NEC 2026 Code Questions Practice Test 1

Free NEC 2026 practice test with 30 questions on the rules that apply to every installation: how the Code is laid out (Article 90), key Article 100 definitions, and the Article 110 requirements for working space, terminations, markings and arc-flash labels.

Share this test
Want the real exam format? Take a free full-length exam for your state
TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Before You Start

  • 30 questions, multiple choice
  • 45 minutes, pass mark 70% (21 correct)
  • Have your NEC 2026 open to Articles 90, 100 and 110

Tip: Table 110.26(A)(1) and the termination temperature rules in 110.14(C) show up on almost every journeyman and master exam.

30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC_PRACTICE · NEC 2026
NEC 2026 Code Questions Practice Test 1
Q1 / 30
--:-- ON PACE
Auto-save 0% complete
0%
your score

0
Correct
0
Wrong
0
Skipped
0s
Time
How was this test?
Rate it and add a quick comment. No sign-up.
Tap one to send it now:
Share your score
Share it and get the NEC 2026 Article Quick Reference free, right now.
Unlocked — thanks for sharing! 🎉
Get the NEC 2026 Article Quick Reference
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2026 Code Questions Practice Test 1 — Question List

Question 1: Per NEC 90.5, which words identify a mandatory rule in the Code?

  • "Shall be permitted"
  • "It is recommended"
  • "Shall" or "shall not"
  • "Informational Note"

NEC Reference: NEC 2026 — 90.5

Question 2: Per NEC 90.4, who has the responsibility for interpreting the rules of the Code?

  • The equipment manufacturer
  • The utility company
  • The authority having jurisdiction (AHJ)
  • The electrical contractor

NEC Reference: NEC 2026 — 90.4

Question 3: Per NEC 90.3, Chapters 5, 6 and 7 of the Code:

  • Are informational only and are not enforced unless the AHJ adopts them
  • Replace Chapters 1 through 4 completely for every type of building
  • Apply to special occupancies, equipment or conditions and can supplement or modify Chapters 1 through 7
  • Apply only to installations over 1000 volts and cannot change the general rules

NEC Reference: NEC 2026 — 90.3

Question 4: Per NEC Article 100, a "Continuous Load" is a load where the maximum current is expected to continue for:

  • 30 minutes or more
  • 8 hours or more
  • 1 hour or more
  • 3 hours or more

NEC Reference: NEC 2026 — Article 100

Question 5: Per NEC Article 100, equipment that is "In Sight From" another piece of equipment must be visible and not more than how far away?

  • 10 feet
  • 25 feet
  • 100 feet
  • 50 feet

NEC Reference: NEC 2026 — Article 100

Question 6: Per NEC Article 100, "Approved" means:

  • Acceptable to the authority having jurisdiction
  • Labeled by the manufacturer
  • Listed by a testing laboratory
  • Installed by a licensed electrician

NEC Reference: NEC 2026 — Article 100

Question 7: Per NEC Article 100, "Readily Accessible" means capable of being reached quickly without having to:

  • Use a key, tool or code under any condition, even for authorized persons
  • Open any door, panel cover or hinged enclosure to reach the equipment
  • Climb over obstacles, remove obstacles, or use a portable ladder
  • Walk more than 25 feet from the entrance of the room or building

NEC Reference: NEC 2026 — Article 100

Question 8: Per NEC Article 100, the "Ampacity" of a conductor is:

  • The trip rating of the breaker protecting it
  • Its current at 75°F ambient
  • The short-circuit current it can withstand for 1 second
  • The maximum current it can carry continuously under the conditions of use without exceeding its temperature rating

NEC Reference: NEC 2026 — Article 100

Question 9: Per NEC Article 100, a "Ground Fault" is:

  • An unintended connection between two ungrounded conductors of different phases
  • Any current flowing on the neutral conductor of a multiwire branch circuit
  • An unintentional, electrically conductive connection between an ungrounded conductor and a normally non-current-carrying conductor, metal enclosure, raceway, equipment or the earth
  • The small leakage current that flows through a GFCI when its test button is pressed

NEC Reference: NEC 2026 — Article 100

Question 10: Per NEC Article 100, "Overload" is:

  • Any current above 125% of the breaker rating, no matter how long it lasts
  • A ground fault on a motor that trips the branch-circuit breaker instantly
  • Operation of equipment above its normal full-load rating, or a conductor above its ampacity, that would cause damaging overheating if it lasts long enough
  • A short circuit between two phase conductors that causes very high current

NEC Reference: NEC 2026 — Article 100

Question 11: Per NEC 110.3(B), listed or labeled equipment must be installed and used:

  • In accordance with any instructions included in the listing or labeling
  • Only by the manufacturer's employees
  • In accordance with the AHJ's verbal advice only
  • Only in dry locations

NEC Reference: NEC 2026 — 110.3(B)

Question 12: Per NEC 110.9, equipment intended to interrupt current at fault levels must have an interrupting rating:

  • Equal to the ampacity of the supply conductors
  • Sufficient for the nominal voltage and the current available at the line terminals
  • At least 10,000 amperes in every case
  • Equal to the load current

NEC Reference: NEC 2026 — 110.9

Question 13: Per NEC 110.12, electrical equipment must be installed in a:

  • Fire-rated enclosure
  • Manner approved by the utility
  • Location chosen by the owner
  • Neat and workmanlike manner

NEC Reference: NEC 2026 — 110.12

Question 14: Per NEC 110.14(C)(1)(a), terminations on equipment rated 100 amperes or less (or marked for 14 AWG through 1 AWG conductors) are based on what conductor temperature rating, unless the equipment is marked otherwise?

