NEC Questions Practice Test-12
Quiz-summary
0 of 9 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
Information
Take a Practice test on NEC Code Practice quiz questions – 12
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading...
You must sign in or sign up to start the quiz.
You have to finish following quiz, to start this quiz:
Results
0 of 9 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 points, (0)
Average score |
|
Your score |
|
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- Answered
- Review
-
Question 1 of 9
1. Question
1 pointsIf a 115 volts load is connected to 120 v source. what is the minimum voltage that should be supplied to load as recommended by NEC?
Correct
Incorrect
NEC recommended that the maximum voltage drop should be 5% for both branch circuit and feeder circuit.
120 * 0.05 = 6 volts
so minimum voltage supplied to load = 120 – 6 = 114 volts;
-
Question 2 of 9
2. Question
1 pointsWhat is the receptacle calculated load for a 18000 square feet commercial property which contains one hundred twenty 15 A and 20 A 120 receptacles?
Correct
Incorrect
Refer: NEC 220.14(1)
For each receptacle the minimum load is 180 VA
Total load = 120 * 180 = 21600 VA
Refer NEC Table 220.44
First 10,000 at 100 % = 10000 * 1 = 10000 VA
Remaining at 50% = 11600 * 0.5 = 5800 VA
Total Calculated Load = 15800 VA
-
Question 3 of 9
3. Question
1 pointsIn no case the rating of short circuit ground fault protective device for a single motor compressor should not exceed ….. percentage of the motor.
Correct
Incorrect
Refer : NEC 440.22 (A)
-
Question 4 of 9
4. Question
1 pointsThe service disconnect for a mobile home should be located not less than …………. feet above platform.
Correct
Incorrect
Refer : NEC 550.32(F)
-
Question 5 of 9
5. Question
1 pointsWhat is the minimum feeder or service load for cloth dryers in a dwelling unit?
Correct
Incorrect
Refer : NEC 220.54
-
Question 6 of 9
6. Question
1 pointsA 4000 watts electric oven is connected to a 480 volts circuit. What is the resistance of heating element?
Correct
Incorrect
P = E2 / R
R = P2 / E = (480 * 480 ) / 4000 = 57.6 ohms
-
Question 7 of 9
7. Question
1 pointsIn a three phase balanced 4-wire system, the current in the neutral conductor ………………………….
Correct
Incorrect
-
Question 8 of 9
8. Question
1 pointsWhich of the following conductors need over current protection on a residential electric service?
Correct
Incorrect
Refer: NEC 240.15
-
Question 9 of 9
9. Question
1 pointsIn class I Division 1 location, All fixed boxes and joints should be made …………..
Correct
Incorrect
Refer : NEC 500.7 (A)