NEC_PRACTICE NEC 2023

NEC Code Questions Practice Test-16

Take a Practice test on NEC Code Practice quiz questions - 16

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 12 min for 8 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
8
Questions
12 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-16
Q1 / 8
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-16 — Question List

Question 1: What is the maximum voltage drop in branch conductor recommended by NEC ?

  • 2 %
  • 3 %
  • 5 %
  • 6 %

Question 2: what is the minimum general lightening load required for 3500 square foot ware house as permitted by NEC ?

  • 700 VA
  • 3500 VA
  • 7000 VA
  • 4500 VA

NEC Reference: NEC 220.12

Question 3: If a 20 ampere AC snap switch is used to disconnect a 1.5 HP motor what must be the maximum full load current of a motor?

  • 16 amperes
  • 20 amperes
  • 15 amperes
  • 17 amperes

NEC Reference: NEC 430.109(C)(2)

Question 4: What is the maximum continuous load that can be connected to 240 volts 20 ampere branch circuit?

  • 16 amperes
  • 20 amperes
  • 14 amperes
  • 10 amperes

NEC Reference: NEC 210.20

Question 5: In a single family dwelling unit when four or more appliances are fastened in a place and connected to the same feeder then ....... percent demand factor can be applied in calculating total demand load.

  • 75
  • 85
  • 83
  • 90

Question 6: What is the the minimum size copper wire that can be used for outside overhead wiring, if the wire carries more than 600 volts?

  • No. 6 AWG
  • No. 8 AWG
  • No. 10 AWG
  • No. 12 AWG

NEC Reference: NEC 225.6(A)(2)

Question 7: What is the maximum allowable voltage between two adjacent snap switches are receptacles placed in a enclosure?

  • 300 volts
  • 240 volts
  • 480 volts
  • 120 volts

NEC Reference: NEC 404.8(B)

Question 8: Which of the following is the smallest size fixture wire allowed?

  • No . 18 AWG
  • No . 12 AWG
  • No . 14 AWG
  • No . 20 AWG

NEC Reference: NEC 410.54(B)

EXAM CARD NEC_PRACTICE
Questions8
Time limit12 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate

Timer starts immediately. Progress is auto-saved.