Key NEC References for This Test
| Article | What It Covers |
|---|---|
| Art. 440 | Air Conditioning Equipment — use nameplate MCA and MOCP, not FLA alone |
| Art. 430 | Motors — general motor rules that Art. 440 modifies |
Free HVAC Heat Pump Practice Test 2. 25 questions covering heat pump installation costs, air handler CFM calculations, low-voltage compressor effects, heating and cooling mode heat flow, indoor coil evaporator function, outdoor heat sink, frost efficiency reduction, defrost cycle timing, auxiliary heat in defrost, defrost thermostat location, dual fuel hybrid systems, outdoor unit clearances, condensate drain requirements, refrigerant overcharge and undercharge symptoms, HSPF heating efficiency rating, ECM blower motor advantages, MERV filter ratings, thermostat wiring terminals, lock-out tag-out safety procedures, capacitor functions, and heat pump noise troubleshooting.
Key concepts for this test: The CFM formula for air systems is CFM = BTU ÷ (1.08 × ΔT). A low supply voltage (below 90% of rated) causes compressor current to increase and can lead to overheating. During the defrost cycle, auxiliary heat strips energize to keep the indoor air warm while the heat pump temporarily switches to cooling to melt outdoor coil frost. The defrost thermostat is located at the bottom of the outdoor coil where ice first forms.
Timer starts immediately. Progress is auto-saved.
| Article | What It Covers |
|---|---|
| Art. 440 | Air Conditioning Equipment — use nameplate MCA and MOCP, not FLA alone |
| Art. 430 | Motors — general motor rules that Art. 440 modifies |
Timer starts immediately. Progress is auto-saved.
16 unanswered · click to confirm
Key formulas · NEC articles · Ampacity tables · Exam tips
Drop your email and we'll send you the link instantly — plus notify you when new practice tests drop. No spam. Unsubscribe any time.
Already subscribed? Open cheat sheet →