Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

How to Use This Practice Test

This EPA 608 Core Exam Practice Test 9 has 15 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: The EPA 608 exam is NOT open book — memorize refrigerant ODP/GWP values and recovery rules before the exam.

  • Topics covered: Refrigerant regulations, recovery procedures, leak detection, and refrigerant properties.
  • Passing score: 70% required on each section. Universal certification requires passing all four sections.
  • Questions: 15 multiple-choice, one correct answer each
15
Questions
23 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608 · NEC 2023
EPA 608 Core Exam Practice Test 9
Q1 / 15
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 9 — Question List

Question 1: What will happen if the system is pressurized with oxygen or compressed air?

  • When mixed with oil or refrigerant they can cause an explosion
  • When mixed with refrigerant, the pressure in the system will increase unusually
  • The compressed air can damage the suction line filter placed before the compressor
  • The oxygen mixture with oil will damage compressor

Question 2: CFC’s are lighter than air.

  • True
  • False

Question 3: One chlorine atom can break apart more than …………………. Ozone molecules

  • 1,00,000
  • 10,00,000
  • 10,000
  • 1000

Question 4: The compressor is located in …………… part of the refrigeration circuit?

  • Vapour
  • Liquid

Question 5: The liquid boiling point in the closed loop system can be controlled by changing …………… above it.

  • Vapour temperature
  • Vapour pressure
  • Vapour volume
  • Vapour flow

Question 6: A high pressure gauge in manifold gauge set is usually ………… in color.

  • red
  • blue
  • yellow
  • white

Question 7: When the air present inside the refrigeration circuit …

  • The pressure at high pressure side reads unusually high
  • The pressure at high pressure side reads unusually low
  • The pressure at Low pressure side reads unusually high
  • The pressure at low pressure side reads unusually low

Question 8: The process which removes the moisture and oil from and the refrigerant and chemically tests the refrigerant is

  • Recycling
  • Reclaiming
  • Recovery
  • Disposal

Question 9: Refrigerant recovery equipment manufactured after ……………… must be certified and labeled by the EPA approved equipment testing agency to meet EPA standards

  • November 15, 1993
  • July 2, 1987
  • November 14, 1994
  • June 16, 1989

Question 10: HFC refrigerant leak cannot be detected by following detector?

  • Electronic detector
  • Halide leak detector
  • Ultrasonic leak detector
  • Fluorescent Dye Leak Detector

Question 11: Which of the following refrigerant is drop-in substitute of R-12?

  • R-22
  • R-134a
  • R-234
  • none

Question 12: The speed of the evacuation depends on

  • Size of the system
  • Ambient temperature
  • Quality of the moisture
  • All

Question 13: For maximum security what should be done to the cylinder before disposal?

  • Recovery the remaining refrigerant
  • Heat with the open flame to check for any refrigerant leaks
  • Cylinder should be punctured

Question 14: The suction line up to the compressor is iced up in air conditioning unit, what would be the indication?

  • A clean evaporator coil
  • An improper function of expansion valve
  • Under charge of refrigerant
  • Over charge of refrigerant

Question 15: The refrigerant recovered from refrigeration system …………….

  • without any restriction it can be returned to same or other system owned by same person
  • can be returned to another system if it is charged with same refrigerant
  • can be sold to another costumer
  • can be said it is reclaimed if the oil is filtered
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.