EPA 608 Core Exam Practice Test 10

Free Online Practice Tests: EPA 608 Core Exam Practice Test-10

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 23 min for 15 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

How to Use This Practice Test

This EPA 608 Core Exam Practice Test 10 has 15 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: The EPA 608 exam is NOT open book — memorize refrigerant ODP/GWP values and recovery rules before the exam.

  • Topics covered: Refrigerant regulations, recovery procedures, leak detection, and refrigerant properties.
  • Passing score: 70% required on each section. Universal certification requires passing all four sections.
  • Questions: 15 multiple-choice, one correct answer each
15
Questions
23 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608 · NEC 2023
EPA 608 Core Exam Practice Test 10
Q1 / 15
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 10 — Question List

Question 1: To service or refill the existing the CFC refrigeration systems in USA, the CFC should come from ……………… after 1995 onwards

  • Recovery and recycling
  • Solvent conversion
  • From approved chemical laboratories
  • European chemical manufactures

Question 2: Which atoms can destroy more ozone molecules when they react with them?

  • Chlorine
  • Bromine
  • Nitrogen
  • Carbon

Question 3: …………..  is responsible for specific flow rates and pressure in the refrigeration circuit.

  • Compressor
  • Condenser
  • Evaporator
  • Expansion valve

Question 4: The low pressure gauge reads the system pressures above atmospheric pressure in ………….

  • Pounds per Square Inch (PSIG)
  • Inches of mercury (in.Hg)
  • Pounds per Square Inch absolute (PSIA)
  • Kilo Pascal (Kpa)

Question 5: What should be the typical pressure of disposable recovery cylinder before disposing it?

  • Zero
  • Low pressure below 10 psig
  • Below 20 psig
  • Below 14.2 psig

Question 6: HCFC-22 is a high pressure refrigerant.

  • True
  • False

Question 7: Electronic leak detector must have a sensitivity of …………………

  • 5 g per year
  • 10 g per year
  • 15 g per year
  • 20 g per year

Question 8: Which of the following refrigerant is leading candidate for CFC-12 retrofit?

  • R-22
  • R-134a
  • R-234
  • R-500

Question 9: What should be placed in the system to prevent any debris that may damage the compressor?

  • A suction line filter dryer
  • An accumulator
  • A regulatory valve
  • Moisture cleaner

Question 10: What does happen to system if moisture is still left in an operating system?

  • Moisture mixes with oil and refrigerant and produces the acids
  • Increases the pressure in condenser and affects heat transfer
  • Operating compressor with moisture may damage the compressor motor windings
  • Damages the evaporator coil

Question 11: With what the technician can conclude that the system is fully dehydrated?

  • When the low pressure gauge reads deep vacuum
  • When the pressure reading does not rise even after the vacuum pump is turned off
  • When system pressure reading is normal in low pressure gauge
  • When the shutoff valves are closed due to low deep vacuum during evacuation

Question 12: In case of recovery cylinders are not available, the disposable cylinders can be used as recovery cylinders after proper testing and approval

  • True
  • False

Question 13: When leak checking the refrigeration system never pressurize the system with ………….

  • Nitrogen
  • Oxygen
  • Hydrogen
  • Helium

Question 14: Which of the following refrigerants has lower ozone depletion potential (ODP)?

  • R -11
  • R-22
  • R-134a
  • R-12

Question 15: Which of the following refrigerant blend can also be charged as vapour?

  • Alkylbenzene
  • Zeotropic
  • Azeotropic
  • Near-azeotropic
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions15
Time limit23 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)