NEC_PRACTICE NEC 2023

NEC Code Questions Practice Test-19

Take a Practice test on NEC Code Practice quiz questions - 19

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 14 min for 9 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
9
Questions
14 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-19
Q1 / 9
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-19 — Question List

Question 1: What is the maximum 3 phase load that can be connected on a 220 ft 8 THWN , 480 volts conductor without exceeding the NEC recommended voltage drop?

  • 40 KVA
  • 45 KVA
  • 48 KVA
  • 44 KVA

NEC Reference: NEC 14.4

Question 2: What is the minimum general lighting load required for a 1500 square feet ware house as permitted by NEC?

  • 375 VA
  • 1500 VA
  • 585 VA
  • 1245 VA

Question 3: A 240 volts single phase room air-conditioner rating not more than ............. can be consider as a single motor unit?

  • 30 amperes
  • 40 amperes
  • 50 amperes
  • 60 amperes

NEC Reference: NEC 440.62(A)(2)

Question 4: If a replacement motor compressor draws 48 amperes , what s the minimum rating of disconnect means?

  • 46 amperes
  • 40 amperes
  • 50 amperes
  • 44 amperes

NEC Reference: NEC 440.12(A)(1)

Question 5: The single phase switches can be used to control the motors when they are rated at ......... horse power or less.

  • 1/2
  • 1/4
  • 3/4
  • 1

Question 6: What should be the maximum percentage cross sectional area of a conduit that should be occupied when three or more THW conductors are placed in a conduit?

  • 40 %
  • 25 %
  • 30 %
  • 45 %

Question 7: What is the resistance offered by electric heater rated 1800 watts at 120 volts?

  • 8 ohms
  • 15 ohms
  • 6 ohms
  • 12 ohms

Question 8: Intrinsically safe conductors are identified by ..............

  • red
  • black
  • blue
  • brown

NEC Reference: NEC 504.80(C)

Question 9: Which of the following is the smallest conductor permitted for pool equipment is :

  • 8 AWG
  • 12 AWG
  • 10 AWG
  • 6 AWG

NEC Reference: NEC 680.26(B)