NEC 2026 Journeyman Practice Test 7

Free Online Journeyman Electrician Practice Test — NEC 2026 Edition 7This free 25-question practice test covers raceways, boxes and cables: conduit fill with Chapter 9 and Annex C, box fill calculations, support spacing for EMT, RMC, PVC, NM and MC, burial depths and protection of cables.

Share this test
Want the real exam format? Take a free full-length exam for your state
TOPICS COVERED
journeyman electrician

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 38 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account required. All questions include detailed explanations and NEC references.

Most state Journeyman exams have 80–100 questions covering NEC code, wiring methods, branch circuits, motor controls, and load calculations.

Most states require a 70–75% passing score. This practice test uses the same 70% pass threshold so you know where you stand.

Questions are written to the 2026 NEC. Check your state licensing board to confirm which edition your state has adopted.

Before You Start

  • 25 questions, multiple choice
  • 37½ minutes, pass mark 70%
  • Have Chapter 9 Tables 1, 4 and 5, Annex C and Table 314.16(B) open
25
Questions
38 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

JOURNEYMAN · NEC 2026
NEC 2026 Journeyman Practice Test 7
Q1 / 25
--:-- ON PACE
Auto-save 0% complete
0%
your score

0
Correct
0
Wrong
0
Skipped
0s
Time
How was this test?
Rate it and add a quick comment. No sign-up.
Tap one to send it now:
Share your score
Share it and get the Journeyman Electrician Cheat Sheet — NEC 2026 free, right now.
Unlocked — thanks for sharing! 🎉
Get the Journeyman Electrician Cheat Sheet — NEC 2026
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2026 Journeyman Practice Test 7 — Question List

Question 1: Per NEC Annex C, Table C.1, what is the maximum number of 12 AWG THHN conductors permitted in 1/2-inch EMT?

  • 7
  • 16
  • 12
  • 9

NEC Reference: NEC 2026 — Annex C, Table C.1

Question 2: Per NEC Annex C, Table C.1, what is the maximum number of 10 AWG THHN conductors permitted in 3/4-inch EMT?

  • 10
  • 6
  • 16
  • 12

NEC Reference: NEC 2026 — Annex C, Table C.1

Question 3: Using Chapter 9, Table 4, the 40% fill area of 3/4-inch EMT is 0.213 in². Each 8 AWG THHN is 0.0366 in². How many fit?

  • 6
  • 7
  • 5
  • 4

NEC Reference: NEC 2026 — Chapter 9, Tables 4 and 5, Note 7

Question 4: Two conductors are installed in a conduit. Per Chapter 9, Table 1, the maximum fill is:

  • 25%
  • 31%
  • 40%
  • 53%

NEC Reference: NEC 2026 — Chapter 9, Table 1

Question 5: Per Chapter 9, Note 3, equipment grounding or bonding conductors in a raceway:

  • Must be included when calculating conduit fill
  • Are not counted in conduit fill
  • Count as half their area
  • Count only if insulated

NEC Reference: NEC 2026 — Chapter 9, Table 1, Note 3

Question 6: A 4 in × 2⅛ in square box is marked 30.3 cubic inches. How many 12 AWG conductors may it contain if there are no devices, clamps or grounds?

  • 15
  • 10
  • 12
  • 13

NEC Reference: NEC 2026 — Table 314.16(A) and 314.16(B)

Question 7: A device box holds a single-pole switch, two 14/2 NM cables with ground (4 insulated conductors and 2 grounds), and no internal clamps. What volume is required?

  • 14.00 cubic inches
  • 18.00 cubic inches
  • 12.00 cubic inches
  • 16.00 cubic inches

NEC Reference: NEC 2026 — 314.16(B)

Question 8: Per NEC 314.16(B)(4), a device yoke counts as two volume allowances based on:

  • The box size
  • The smallest conductor in the box
  • The number of terminals on the device
  • The largest conductor connected to the device

NEC Reference: NEC 2026 — 314.16(B)(4)

Question 9: Per NEC 314.16(B)(3), a luminaire stud or hickey inside a box counts as:

  • One volume allowance for each type of fitting, based on the largest conductor in the box
  • One volume allowance for every fitting in the box, based on 14 AWG
  • Two volume allowances for each fitting, based on the smallest conductor
  • Nothing, because support fittings are part of the box

NEC Reference: NEC 2026 — 314.16(B)(3)

Question 10: Per NEC 314.17, NM cable entering a nonmetallic box must have the sheath extend into the box at least:

  • 1/2 inch
  • 1 inch
  • 6 inches
  • 1/4 inch

NEC Reference: NEC 2026 — 314.17

Question 11: Per NEC 314.17, a single-gang nonmetallic box without cable clamps may be used where the NM cable is secured within how far of the box?

