HVAC NEC 2023

HVAC Controls & Sensors Practice Test 2

Free HVAC Controls & Sensors Practice Test 2. 25 questions covering thermistors, magnetic flow meters, Bourdon tube pressure sensors, ASHRAE humidity limits, thermopiles, self-powered VAV diffusers, capacitive humidity sensors, CO2 NDIR sensors, differential pressure transmitters, RTD wiring configurations, PIR occupancy sensors, velocity/static/total pressure relationships, duct pressure sensor placement, sensor calibration, and CO safety detection.

Share this test
TOPICS COVERED
HVAC Practice tests hvac

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no signup required.

HVAC electrical exams cover electrical theory (Ohm's Law, circuits), transformers, single-phase and three-phase motors, control wiring, safety, and troubleshooting.

Requirements vary by state. HVAC technicians typically need EPA 608 certification and may need a separate electrical license for line voltage work.

Key sensor review: Thermistor (NTC) — resistance decreases as temperature rises, very sensitive but non-linear. RTD (PT100) — resistance increases linearly with temperature; 100Ω at 0°C. Thermocouple — self-powered, millivolt output, best for high temps. Bourdon tube — mechanical pressure sensor, curls/uncurls with pressure changes. Thermopile — multiple thermocouples in series, self-powered, higher output voltage than a single thermocouple.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

HVAC · NEC 2023
HVAC Controls & Sensors Practice Test 2
Q1 / 25
--:-- ON PACE
Auto-save 0% complete
0%
your score

0
Correct
0
Wrong
0
Skipped
0s
Time
How was this test?
One tap, no sign-up.
Share your score
Share it and get the HVAC Electrical Theory Quick Reference free, right now.
Unlocked — thanks for sharing! 🎉
Get the HVAC Electrical Theory Quick Reference
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

HVAC Controls & Sensors Practice Test 2 — Question List

Question 1: Themisters are used to measure which of the following quantity?

  • Temperature
  • Resistance
  • Pressure
  • Humidity

Question 2: Which of the following is the magnetic flow meter output signal?

  • Voltage signal
  • Pneumatic signal
  • Hydraulic signal
  • Pressure signal

Question 3: The amount of water vapor that moisture contains increases rapidly with increase in temperature.

  • True
  • False

Question 4: What is the maximum allowed relative humidity to maintain indoor air quality as per ASHRAE?

  • 65 %
  • 85 %
  • 90 %
  • 70 %

Question 5: A bourdon tube sensor is used to measure ………..

  • Temperature
  • Pressure
  • Flow velocity
  • Humidity

Question 6: Magnetic flow measures the flow rate by ………………………. Caused by the moving fluid when exposed to strong magnetic field?

  • Magnetic induction
  • Electric induction
  • Acceleration of diaphragm
  • Movement of the coil

Question 7: The aim of HVAC control system

  • Lower energy cost
  • Increase flexibility
  • Lower operating cost
  • All the options are correct

Question 8: Which of the following device is self powered control device?

  • Thermopile
  • Thermocouple
  • Thermister
  • Thermostat

Question 9: What may be maximum pressure that self powered VAV diffuser can operate?

  • 60 kpa
  • 20 kpa
  • 50 kpa
  • 90 kpa

Question 10: Which of the following is not a self powered control device?

  • Thermopile
  • VAV diffuser
  • Hot Water Control Valve
  • Pneumatic

Question 11: How does a capacitive polymer humidity sensor measure relative humidity?

  • A capacitive humidity sensor measures humidity by changing the resistance of a wire exposed to moisture in the air
  • A capacitive polymer sensor absorbs water molecules which change the polymer dielectric constant and thus capacitance; electronics convert the capacitance change to an RH output signal (0-10V or 4-20mA)
  • Capacitive sensors cannot measure humidity — they are only used to measure pressure in HVAC systems
  • A capacitive humidity sensor works by measuring the dew point temperature using a chilled mirror

Question 12: What type of CO2 sensor is most commonly used in HVAC demand-controlled ventilation (DCV), and how does it work?

