JOURNEYMAN NEC 2026

NEC 2026 Journeyman Practice Test 1

Free Online Journeyman Electrician Practice Test — NEC 2026 Edition 1This free 25-question practice test covers branch-circuit fundamentals, receptacle spacing and small-appliance circuits, AFCI protection, and the 2026 NEC's expanded GFCI requirements for garages, basements, and commercial kitchens. Based on the 2026 National Electrical Code.

TOPICS COVERED
journeyman electrician

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 38 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account required. All questions include detailed explanations and NEC references.

Most state Journeyman exams have 80–100 questions covering NEC code, wiring methods, branch circuits, motor controls, and load calculations.

Most states require a 70–75% passing score. This practice test uses the same 70% pass threshold so you know where you stand.

Questions are written to the 2026 NEC. Check your state licensing board to confirm which edition your state has adopted.

How to Use This Practice Test

This NEC 2026 Journeyman Practice Test 1 has 25 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: This is an open-book exam — tab your NEC index and Articles 210, 250, and 430 before you start.

  • Topics covered: Branch circuits, grounding, wiring methods, load calculations, and motors.
  • Passing score: 70–75% (most states). Aim for 80% on practice tests so the real exam feels easy.
  • Questions: 25 multiple-choice, one correct answer each
25
Questions
38 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

JOURNEYMAN · NEC 2026
NEC 2026 Journeyman Practice Test 1
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2026 Journeyman Practice Test 1 — Question List

Question 1: A branch circuit supplies a continuous load of 16 amperes. Per NEC 210.19(A)(1), what is the minimum required ampacity of the branch-circuit conductors, before any correction or adjustment factors?

  • 16 amperes
  • 20 amperes
  • 25 amperes
  • 32 amperes

NEC Reference: NEC 210.19(A)(1)

Question 2: In a dwelling unit habitable room, per NEC 210.52(A)(1), general-use 125-volt, 15- or 20-ampere receptacles must be spaced so that no point along the floor line of any wall space is more than how many feet, measured horizontally, from a receptacle outlet?

  • 4 feet
  • 6 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 210.52(A)(1)

Question 3: Per NEC 210.11(C)(1), a dwelling unit kitchen must be supplied by a minimum of how many 20-ampere small-appliance branch circuits?

  • One
  • Two
  • Three
  • Four

NEC Reference: NEC 210.11(C)(1)

Question 4: Per NEC 210.11(C)(2), the required 20-ampere laundry branch circuit in a dwelling unit is permitted to supply:

  • Only the receptacle outlets in the laundry area
  • Laundry receptacles plus general lighting in the laundry room
  • Laundry receptacles plus a bathroom receptacle
  • Any general-purpose loads in the dwelling

NEC Reference: NEC 210.11(C)(2)

Question 5: On a 20-ampere branch circuit that also supplies fixed lighting outlets, per NEC 210.23(A)(1), the rating of a single cord-and-plug-connected utilization equipment (not fastened in place) must not exceed what percentage of the branch-circuit ampere rating?

  • 50%
  • 75%
  • 80%
  • 100%

NEC Reference: NEC 210.23(A)(1)

Question 6: Per NEC 210.12(A), AFCI protection is required for 120-volt, 15- and 20-ampere branch circuits supplying outlets in a dwelling unit's:

  • Bedrooms, family rooms, and similar living areas
  • Unfinished basements only
  • Attached garages only
  • Outdoor receptacles only

NEC Reference: NEC 210.12(A)

Question 7: Per NEC 240.4(D), the maximum standard overcurrent device rating permitted to protect 10 AWG copper conductors, absent a specific exception elsewhere in the Code, is:

  • 20 amperes
  • 25 amperes
  • 30 amperes
  • 40 amperes

NEC Reference: NEC 240.4(D)

Question 8: Which of the following is a standard ampere rating for fuses and inverse-time circuit breakers listed in NEC 240.6(A)?

  • 55 amperes
  • 65 amperes
  • 70 amperes
  • 85 amperes

NEC Reference: NEC 240.6(A)

Question 9: Per NEC 210.8(A)(1), GFCI protection is required for all 125-volt, 15- and 20-ampere receptacles installed in a dwelling unit's:

  • Bathrooms
  • Bedrooms
  • Living rooms
  • Hallways

NEC Reference: NEC 210.8(A)(1)

Question 10: Per NEC 406.12, tamper-resistant receptacles are required for 125-volt, 15- and 20-ampere general-use receptacles installed in which of the following dwelling unit locations?

  • Essentially all general-use dwelling receptacles covered by 210.52
  • Only receptacles within reach of children under 2 years old
  • Only receptacles in bedrooms
  • Only outdoor receptacles

NEC Reference: NEC 406.12

Question 11: A dwelling unit's attached garage has a 30-ampere, 250-volt receptacle installed for a portable Level 2 EV charger. Per the 2026 NEC, is GFCI protection required for this receptacle?

  • No, only 125V garage receptacles require GFCI
  • Yes, GFCI protection is required
  • Only if the receptacle is within 6 feet of a water source
  • No, EV charging equipment is exempt from 210.8

NEC Reference: NEC 2026 — 210.8(A)(2)

Question 12: A homeowner has a 240-volt, 30-ampere receptacle installed in an unfinished basement to power a stationary table saw. Per the 2026 NEC, this receptacle:

  • Is exempt from GFCI because it is 240V
  • Must be GFCI protected
  • Only needs GFCI if the basement floods regularly
  • Only needs GFCI if it is within 6 feet of a floor drain

NEC Reference: NEC 2026 — 210.8(A)(5)

Question 13: A commercial kitchen has a single-phase, 208-volt receptacle supplying a countertop food processor. Per the 2026 NEC 210.8(B), is GFCI protection required?

