NEC Code Questions Practice Test-20

Take a Practice test on NEC Code Practice quiz questions - 20

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 14 min for 9 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
9
Questions
14 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-20
Q1 / 9
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-20 — Question List

Question 1: What is the maximum voltage drop that is recommended by NEC for branch conductor and feeder conductor?

  • 3 %
  • 5 %
  • 8 %
  • 4 %

Question 2: What is the minimum load that is required for exterior sign or outline lightening for a commercial occupancy as per NEC?

  • 12000 VA
  • 18000 VA
  • 15000 VA
  • 21000 VA

NEC Reference: NEC 220.14(F)

Question 3: A cord and plug device used as disconnecting means for a motor must be rated for ..................

  • Horsepower
  • voltage
  • Resistance
  • Current

NEC Reference: NEC 430.109(F)

Question 4: A 2400 volts motor disconnecting means must be capable of being locked in the .....................

  • closed position
  • Open position
  • ON position
  • Both open and close position

NEC Reference: NEC 430.227

Question 5: If the branch circuit rating more than ................., the lamp holders connected to it should be of the heavy duty type.

  • 20 amperes
  • 25 amperes
  • 40 amperes
  • 45 amperes

NEC Reference: NEC 210.21(A)

Question 6: All 15 or 20 amperes receptacle outlets installed in bathrooms of dwelling units must always require .............................

  • Non ground recetacles
  • water proof receptacles
  • protective gaurds
  • Ground fault circuit interceptor ( GFCI)

NEC Reference: NEC 210.8(A)(1)

Question 7: How much power consumed by 240 volts circuit that draws 30 amperes current?

  • 7.2 KW
  • 5.2 KW
  • 8.5 KW
  • 9.3 KW

Question 8: For conductors supplying portable signs in a dry location what is the maximum length in feet allowed?

  • 16
  • 12
  • 15
  • 8

NEC Reference: NEC 600.10(D)(2)

Question 9: For a commercial kitchen with two electrical equipment, what demand factor is allowed?

  • 100 %
  • 80 %
  • 70 %
  • 90 %

NEC Reference: NEC 220.56