NEC_PRACTICE NEC 2023

NEC Code Questions Practice Test-15

Take a Practice test on NEC Code Practice quiz questions - 15

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 15 min for 10 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

How to Use This Practice Test

This NEC Code Questions Practice Test-15 has 10 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: Mixed-format test — questions jump between topics just like the real exam. Don't spend more than 90 seconds on any one question.

  • Topics covered: All NEC chapters — branch circuits, grounding, conductors, wiring methods, motors, and more.
  • Passing score: Aim for 80%+ consistently before scheduling your exam.
  • Questions: 10 multiple-choice, one correct answer each
10
Questions
15 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-15
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-15 — Question List

Question 1: What is the maximum voltage drop recommended by NEC for both branch conductor and feeder conductor?

  • 3 %
  • 4 %
  • 5 %
  • 6 %

Question 2: The connected load of all-electric restaurant is 140 KVA which is supplied by a 120/208 V three phase supply. What is the required service conductor ampacity?

  • 311 amperes
  • 538 amperes
  • 423 amperes
  • 621 amperes

NEC Reference: NEC 220.88

Question 3: What size branch circuit protection is required for 20 A motor compressor connected to 240 volts single phase supply?

  • 35 amperes
  • 20 amperes
  • 25 amperes
  • 30 amperes

NEC Reference: NEC 440.22(A)

Question 4: A 30 ampere branch circuit with heavy duty lamp holders is permitted to supply fixed lightening units in .......................

  • single family dwelling unit
  • multi family dwelling unit
  • any occupancy
  • any occupancy other than dwelling unit

NEC Reference: NEC 210.23(B)

Question 5: What is the minimum general lightening load required for 1500 square foot single family dwelling unit as permitted by NEC?

  • 4500 VA
  • 4800 VA
  • 3000 VA
  • 1500 VA

NEC Reference: NEC 220.12

Question 6: What size service conductor is required for a 120/240 volts single phase with a demand load of 48 KVA?

  • 200 amperes
  • 150 amperes
  • 100 amperes
  • 250 amperes

Question 7: In calculating the load for a commercial kitchen with one electric appliance, which of the following demand factor is allowed?

  • 100%
  • 80%
  • 90%
  • 75%

NEC Reference: NEC 220.56

Question 8: The  ampacity of 2/0 THHN conductor is 195 amperes ( 90<sup>0</sup> C). What is the maximum allowable ampacity of 2/0 THHN conductor in a conduit with 5 other current carrying conductors?

  • 156 amperes
  • 136 amperes
  • 195 amperes
  • 185 amperes

NEC Reference: NEC 310.15(B)(3)

Question 9: An isolated ground receptacle shall be identified by :................

  • An orange triangle
  • A permanent seal
  • A green dot
  • A cross sign

NEC Reference: NEC 406.3(D)

Question 10: If a panel board contains a snap switch with rating of 30 amperes must be protected not in excess of :

  • 200 amperes
  • 30 amperes
  • 150 amperes
  • 300 amperes

NEC Reference: NEC 408.36(A)

EXAM CARD NEC_PRACTICE
Questions10
Time limit15 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)