NEC CODE NEC 2023

Service Entrance , Branch circuits and feeder conductors-2

Service Entrance , Branch circuit conductors and Feeder conductor theory and practice test -2

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 17 min for 10 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — free, no signup required. Each question links to the relevant NEC article so you can study the code directly.

The National Electrical Code (NFPA 70) is the benchmark standard for safe electrical installation in the US. It is updated every 3 years by the NFPA.

Study the edition adopted by your state. As of 2025, most states use the 2020 or 2023 NEC. These tests are written to the 2023 edition.

The most tested articles are 100 (Definitions), 200–250 (Wiring & Grounding), 300–314 (Wiring Methods), 400–411 (Conductors), 430 (Motors), and 700–701 (Emergency Systems).
10
Questions
17 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC CODE · NEC 2023
Service Entrance , Branch circuits and feeder conductors-2
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

Service Entrance , Branch circuits and feeder conductors-2 — Question List

Question 1: Two transformers each are rated for 480 VA are connected from a 120 volts single  feeder. One utilization equipment rated 80 VA is also fed from the same feeder circuit. Which of the following is the minimum ampere rating of feeder?

  • 9 ampere
  • 10 ampere
  • 12 ampere
  • 7 ampere

NEC Reference: NEC 215.52(B)

Question 2: If the dwelling unit rated lighting load is 4000 VA, which of the following is the total branch circuit load calculated for general illumination?

  • 3350 VA
  • 4000 VA
  • 3200 VA
  • 3600 VA

NEC Reference: NEC 220.42

Question 3: What is the branch circuit load calculated for show window which has horizontal size of 10 feet?

  • 2000 V-A
  • 1800 V-A
  • 1600 V-A
  • 2200 V-A

NEC Reference: NEC 220.43(A)

Question 4: How many minimum number of 15-amp No.14 branch circuits are required to provide lighting load for a 2000 sq.ft dwelling unit operated at 120 volts?

  • 3
  • 4
  • 5
  • 6

Question 5: A retail shop consists of 20 15 amp duplex receptacles. which of the calculated load of duplex receptacles in retail shop?

  • 300 volt-ampere
  • 3600 volt-ampere
  • 1800 volt-ampere
  • 36000 volt-amperes.

NEC Reference: NEC 220.14(I)

Question 6: How many maximum number of receptacles are permitted on  a 20 ampere breaker supplied by 120 volts power source in a shopping complex?

  • 13
  • 10
  • 18
  • 11

NEC Reference: NEC 220.14(I)

Question 7: If a single piece of equipment consists of five receptacles on it, what is the total calculated load?

  • 450 Volt-Ampere.
  • 900 Volt-Ampere
  • 600 Volt-ampere
  • 800 Volt-Ampere.

NEC Reference: NEC 220.14(I)

Question 8: How many number of 15 ampere 2 wire branch circuits are required for general lighting load in a 120/240 volts 1200 sq.ft dwelling unit?

  • 1
  • 2
  • 3
  • 4

NEC Reference: NEC 220.12

Question 9: What is the minimum laundry circuit load that shall be considered for each 2-wire laundry branch circuit in dwelling unit?

  • 1500 Volt-Amperes
  • 1200 Volt-Amperes
  • 1000 Volt-Amperes
  • 800 Volt-Amperes

NEC Reference: NEC 220.52(B)

Question 10: The maximum unbalanced load of a service or feeder is the maximum net calculated load between hot and neutral conductor.

  • True
  • False
EXAM CARD NEC CODE
Questions10
Time limit17 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate

Timer starts immediately. Progress is auto-saved.