NEC_PRACTICE NEC 2026

NEC 2026 Code Questions Practice Test 2

Free NEC 2026 practice test with 30 questions on branch circuits: required dwelling circuits, receptacle spacing and locations, AFCI protection, multiwire circuits, receptacle ratings and Article 406 rules for tamper-resistant and weather-resistant receptacles.

Share this test
Want the real exam format? Take a free full-length exam for your state
TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Before You Start

  • 30 questions, multiple choice
  • 45 minutes, pass mark 70%
  • Main articles: 210 and 406

Tip: Learn the dwelling receptacle "distances": 6 ft / 12 ft wall spacing, 24 in countertop, 3 ft from a bathroom basin, 6½ ft outdoor height, 25 ft HVAC service receptacle.

30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2026
NEC 2026 Code Questions Practice Test 2
Q1 / 30
--:-- ON PACE
Auto-save 0% complete
0%
your score

0
Correct
0
Wrong
0
Skipped
0s
Time
How was this test?
Rate it and add a quick comment. No sign-up.
Tap one to send it now:
Share your score
Share it and get the NEC 2026 Article Quick Reference free, right now.
Unlocked — thanks for sharing! 🎉
Get the NEC 2026 Article Quick Reference
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2026 Code Questions Practice Test 2 — Question List

Question 1: Per NEC 210.11(C)(1), a dwelling unit must have at least how many 20-ampere small-appliance branch circuits for kitchen, pantry, breakfast room and dining room receptacles?

  • Four
  • Two
  • One
  • Three

NEC Reference: NEC 2026 — 210.11(C)(1)

Question 2: Per NEC 210.11(C)(3), at least one 20-ampere branch circuit must be provided to supply bathroom receptacle outlets. This circuit:

  • Must be rated 15 amperes and supply only one bathroom
  • May supply receptacles in any room of the dwelling unit
  • Must also supply the laundry receptacle outlets in the same dwelling
  • May not supply other outlets, except it may supply the other loads in a single bathroom

NEC Reference: NEC 2026 — 210.11(C)(3)

Question 3: Per NEC 210.11(C)(4), a dwelling with an attached garage must have at least one 120-volt, 20-ampere branch circuit to supply:

  • A 240-volt receptacle for an electric vehicle charger
  • Receptacle outlets in the garage (and readily accessible outdoor receptacle outlets)
  • The garage lighting and the kitchen countertop receptacles
  • Only the garage door opener and the garage ceiling lights

NEC Reference: NEC 2026 — 210.11(C)(4)

Question 4: Per NEC 210.52(A)(1), in dwelling habitable rooms receptacles must be placed so that no point along the floor line of any wall space is more than how far from a receptacle?

  • 12 feet
  • 10 feet
  • 6 feet
  • 4 feet

NEC Reference: NEC 2026 — 210.52(A)(1)

Question 5: Per NEC 210.52(A)(2), what is the smallest wall space in a dwelling room that requires consideration for a receptacle?

  • Any space 6 feet or more
  • Any space 2 feet or more in width
  • Any space 4 feet or more
  • Any space 3 feet or more

NEC Reference: NEC 2026 — 210.52(A)(2)

Question 6: Per NEC 210.52(C)(1), kitchen countertop receptacles must be installed so that no point along the wall line is more than how far from a receptacle?

  • 48 inches
  • 24 inches
  • 36 inches
  • 12 inches

NEC Reference: NEC 2026 — 210.52(C)(1)

Question 7: Per NEC 210.52(C), receptacle outlets serving a kitchen countertop must generally be located not more than how far above the countertop or work surface?

  • 36 inches
  • 24 inches
  • 12 inches
  • 20 inches

NEC Reference: NEC 2026 — 210.52(C)

Question 8: Per NEC 210.52(D), at least one receptacle outlet in a dwelling bathroom must be installed within how far of the outside edge of each basin?

  • 2 feet
  • 6 feet
  • 3 feet
  • 4 feet

NEC Reference: NEC 2026 — 210.52(D)

Question 9: Per NEC 210.52(E)(1), a one-family dwelling needs at least one outdoor receptacle outlet accessible from grade at the front and back, not more than how high above grade?