  • No, 208V exceeds the 125V GFCI scope
  • Yes, GFCI protection is required
  • Only if the receptacle is within 6 feet of the prep sink
  • Only for receptacles rated over 30A

NEC Reference: NEC 2026 — 210.8(B)(2)

Question 14: Per the 2026 NEC 210.8(A), which of the following dwelling unit locations is on the list of areas requiring GFCI protection for 125V through 250V receptacles?

  • Hallways
  • Crawl spaces at or below grade level
  • Home offices
  • Dining rooms

NEC Reference: NEC 2026 — 210.8(A)

Question 15: A dedicated 120-volt, 20-ampere receptacle serves only a sump pump in a dwelling's unfinished basement. Per the 2026 NEC, may this receptacle omit GFCI protection because it serves a single dedicated appliance?

  • Yes, dedicated-appliance receptacles are exempt
  • No, GFCI protection is still required
  • Yes, if the pump is hard-wired instead of cord-and-plug
  • Yes, if the receptacle is labeled "SUMP PUMP ONLY"

NEC Reference: NEC 2026 — 210.8(A)(5)

Question 16: A 120-volt, 20-ampere receptacle in a dwelling garage is the sole outlet on its branch circuit and serves only a chest freezer. Per the 2026 NEC, is this freezer receptacle permitted to omit GFCI protection?

  • Yes, single-appliance dedicated receptacles are exempt
  • No, GFCI protection is still required
  • Yes, if the receptacle is mounted above 6 feet
  • Yes, because the circuit has no other outlets

NEC Reference: NEC 2026 — 210.8(A)(2)

Question 17: A dwelling has a hard-wired (not plug-connected) exterior post light fed by an outdoor branch circuit. Per the 2026 NEC 210.8(F), is this lighting outlet subject to the GFCI requirement for outdoor outlets?

  • Yes, all outdoor outlets require GFCI
  • No, 210.8(F) applies to receptacle outlets, not hard-wired lighting outlets
  • Only if the fixture is within 6 feet of grade
  • Only if the circuit exceeds 20A

NEC Reference: NEC 2026 — 210.8(F)

Question 18: Per NEC Table 314.16(B), each No. 12 AWG conductor counted in a box fill calculation requires a volume allowance of:

  • 2.00 cubic inches
  • 2.25 cubic inches
  • 2.50 cubic inches
  • 3.00 cubic inches

NEC Reference: NEC Table 314.16(B)

Question 19: Per NEC Article 100, a "Continuous Load" is defined as a load where the maximum current is expected to continue for:

  • 30 minutes or more
  • 1 hour or more
  • 3 hours or more
  • 8 hours or more

NEC Reference: NEC Article 100

Question 20: Per NEC Article 100, "Readily Accessible" means capable of being reached quickly, without requiring the user to:

  • Climb over or remove obstacles or use portable ladders
  • Walk more than 10 feet
  • Enter a locked room using a master key
  • Use a flashlight

NEC Reference: NEC Article 100

Question 21: Per NEC 210.70(A)(1), at least one wall-switch-controlled lighting outlet must be installed in every:

  • Habitable room and bathroom of a dwelling unit
  • Attic and crawl space only
  • Detached accessory building only
  • Garage only, not habitable rooms

NEC Reference: NEC 210.70(A)(1)

Question 22: Per NEC Table 220.12, the general lighting load for a dwelling unit is calculated at a minimum of how many volt-amperes per square foot?

  • 1.5 VA
  • 2 VA
  • 3 VA
  • 5 VA

NEC Reference: NEC Table 220.12

Question 23: Per NEC 406.4(D)(2), where a single GFCI device protects one or more downstream, non-GFCI receptacles on the same circuit, each protected downstream receptacle must be marked with which label?

  • "GFCI Protected"
  • "AFCI Protected"
  • "No Equipment Ground - Test Monthly"
  • No marking is required

NEC Reference: NEC 406.4(D)(2)

Question 24: A dwelling unit has a wet bar sink in the basement recreation room. Per NEC 210.8(A)(7), a 125-volt receptacle located within how many feet of the top inside edge of the sink bowl requires GFCI protection?

  • 3 feet
  • 6 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 210.8(A)(7)

Question 25: A Class A GFCI device intended for personnel protection is designed to trip at a ground-fault current of approximately:

  • 4 to 6 milliamperes
  • 15 milliamperes
  • 30 milliamperes
  • 50 milliamperes

NEC Reference: NEC 210.8 / UL 943

Key NEC References for This Test

ArticleWhat It Covers
Art. 100Definitions — know: feeder, branch circuit, OCPD, dwelling unit
Art. 210Branch Circuits — GFCI/AFCI locations, circuit ratings, outlet spacing (most tested)
Art. 220Load Calculations — dwelling unit standard method
Art. 250Grounding & Bonding — GEC sizing, electrode system, EGC
Art. 310Conductors — ampacity (Table 310.12), insulation, derate rules
Art. 430Motors — conductor 125% FLA, OCPD 250% FLA, overloads, disconnects
Study Tip: Tab Articles 210, 250, and 430 in your NEC before the exam. Know the Table 310.12 ampacity values for 14, 12, 10, 8, 6, and 4 AWG copper.
EXAM CARD JOURNEYMAN
Questions25
Time limit38 min
Pass score70%
Code editionNEC 2026
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)