EPA 608 NEC 2023

EPA 608 Core Exam Practice Test 8

Free Online EPA 608 Core Exam Practice Test 8This free 25-question practice test covers core EPA 608 topics for refrigerant certification. Topics include atmospheric layers, blended refrigerant fractionation, CFC refrigerant identification, technician certification rules, manifold gauge colors, heat flow, refrigeration cycle pressure components, AHRI 700 purity standard, Section 609 MVAC, system-dependent recovery, electronic leak detectors, recovery speed factors, evacuation hose sizing, recovery cylinder fill limits, and nitrogen pressure regulators. New questions cover azeotropic vs zeotropic blends, subcooling, superheat, EPA 608 exam structure, flash gas, receiver tanks, temperature glide, refrigerant scales, and compressor oil types.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Key facts for this test: The troposphere is the layer we live in; the ozone layer is in the STRATOSPHERE. Blended refrigerants leak at uneven rates (fractionation) due to different vapor pressures. R-12 is a CFC. Yellow hose = center (utility) port. Heat flows from HOT to COLD always. Condenser and evaporator do NOT change pressure — only the compressor and expansion valve do. AHRI 700 = purity standard for reclaimed refrigerant. Electronic detectors are preferred for small leaks. Recovery cylinders must NOT exceed 80% of water capacity. Always use a pressure regulator with nitrogen.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Core Exam Practice Test 8
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 8 — Question List

Question 1: Which of the following layer of earth atmosphere that surrounds us?

  • Troposphere
  • Stratosphere
  • Hemisphere
  • None

Question 2: A blended refrigerant charged in a system may leak ___________.

  • Faster than other systems
  • Slower than other systems
  • At uneven rates due to different pressures
  • At the coupling points only

Question 3: Which refrigerant is a CFC?

  • R-12
  • R-500
  • R-124
  • R-410 A

Question 4: If a technician fails to demonstrate proper recovery and reclaiming procedures when the EPA requires it, ___________.

  • The technician certificate will be revoked
  • The recovery equipment and recovery cylinders will be seized
  • The cylinders recently purchased and still in his possession will be seized
  • The technician will be advised to attend refrigeration training camp

Question 5: Which of the following is usually central port of the manifold gauge?

  • Yellow hose
  • Red hose
  • Blue hose
  • White hose

Question 6: Heat flows from a material at ___________ to a material at ___________.

  • higher temperature, lower temperature
  • lower temperature, higher temperature
  • higher pressure , lower pressure
  • lower pressure to higher pressure

Question 7: Which of the following refrigeration circuit components does not modify the pressure of the refrigerant?

  • Condenser and evaporator
  • Compressor and evaporator
  • Expansion valve and compressor
  • Condenser and compressor

Question 8: What is the purity standard that the reclaimed refrigerant should meet to be resold or reused in any other system?

  • ARI 700
  • ARI 741
  • EPA 608
  • EPA 609

Question 9: Only ___________ technicians can purchase CFC-12 refrigerant in small containers for automotive A/C service.

  • EPA Section 609 certified
  • EPA Section 608 certified
  • EPA section 608 type 1 certified
  • EPA section 608 type 2 certified

Question 10: A recovery device that uses the appliance's own compressor to assist in refrigerant recovery is called a ___________.

  • Self-contained recovery machine
  • System dependent recovery machine

Question 11: What is the preferred detector for detecting the small refrigerant leaks?

  • Electronic detector
  • Halide leak detector
  • Ultrasonic leak detector
  • Fluorescent Dye Leak Detector

Question 12: The speed of refrigerant recovery depends on ___________.

  • Size of the refrigeration circuit only
  • Ambient temperature only
  • Type of refrigerant only
  • Size of circuit and ambient temperature

Question 13: What should be followed with a gauge set hose to be used in evacuating a system?

  • Hose length should be smaller
  • Hose diameter should be equal to vacuum pump inlet or larger
  • Hoses should be fitted with low loss fittings
  • Hose diameter should be less than vacuum pump inlet

Question 14: EPA regulations require that refrigerant recovery cylinders must NOT be filled to more than ___________ of their total water capacity.

  • 80%
  • 85%
  • 90%
  • 95%

Question 15: Pressurized nitrogen must always be charged into a refrigerant system through a ___________.

  • Metering device to monitor the pressure
  • Pressure regulator to control the pressure
  • On/Off valve to cut-off when required pressure is reached
  • Compressor to increase the nitrogen pressure

Question 16: An azeotropic refrigerant blend (such as R-500 or R-502) behaves differently from a zeotropic blend because it ___________.

  • Requires liquid charging to prevent fractionation
  • Behaves like a single refrigerant with no temperature glide and no fractionation
  • Has a wider temperature glide than zeotropic blends
  • Must always be recovered separately from other refrigerants

Question 17: In a refrigeration system, "subcooling" refers to ___________.

  • The temperature drop across the expansion valve
  • Cooling the liquid refrigerant below its saturation temperature before the expansion valve
  • Adding extra refrigerant to a system to reduce high-side pressure
  • The difference between suction and discharge temperatures

Question 18: In a refrigeration system, "superheat" refers to ___________.

  • Overheating the compressor motor windings
  • The degrees the suction vapor has been heated above its saturation temperature
  • The temperature increase across the condenser
  • Adding extra heat to the refrigerant before it enters the evaporator

Question 19: The EPA 608 technician certification examination is divided into how many sections, and what are they?

  • 2 sections — Core and Practical
  • 3 sections — Type I, Type II, and Type III
  • 4 sections — Core, Type I, Type II, and Type III
  • 5 sections — Core, MVAC, Type I, Type II, and Type III

Question 20: "Flash gas" in a refrigeration system is formed at the ___________ and serves what purpose?

  • Compressor — hot discharge gas that enters the condenser
  • Condenser — vapor that does not condense to liquid
  • Expansion valve — a portion vaporizes to instantly cool the remaining liquid
  • Evaporator — gas that forms when refrigerant absorbs too much heat

Question 21: What is the purpose of a "receiver" (liquid receiver) in a refrigeration system?

  • To recover refrigerant from the system during service
  • To store extra liquid refrigerant and ensure a steady, bubble-free supply to the expansion valve
  • To separate oil from refrigerant before it returns to the compressor
  • To cool the refrigerant between the compressor and condenser

Question 22: "Temperature glide" in a zeotropic refrigerant blend means that ___________.

  • The refrigerant temperature rises as it flows through the system
  • The blend evaporates and condenses over a range of temperatures at constant pressure
  • The refrigerant glides from the liquid line to the suction line without changing temperature
  • Different refrigerants in the blend reach the compressor at different times

Question 23: When charging refrigerant into a system by weight, what instrument is required?

  • A manifold gauge set to monitor pressure while charging
  • An electronic digital refrigerant charging scale
  • A thermometer to verify the system is at the correct temperature
  • A flow meter to measure refrigerant volume

Question 24: Which type of compressor oil is required in systems using HFC refrigerants such as R-410A or R-134a?

  • Mineral oil
  • Polyolester (POE) oil
  • Motor oil (SAE 30)
  • Polyalkylene Glycol (PAG) oil

Question 25: Under EPA Section 608, who is allowed to purchase refrigerant in containers larger than 2 pounds?

  • Anyone who is at least 18 years old
  • Only EPA Section 608 certified technicians
  • Certified technicians AND licensed HVAC contractors
  • Only Universal-certified technicians (all four sections passed)
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit45 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)