NEC_PRACTICE NEC 2023

NEC Code Questions Practice Test-12

Take a Practice test on NEC Code Practice quiz questions - 12

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 14 min for 9 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
9
Questions
14 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2023
NEC Code Questions Practice Test-12
Q1 / 9
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-12 — Question List

Question 1: If a 115 volts load is connected to 120 v source. what is the minimum voltage that should be supplied to load as recommended by NEC?

  • 114 volts
  • 120 volts
  • 115 volts
  • 118 volts

Question 2: What is the receptacle calculated load for a 18000 square feet commercial property which contains one hundred twenty 15 A and 20 A 120 receptacles?

  • 15800 VA
  • 18000 VA
  • 16800 VA
  • 21500 VA

NEC Reference: NEC 220.14(1)

Question 3: In no case the rating of short  circuit ground fault protective device for a single motor compressor should not exceed ..... percentage of the motor.

  • 175 %
  • 225 %
  • 220 %
  • 150 %

NEC Reference: NEC 440.22(A)

Question 4: The service disconnect for a mobile home should be located not less than ............. feet above platform.

  • 1
  • 2
  • 1/2
  • 3

NEC Reference: NEC 550.32(F)

Question 5: What is the minimum feeder or service load for cloth dryers in a dwelling unit?

  • 5000 watts
  • 2800 watts
  • 4500 watts
  • 6500 watts

NEC Reference: NEC 220.54

Question 6: A 4000 watts electric oven is connected to a 480 volts circuit. What is the resistance of heating element?

  • 57.6 ohms
  • 78.6 ohms
  • 82 ohms
  • 48

NEC Reference: NEC 57.6

Question 7: In a three phase balanced 4-wire system, the current in the neutral conductor ...............................

  • is same as un-grounded conductors
  • is higher than other conductors
  • is lower than other conductors
  • will not flow as the circuit is balanced

Question 8: Which of the following conductors need over current protection on a residential electric service?

  • un-grounded conductor
  • grounded conductor
  • neutral conductor
  • equipment grounding conductor

NEC Reference: NEC 240.15

Question 9: In class I Division 1 location, All fixed boxes and joints should be made ..............

  • explosion proof
  • water proof
  • dust proof
  • fire proof

NEC Reference: NEC 500.7(A)

EXAM CARD NEC_PRACTICE
Questions9
Time limit14 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate

Timer starts immediately. Progress is auto-saved.