  • Chemical absorption sensors are the standard for CO2 measurement — they change color when CO2 is present
  • NDIR (Non-Dispersive Infrared) sensors are the standard — CO2 absorbs IR at 4.26 µm; less IR at the detector = higher CO2 concentration. Output: 4-20 mA proportional to CO2 ppm
  • Electrochemical CO2 sensors are used in HVAC because they are cheaper than infrared sensors
  • CO2 is measured with thermocouples — heat generated by CO2 combustion indicates concentration

Question 13: How does a differential pressure (DP) sensor measure airflow in a VAV box, and what is the relationship between velocity pressure and airflow?

  • A DP sensor in a VAV box measures the air temperature difference between supply and return to calculate airflow
  • A DP sensor measures velocity pressure (total − static); velocity = 4005 × √VP and CFM = velocity × duct area; the VAV controller modulates the damper to hit the CFM setpoint
  • VAV airflow is measured with a turbine flow meter installed in each branch duct
  • Differential pressure sensors in VAV boxes measure the refrigerant pressure, not airflow

Question 14: Why are 3-wire RTDs preferred over 2-wire RTDs in HVAC applications, and when would you use a 4-wire RTD?

  • 3-wire RTDs are preferred because they require less copper wire and reduce installation cost
  • 3-wire RTDs compensate for lead wire resistance using a third wire to measure and subtract lead resistance; 4-wire RTDs provide the highest accuracy by using separate current and sense wires for complete lead resistance elimination
  • 2-wire RTDs are more accurate than 3-wire RTDs because they have fewer connections that could introduce resistance
  • RTD wiring type does not affect accuracy — the wire length only matters for signal loss in voltage-type sensors

Question 15: A thermistor with a negative temperature coefficient (NTC) will:

  • Produce its own voltage when heated
  • Have higher resistance as temperature rises
  • Keep the same resistance at all temperatures
  • Have lower resistance as temperature rises

Question 16: A common 10k NTC thermistor reads about 10,000 ohms at what temperature?

  • 77°F (25°C)
  • 212°F (100°C)
  • 32°F (0°C)
  • 0°F (-18°C)

Question 17: A 4-20 mA sensor reading 4 mA usually means:

  • The sensor is at the bottom (zero) of its range
  • The sensor wiring is open
  • The sensor is at full scale
  • The sensor is reading 50%

Question 18: A 0-10 V DC damper actuator receiving 5 V should be at about what position?

  • 50% open
  • Fully open
  • 10% open
  • Fully closed

Question 19: An RTD (resistance temperature detector) works because the resistance of its metal element:

  • Changes in a known, repeatable way with temperature
  • Produces a voltage like a thermocouple
  • Depends only on humidity
  • Becomes zero above 100°F

Question 20: A thermocouple produces a signal by:

  • Changing its capacitance with humidity
  • Generating a small voltage where two different metals are joined and heated
  • Changing its resistance with temperature
  • Switching contacts open and closed

Question 21: In a direct digital control (DDC) system, a temperature sensor is wired to which type of controller point?

  • Digital output
  • Analog output
  • Binary output
  • Analog input

Question 22: A fan status current switch wired into a DDC controller is an example of a:

  • Binary output
  • Binary (digital) input
  • Analog input
  • Analog output

Question 23: An enthalpy sensor used for economizer control measures:

  • Both temperature and humidity, so the total heat in the air is known
  • Only the duct static pressure
  • Only the outdoor air temperature
  • Only the CO2 level

Question 24: A duct static pressure sensor in a VAV system is most often used to:

  • Detect refrigerant leaks
  • Measure room humidity
  • Control the reheat coil valve
  • Control the speed of the supply fan (VFD)

Question 25: A mixed-air low-limit thermostat (freezestat) on an air handler is installed to:

  • Speed up the economizer
  • Protect water coils from freezing by shutting down the fan or closing outdoor dampers
  • Raise the supply air temperature setpoint
  • Measure the outdoor humidity

Key NEC References for This Test

ArticleWhat It Covers
Art. 440Air Conditioning Equipment — use nameplate MCA and MOCP, not FLA alone
Art. 430Motors — general motor rules that Art. 440 modifies
Study Tip: Practice reading ladder diagrams. Trace each rung from L1 to the load: contacts open → circuit dead. Contacts closed → current flows. This is how HVAC electrical troubleshooting works.
EXAM CARD HVAC
Questions25
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 Art. 440 & electrical theory