  • 6½ feet
  • 8 feet
  • 4 feet
  • 5½ feet

NEC Reference: NEC 2026 — 210.52(E)(1)

Question 10: Per NEC 210.52(H), a receptacle outlet is required in dwelling hallways that are at least how long?

  • 12 feet
  • 10 feet
  • 6 feet
  • 20 feet

NEC Reference: NEC 2026 — 210.52(H)

Question 11: Per NEC 210.52(G), in a dwelling garage at least one receptacle outlet must be installed:

  • On the ceiling only
  • Only next to the garage door opener
  • In each vehicle bay, not more than 5½ feet above the floor
  • Only in garages over 400 square feet

NEC Reference: NEC 2026 — 210.52(G)

Question 12: Per NEC 210.63, a 125-volt receptacle for servicing heating, air-conditioning and refrigeration equipment must be located on the same level and within how far of the equipment?

  • 50 feet
  • 6 feet
  • 25 feet
  • 10 feet

NEC Reference: NEC 2026 — 210.63

Question 13: Per NEC 210.12(B), AFCI protection is required for 120-volt, 15- and 20-ampere branch circuits supplying outlets in which dwelling area?

  • Bedrooms
  • Attached garage lighting only
  • Unfinished basements only
  • Outdoor receptacles

NEC Reference: NEC 2026 — 210.12(B)

Question 14: Per NEC 210.12(E), when branch-circuit wiring in a dwelling area that requires AFCI protection is modified, replaced or extended, the circuit must be protected by:

  • A listed AFCI device (combination breaker or outlet branch-circuit AFCI at the first receptacle)
  • Nothing, because existing circuits are exempt from AFCI rules
  • A GFCI receptacle only, installed at the first outlet of the circuit
  • A surge protective device installed at the panelboard

NEC Reference: NEC 2026 — 210.12(E)

Question 15: Per NEC 210.4(B), each multiwire branch circuit must be provided with a means that:

  • Disconnects only the neutral conductor at the panelboard
  • Opens the equipment grounding conductor along with the hots
  • Simultaneously disconnects all ungrounded conductors at the point where the branch circuit originates
  • Allows each ungrounded conductor to be switched off separately

NEC Reference: NEC 2026 — 210.4(B)

Question 16: Per NEC 210.4(D), the ungrounded and grounded conductors of each multiwire branch circuit must be:

  • Grouped together by cable ties or similar means in the panel, unless the grouping is obvious
  • Run in separate raceways so each hot has its own path
  • Different sizes, with the neutral one size larger than the hots
  • Installed only in metal raceway with a full-size neutral

NEC Reference: NEC 2026 — 210.4(D)

Question 17: Per NEC 210.5(C)(1), where a premises has branch circuits from more than one nominal voltage system, each ungrounded conductor must be identified by:

  • A label on the utility meter showing all of the voltages
  • Phase or line and system, with the identification method posted at each branch-circuit panelboard
  • Black insulation only, regardless of the system or phase
  • The circuit breaker number only, written on the panel cover

NEC Reference: NEC 2026 — 210.5(C)(1)

Question 18: Per NEC 210.6(A), in dwelling units the voltage between conductors supplying luminaires and cord-and-plug-connected loads of 1440 VA or less (or less than 1/4 hp) must not exceed:

  • 277 volts
  • 240 volts
  • 120 volts
  • 150 volts

NEC Reference: NEC 2026 — 210.6(A)

Question 19: Per NEC Table 210.21(B)(3), which receptacle ratings may be installed on a 20-ampere multi-outlet branch circuit?

