice, one correct answer each
10
Questions
15 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-3
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-3 — Question List

Question 1: The rated ampacity of a 1/0 THWN in a wet location is 150 amperes. If the same conductor is operated at ambient temperature of 40<sup>0</sup>C. What is its corrected ampacity?

  • 132 amperes
  • 150 amperes
  • 142 amperes
  • 138 amperes

Question 2: When eight three wire type AC cables are bundled in a raceway of length more than 24 inch. what is the adjustment factor that must be applied?

  • 60 %
  • 70 %
  • 80 %
  • 90 %

Question 3: The flexible cords employed for pool associated motors shall not exceed ………….. feet in length.

  • 3
  • 5
  • 8
  • 12

NEC Reference: NEC 680.21

Question 4: Whether by receptacle or direct connection the outlets supplying pool pump motors shall be provided with …………………………………… protection

  • Over Current
  • GFCI
  • Over voltage

NEC Reference: NEC 680.21(C)

Question 5: When a conduit run passing from a Class I , Division 2 location into a unclassified location must have seal located with …………….. feet of the boundary.

  • 10
  • 15
  • 20
  • 8

NEC Reference: NEC 501.15

Question 6: If a panel board is supplied by a transformer. The over current device must be located ............. side of the transformer

  • Primary Side
  • Secondary Side

Question 7: Which of the following is the maximum rating of a branch circuit that supply the primary of low voltage lighting system power supply?

  • 20 amperes
  • 25 amperes
  • 15 amperes
  • 30 amperes

NEC Reference: NEC 411.6

Question 8: A lighting unit is connected on a 20 ampere branch circuit on which a fastened-in place appliance is located. What is the maximum percentage branch circuit rating is permitted on the appliance?

  • 50 %
  • 75 %
  • 60 %
  • 40 %

NEC Reference: NEC 210.23(A)(2)

Question 9: Which of the following is the smallest size wire permitted for a feeder circuit?

  • No 10 AWG
  • No 12 AWG
  • No 14 AWG
  • No 8 AWG

Question 10: When two or more single phase electric ranges are supplied by a 3 phase , 4 wire feeder, the total load computed is on the basis of ………………………….

  • Twice the maximum number connected between any two phases
  • Four times the maximum number connected between any two phases
  • Three times the maximum number connected to a single phase

NEC Reference: NEC 250.55

EXAM CARD NEC_PRACTICE
Questions10
Time limit15 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026