EPA 608 Core Exam Practice Test 11

Free EPA 608 Practice Test ( CORE Exam)-11

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 23 min for 15 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

How to Use This Practice Test

This EPA 608 Core Exam Practice Test 11 has 15 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: The EPA 608 exam is NOT open book — memorize refrigerant ODP/GWP values and recovery rules before the exam.

  • Topics covered: Refrigerant regulations, recovery procedures, leak detection, and refrigerant properties.
  • Passing score: 70% required on each section. Universal certification requires passing all four sections.
  • Questions: 15 multiple-choice, one correct answer each
15
Questions
23 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608 · NEC 2023
EPA 608 Core Exam Practice Test 11
Q1 / 15
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 11 — Question List

Question 1: …………… blend refrigerant does not exhibit temperature glide and acts as a single refrigerant.

  • Alkylbenzene
  • Zeotropic
  • Azeotropic
  • Near-azeotropic

Question 2: If corrosion found on the relief valve body then immediately ………

  • It needs to be replaced
  • It needs to repaired
  • It needs to be cleaned
  • It needs to be reconditioned

Question 3: When a system pressure increases even after the evacuation then ………

  • The system is ready to be charged
  • An expansion valve is clogged
  • They system may be leaking
  • A mal operation in compressor motor

Question 4: The recovery equipment that depends on the pressure in the refrigeration system is ……….

  • System-dependant
  • Self dependant
  • Self contained
  • Illegal to use

Question 5: The frost formed on evaporator fins will acts as …………….. between evaporator heat exchanger and surrounding air.

  • Insulator
  • Conductor
  • Semi conductor

Question 6: The accumulator placed in the refrigeration circuit to  …………………… directly passing in to the compressor

  • remove the moisture from the refrigerant
  • prevent the slug of the refrigerant
  • control the refrigerant
  • filter the refrigerant

Question 7: The pressure of the refrigerant at the compressor discharge compared to refrigerant pressure at evaporator outlet is …………….

  • Higher
  • Lower
  • Same
  • None

Question 8: The compound gauge reads the vacuum in the system in ……….

  • Pounds per Square Inch (PSIG)
  • Inches of mercury (in.Hg)
  • Pounds per Square Inch absolute (PSIA)
  • Kilo Pascal (Kpa)

Question 9: The nitrogen should not be added to a fully charged system for the purpose of leak detection.

  • True
  • False

Question 10: From which year on wards the sale of CFC and HCFC refrigerants is restricted to certified technicians.

  • November 14, 1994
  • November 15, 1993
  • October 21, 1995
  • July 2, 1992

Question 11: If you cannot find a leak with any leak detector then

  • charge more refrigerant and increase the pressure which makes the leak sensible by the detector
  • recover the refrigerant and purge with pressurised dry nitrogen to find the leak
  • purge the charged system with dry nitrogen to find the leak
  • add more oil to the system to find the leak.

Question 12: If a technician finds that the refrigerant is mixed

  • he should recover mixture into a separate container
  • he should filter the refrigerant and separate them
  • he should recycle the mixture refrigerant
  • he should separate and reclaim the refrigerant which can later be charged into system.

Question 13: What happens to the time of evacuation if the refrigerant system capacity and gauge set hose size is large?

  • Increases
  • Reduces
  • Does not effect
  • None

Question 14: What are the two ports of recovery cylinders?

  • Liquid and vapour port
  • Low pressure and high pressure liquid ports
  • Low pressure and high pressure vapour ports
  • None

Question 15: The oil is that is recovered during refrigerant recovery

  • It must send to the recovery agency to clean and make it reusable
  • The oil can be recovered to separate cylinder for reuse it
  • The oil cannot be reusable and it should sent for disposable
  • Recover the oil and refrigerant in the same tank which can be reused
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.