  • 75°C
  • 105°C
  • 90°C
  • 60°C

NEC Reference: NEC 2026 — 110.14(C)(1)(a)

Question 15: Per NEC 110.14(C)(1)(b), terminations on equipment rated over 100 amperes (or marked for conductors larger than 1 AWG) are based on:

  • 60°C conductor ampacity
  • 90°C conductor ampacity
  • 75°C conductor ampacity
  • The conductor's insulation rating with no limit

NEC Reference: NEC 2026 — 110.14(C)(1)(b)

Question 16: Per NEC Table 110.26(A)(1), what is the minimum depth of working space in front of a 120/240-volt panelboard (150 volts to ground) for any condition?

  • 3½ feet
  • 3 feet
  • 4 feet
  • 2½ feet

NEC Reference: NEC 2026 — Table 110.26(A)(1)

Question 17: Per NEC Table 110.26(A)(1), a 480Y/277-volt panelboard (277 volts to ground) has exposed live parts on one side and grounded parts on the other (Condition 2). What is the minimum working space depth?

  • 4 feet
  • 3 feet
  • 5 feet
  • 3½ feet

NEC Reference: NEC 2026 — Table 110.26(A)(1)

Question 18: Per NEC 110.26(A)(2), the width of the working space in front of electrical equipment must be at least:

  • 24 inches
  • 30 inches or the width of the equipment, whichever is greater
  • The width of the equipment only
  • 36 inches in all cases

NEC Reference: NEC 2026 — 110.26(A)(2)

Question 19: Per NEC 110.26(A)(3), the minimum height of working space for service equipment, switchboards and panelboards is:

  • 7 feet in all cases, regardless of the equipment height
  • 6½ feet or the height of the equipment, whichever is greater
  • 8 feet, measured from the floor to the top of the enclosure
  • 6 feet, or the height of the equipment if it is shorter

NEC Reference: NEC 2026 — 110.26(A)(3)

Question 20: Per NEC 110.26(C)(2), large equipment rated 1200 amperes or more and over 6 feet wide that contains overcurrent devices or switching devices requires:

  • A sprinkler head above the equipment
  • A fire-rated door on the room
  • Only one entrance at any location
  • One entrance to and egress from the working space at each end

NEC Reference: NEC 2026 — 110.26(C)(2)

Question 21: Per NEC 110.26(C)(3), personnel doors within 25 feet of the working space for equipment rated 800 amperes or more must:

  • Be at least 48 inches wide with a closer that holds them shut
  • Be kept locked at all times so only qualified persons can enter
  • Open in the direction of egress and have listed panic or fire exit hardware
  • Open inward only, so the door does not block the hallway outside

NEC Reference: NEC 2026 — 110.26(C)(3)

Question 22: Per NEC 110.26(D), illumination for working spaces about service equipment, switchboards and panelboards installed indoors must:

  • Be emergency lighting
  • Be provided only if the room has no windows
  • Be provided and not be controlled only by automatic means
  • Be on the same circuit as the panel

NEC Reference: NEC 2026 — 110.26(D)

Question 23: Per NEC 110.26(E), the dedicated equipment space above a panelboard extends from the floor to:

  • The finished (suspended) ceiling in all cases
  • 3 feet above the equipment, or the finished ceiling if it is lower
  • 10 feet above the floor, regardless of the structural ceiling
  • 6 feet above the equipment or to the structural ceiling, whichever is lower

NEC Reference: NEC 2026 — 110.26(E)

Question 24: Per NEC 110.16(A), equipment such as panelboards in other than dwelling units that is likely to require examination or maintenance while energized must be:

  • Installed only outdoors where arc flash hazards are reduced
  • Field or factory marked to warn qualified persons of potential arc-flash hazards
  • Locked at all times so only the utility can open it
  • Painted red so workers know it is energized during maintenance

NEC Reference: NEC 2026 — 110.16(A)

Question 25: Per NEC 110.16(B), service equipment rated 1200 amperes or more must have an arc-flash label that includes the nominal system voltage, available fault current, clearing time of the service overcurrent device, and:

  • The utility account number
  • The building permit number
  • The date the label was applied
  • The electrician's license number

NEC Reference: NEC 2026 — 110.16(B)

Question 26: Per NEC 110.24(A), service equipment in other than dwelling units must be legibly marked in the field with:

  • The name of the owner
  • The maximum available fault current and the date the calculation was done
  • The lowest available fault current
  • The size of the grounding electrode conductor

NEC Reference: NEC 2026 — 110.24(A)

Question 27: Per NEC 110.27(A), live parts of electrical equipment operating at 50 volts or more must be:

  • Painted orange
  • Labeled with the circuit number
  • Guarded against accidental contact
  • Located at least 4 feet above the floor

NEC Reference: NEC 2026 — 110.27(A)

Question 28: Per NEC 110.21(B), field-applied hazard markings (caution, warning and danger signs) must:

  • Be printed in red letters only, without any symbols or signal words
  • Be removable so they can be taken off during maintenance work
  • Warn of the hazard using effective words, colors or symbols, and be permanently affixed, not handwritten
  • Be written by hand in permanent marker so they can be updated easily

NEC Reference: NEC 2026 — 110.21(B)

Question 29: Per NEC 110.15, on a 4-wire delta system where the midpoint of one phase is grounded, the conductor with the higher voltage to ground (high leg) must be identified by:

  • Red insulation only, with no other marking permitted
  • Green tape at every termination and junction point
  • An outer finish that is orange in color, or other effective means
  • White tape at the panel, since it is a grounded phase

NEC Reference: NEC 2026 — 110.15

Question 30: The 2026 NEC moved the branch-circuit, feeder and service load calculation rules from Article 220 into which article?

  • Article 310
  • Article 120
  • Article 230
  • Article 215

NEC Reference: NEC 2026 — Article 120

EXAM CARD NEC_PRACTICE
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2026
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)