  • 18 inches
  • 6 inches
  • 8 inches
  • 12 inches

NEC Reference: NEC 2026 — 314.17

Question 12: Per NEC 314.23(D), boxes in a suspended (lay-in) ceiling may be supported by:

  • The raceway only, in every case and with no other support
  • A flexible cord tied to the structure above
  • The ceiling tiles, if the box is lightweight
  • Framing members or support wires that are identified and secured at both ends

NEC Reference: NEC 2026 — 314.23(D)

Question 13: Per Table 344.30(B)(2), straight runs of 2-inch rigid metal conduit made up with threaded couplings may be supported at intervals of:

  • 16 feet
  • 12 feet
  • 10 feet
  • 20 feet

NEC Reference: NEC 2026 — Table 344.30(B)(2)

Question 14: Per NEC 348.30(A), flexible metal conduit (FMC) must be secured within 12 inches of each box and at intervals not exceeding:

  • 3 feet
  • 10 feet
  • 6 feet
  • 4½ feet

NEC Reference: NEC 2026 — 348.30(A)

Question 15: Per NEC 350.30(A) Exception, LFMC may be unsupported at terminals where flexibility is needed for lengths not exceeding how long for trade sizes 1/2 through 1¼?

  • 12 inches
  • 3 feet
  • 4½ feet
  • 6 feet

NEC Reference: NEC 2026 — 350.30(A)

Question 16: Per NEC 334.15(C), NM cable run across the lower edges of basement joists must be at least what size, or be run through bored holes or on running boards?

  • Two 12 AWG conductors
  • Two 6 AWG or three 8 AWG conductors
  • Any size
  • Two 10 AWG conductors

NEC Reference: NEC 2026 — 334.15(C)

Question 17: Per NEC 334.24, the minimum bending radius of Type NM cable is how many times the diameter of the cable?

  • 10 times
  • 5 times
  • 3 times
  • 8 times

NEC Reference: NEC 2026 — 334.24

Question 18: Per NEC 334.10, Type NM cable is permitted in multifamily dwellings of which construction types?

  • Type II only
  • Any type including high-rise Type I
  • Type I only
  • Types III, IV and V, except where prohibited

NEC Reference: NEC 2026 — 334.10

Question 19: Per NEC 334.12, Type NM cable is NOT permitted:

  • In attics of one-family dwellings
  • Embedded in poured cement, concrete or aggregate
  • In crawl spaces
  • In wood-frame walls

NEC Reference: NEC 2026 — 334.12

Question 20: Per NEC 300.4(D), cables run parallel to framing members (studs, joists) must be kept at least how far from the nearest edge of the framing member?

  • 2 inches
  • 3/4 inch
  • 1¼ inches
  • 1 inch

NEC Reference: NEC 2026 — 300.4(D)

Question 21: Per NEC 300.4(A)(2), where notches in wood framing are allowed and a cable is laid in the notch, the cable must be protected by:

  • A steel plate at least 1/16 inch thick covering the cable
  • Nothing, notches are always safe
  • Duct tape
  • Nail guards made of plastic

NEC Reference: NEC 2026 — 300.4(A)(2)

Question 22: Per NEC Table 300.5, UF cable under a one-family dwelling driveway (used only for dwelling purposes) must have a cover of at least:

  • 6 inches
  • 12 inches
  • 24 inches
  • 18 inches

NEC Reference: NEC 2026 — Table 300.5

Question 23: Per NEC Table 300.5, landscape lighting circuits limited to not more than 30 volts and installed with Type UF or identified cable may be buried at a minimum depth of:

  • 24 inches
  • 6 inches
  • 18 inches
  • 12 inches

NEC Reference: NEC 2026 — Table 300.5

Question 24: Per NEC 300.5(J), where direct-buried conductors, raceways or cables are subject to movement by settlement or frost, they must be:

  • Encased in concrete for the full length of the run
  • Arranged to prevent damage, such as with S loops in cables or listed expansion fittings in raceways
  • Run only overhead, since burial is not allowed in frost areas
  • Buried at least 6 feet deep so frost cannot reach them

NEC Reference: NEC 2026 — 300.5(J)

Question 25: Per NEC 358.12, EMT is NOT permitted to be used:

  • In dry locations
  • Exposed in a warehouse
  • Where subject to severe physical damage
  • Concealed in walls

NEC Reference: NEC 2026 — 358.12

Key NEC References for This Test

ArticleWhat It Covers
Art. 100Definitions — know: feeder, branch circuit, OCPD, dwelling unit
Art. 210Branch Circuits — GFCI/AFCI locations, circuit ratings, outlet spacing (most tested)
Art. 220Load Calculations — dwelling unit standard method
Art. 250Grounding & Bonding — GEC sizing, electrode system, EGC
Art. 310Conductors — ampacity (Table 310.12), insulation, derate rules
Art. 430Motors — conductor 125% FLA, OCPD 250% FLA, overloads, disconnects
Study Tip: Tab Articles 210, 250, and 430 in your NEC before the exam. Know the Table 310.12 ampacity values for 14, 12, 10, 8, 6, and 4 AWG copper.
EXAM CARD JOURNEYMAN
Questions25
Time limit38 min
Pass score70%
Code editionNEC 2026
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)