EPA 608 Core Exam Practice Test 10

Free EPA 608 Core Exam Practice Test 10. 25 questions covering CFC service sources after 1995, atoms that destroy ozone, compressor function, manifold gauge pressure units, disposable cylinder disposal, R-22 pressure classification, electronic leak detector sensitivity, CFC-12 retrofit refrigerant, suction line filter dryers, moisture in refrigerant, dehydration verification, disposable cylinder rules, oxygen prohibition, refrigerant ODP comparison, azeotropic blend charging, R-410A pressure, POE oil, acid testing, filter dryers, triple evacuation, micron gauges, cylinder hydrostatic testing, R-410A retrofit, open flames, and technician certification.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Key facts for this test: R-22 (HCFC-22) IS a high-pressure refrigerant — it saturates at about 121 psig at 70°F and is used in Type II equipment. Among common refrigerants, R-134a has the lowest ODP (zero) because it contains no chlorine. Bromine atoms actually destroy MORE ozone per atom than chlorine atoms. Electronic leak detectors must have a sensitivity of at least 5 grams per year. R-134a is the leading retrofit candidate for R-12 because it is non-toxic, non-flammable, has zero ODP, and has similar operating pressures.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Core Exam Practice Test 10
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 10 — Question List

Question 1: To service or refill the existing the CFC refrigeration systems in USA, the CFC should come from ……………… after 1995 onwards

  • Recovery and recycling
  • Solvent conversion
  • From approved chemical laboratories
  • European chemical manufactures

Question 2: Which atoms can destroy more ozone molecules when they react with them?

  • Chlorine
  • Bromine
  • Nitrogen
  • Carbon

Question 3: …………..  is responsible for specific flow rates and pressure in the refrigeration circuit.

  • Compressor
  • Condenser
  • Evaporator
  • Expansion valve

Question 4: The low pressure gauge reads the system pressures above atmospheric pressure in ………….

  • Pounds per Square Inch (PSIG)
  • Inches of mercury (in.Hg)
  • Pounds per Square Inch absolute (PSIA)
  • Kilo Pascal (Kpa)

Question 5: What should be the typical pressure of disposable recovery cylinder before disposing it?

  • Zero
  • Low pressure below 10 psig
  • Below 20 psig
  • Below 14.2 psig

Question 6: HCFC-22 is a high pressure refrigerant.

  • True
  • False

Question 7: Electronic leak detector must have a sensitivity of …………………

  • 5 g per year
  • 10 g per year
  • 15 g per year
  • 20 g per year

Question 8: Which of the following refrigerant is leading candidate for CFC-12 retrofit?

  • R-22
  • R-134a
  • R-234
  • R-500

Question 9: What should be placed in the system to prevent any debris that may damage the compressor?

  • A suction line filter dryer
  • An accumulator
  • A regulatory valve
  • Moisture cleaner

Question 10: What does happen to system if moisture is still left in an operating system?

  • Moisture mixes with oil and refrigerant and produces the acids
  • Increases the pressure in condenser and affects heat transfer
  • Operating compressor with moisture may damage the compressor motor windings
  • Damages the evaporator coil

Question 11: With what the technician can conclude that the system is fully dehydrated?

  • When the low pressure gauge reads deep vacuum
  • When the pressure reading does not rise even after the vacuum pump is turned off
  • When system pressure reading is normal in low pressure gauge
  • When the shutoff valves are closed due to low deep vacuum during evacuation

Question 12: In case of recovery cylinders are not available, the disposable cylinders can be used as recovery cylinders after proper testing and approval

  • True
  • False

Question 13: When leak checking the refrigeration system never pressurize the system with ………….

  • Nitrogen
  • Oxygen
  • Hydrogen
  • Helium

Question 14: Which of the following refrigerants has the lowest ozone depletion potential (ODP)?

  • R -11
  • R-22
  • R-134a
  • R-12

Question 15: Which of the following refrigerant blend can also be charged as vapour?

  • Alkylbenzene
  • Zeotropic
  • Azeotropic
  • Near-azeotropic

Question 16: R-410A operates at approximately how much higher pressure than R-22?

  • About the same pressure as R-22
  • About 60–70% higher pressure than R-22
  • About 10% higher pressure than R-22
  • About 200% higher pressure than R-22

Question 17: Which type of compressor oil must be used in systems that use HFC refrigerants such as R-410A or R-134a?

  • Mineral oil
  • Polyolester (POE) oil
  • Alkylbenzene (AB) oil
  • PAG oil

Question 18: After a compressor burnout in a refrigeration system, what should the technician do to check for acid contamination?

  • Replace the compressor immediately without testing
  • Take an oil sample and test it with an acid test kit
  • Add more refrigerant to dilute any acid
  • Purge the system with oxygen to remove acid

Question 19: What is the main job of a filter dryer (liquid line drier) in a refrigeration system?

  • To separate oil from refrigerant
  • To remove moisture and solid contaminants from the refrigerant
  • To cool the refrigerant between the compressor and condenser
  • To store extra refrigerant when the system load is low

Question 20: The triple evacuation method is used to ___________.

  • Recover refrigerant three times to ensure all is removed
  • Remove moisture more effectively by breaking vacuum with dry nitrogen between pulls
  • Test a system three times for leaks before charging
  • Charge a system in three stages to prevent frost

Question 21: What instrument is used to measure how deep a vacuum has been pulled in a refrigeration system during evacuation?

  • A compound manifold gauge set
  • A micron gauge (electronic vacuum gauge)
  • A digital thermometer
  • A clamp-on ammeter

Question 22: How often must DOT-approved refrigerant recovery cylinders be hydrostatic tested?

  • Every year
  • Every 5 years
  • Every 10 years
  • No testing required

Question 23: Can R-410A be used as a direct drop-in replacement for R-22 in an existing R-22 air conditioning system?

  • Yes — just replace the refrigerant and the system will work fine
  • No — R-410A requires different equipment, oil, and operates at much higher pressure
  • Yes — but only in systems made after 1995
  • Yes — if a new expansion valve is installed first

Question 24: Why should you never use an open flame or lit halide torch detector near HFC refrigerants?

  • HFCs are highly flammable and will ignite
  • Burning HFCs produces toxic gases including hydrogen fluoride
  • The flame will make the refrigerant evaporate too quickly
  • Open flames are only dangerous with CFCs, not HFCs

Question 25: How long is an EPA Section 608 technician certification valid?

  • Valid for 1 year, must be renewed annually
  • It never expires — certification is permanent once earned
  • Valid for 5 years, then a refresher exam is required
  • Valid until age 65
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit45 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)