  • 20-ampere receptacles only
  • 15-ampere or 20-ampere receptacles
  • 15-ampere receptacles only
  • 30-ampere receptacles

NEC Reference: NEC 2026 — Table 210.21(B)(3)

Question 20: Per NEC 210.21(B)(1), a single receptacle installed on an individual branch circuit must have an ampere rating:

  • Not less than the rating of the branch circuit
  • Of exactly 15 amperes
  • Not more than 80% of the branch circuit rating
  • Equal to the load only

NEC Reference: NEC 2026 — 210.21(B)(1)

Question 21: Per NEC 210.23(B)(1), on a 20-ampere branch circuit, a single cord-and-plug-connected utilization equipment must not be rated more than:

  • 10 amperes (50%)
  • 12 amperes
  • 16 amperes (80% of the circuit rating)
  • 20 amperes

NEC Reference: NEC 2026 — 210.23(B)(1)

Question 22: Per NEC 210.23(B)(2), on a 20-ampere branch circuit that also supplies lighting outlets, the total rating of equipment fastened in place must not exceed:

  • 10 amperes (50% of the circuit rating)
  • 16 amperes
  • 12 amperes
  • 20 amperes

NEC Reference: NEC 2026 — 210.23(B)(2)

Question 23: Per NEC 210.19(A)(1), branch-circuit conductors supplying 12 amperes of continuous load and 6 amperes of noncontinuous load must have an ampacity of at least:

  • 21 amperes
  • 22.5 amperes
  • 18 amperes
  • 15 amperes

NEC Reference: NEC 2026 — 210.19(A)(1)

Question 24: Per NEC 210.70(A)(2), in a dwelling an interior stairway with six or more risers between floor levels must have a wall switch for the stairway lighting:

  • Only at the bottom of the stairs
  • Anywhere within 25 feet
  • At each floor level and landing level that includes an entryway
  • Only at the top of the stairs

NEC Reference: NEC 2026 — 210.70(A)(2)

Question 25: Per NEC 406.12, tamper-resistant receptacles are required for 125-volt and 250-volt, 15- and 20-ampere receptacles in which location?

  • Only in commercial offices
  • All areas of dwelling units, including garages and outdoors
  • Only in children's bedrooms
  • Only in kitchens

NEC Reference: NEC 2026 — 406.12

Question 26: Per NEC 406.9(B)(1), 15- and 20-ampere, 125- and 250-volt receptacles installed in a wet location must have:

  • Only a flip cover that is weatherproof when the plug is removed
  • A GFCI breaker at the panel instead of any weatherproof cover
  • A metal box with no cover, since the receptacle is listed for outdoor use
  • An enclosure that is weatherproof whether or not the plug is inserted (extra-duty "while-in-use" cover), and be listed weather-resistant

NEC Reference: NEC 2026 — 406.9(B)(1)

Question 27: Per NEC 406.5(E), receptacles in countertops and similar work surfaces must not be installed:

  • In a face-up position, unless listed for countertop or work-surface applications
  • On a 20-ampere circuit, since countertop circuits must be 15 amperes
  • In a kitchen island or peninsula, because receptacles are not required there
  • Within 24 inches of a sink, unless the receptacle is GFCI protected

NEC Reference: NEC 2026 — 406.5(E)

Question 28: Per NEC 406.4(D)(2), where a non-grounding-type receptacle is replaced and no grounding means exists in the box, one permitted option is:

  • A GFCI-type receptacle marked "No Equipment Ground"
  • A grounding-type receptacle with no GFCI and no marking
  • A grounding receptacle with the ground screw jumpered to the neutral
  • A two-prong receptacle bonded to the neutral

NEC Reference: NEC 2026 — 406.4(D)(2)

Question 29: Per NEC 406.4(D)(4), when a receptacle is replaced in an area where AFCI protection is now required, the replacement must be:

  • A listed outlet branch-circuit AFCI receptacle, or a receptacle protected by an upstream AFCI
  • A GFCI receptacle only
  • The same type as the old receptacle with no extra protection
  • A tamper-resistant receptacle only

NEC Reference: NEC 2026 — 406.4(D)(4)

Question 30: Per NEC 210.52(F), a dwelling unit must have at least one receptacle outlet installed:

  • In each laundry area
  • Only where a washer is installed in a garage
  • On the exterior wall at the laundry room
  • In the kitchen only

NEC Reference: NEC 2026 — 210.52(F)

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2026
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)