Free EPA 608 Core Exam Practice Test 11. 25 questions covering azeotropic blend characteristics, corroded relief valves, post-evacuation pressure rise, system-dependent vs self-contained recovery, evaporator frost, accumulators, discharge pressure, compound gauge vacuum reading, nitrogen in charged systems, refrigerant purchase certification, leak detection, mixed refrigerant handling, evacuation time factors, recovery cylinder ports, recovered oil disposal, AHRI 700 purity, record-keeping requirements, recovery levels, refrigerant density, phosgene from CFC combustion, UV radiation effects, global warming potential, R-22 vs CFC ozone impact, and purge units.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Key facts for this test: Only certified technicians may purchase CFC and HCFC refrigerant (as of November 14, 1994). After evacuation, if pressure rises, the system has a leak. Self-contained recovery equipment has its own compressor and does not depend on system pressure. Refrigerant vapors are heavier than air and settle in low areas — always ventilate the work area. Burning CFCs or HCFCs in an open flame creates phosgene gas (COCl₂), which is highly toxic. GWP measures a gas's heat-trapping ability over 100 years compared to CO₂ (baseline = 1).

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Core Exam Practice Test 11
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 11 — Question List

Question 1: …………… blend refrigerant does not exhibit temperature glide and acts as a single refrigerant.

  • Alkylbenzene
  • Zeotropic
  • Azeotropic
  • Near-azeotropic

Question 2: If corrosion found on the relief valve body then immediately ………

  • It needs to be replaced
  • It needs to repaired
  • It needs to be cleaned
  • It needs to be reconditioned

Question 3: When a system pressure increases even after the evacuation then ………

  • The system is ready to be charged
  • An expansion valve is clogged
  • They system may be leaking
  • A mal operation in compressor motor

Question 4: The recovery equipment that depends on the pressure in the refrigeration system is ……….

  • System-dependant
  • Self dependant
  • Self contained
  • Illegal to use

Question 5: The frost formed on evaporator fins will acts as …………….. between evaporator heat exchanger and surrounding air.

  • Insulator
  • Conductor
  • Semi conductor

Question 6: The accumulator placed in the refrigeration circuit to  …………………… directly passing in to the compressor

  • remove the moisture from the refrigerant
  • prevent the slug of the refrigerant
  • control the refrigerant
  • filter the refrigerant

Question 7: The pressure of the refrigerant at the compressor discharge compared to refrigerant pressure at evaporator outlet is …………….

  • Higher
  • Lower
  • Same
  • None

Question 8: The compound gauge reads the vacuum in the system in ……….

  • Pounds per Square Inch (PSIG)
  • Inches of mercury (in.Hg)
  • Pounds per Square Inch absolute (PSIA)
  • Kilo Pascal (Kpa)

Question 9: The nitrogen should not be added to a fully charged system for the purpose of leak detection.

  • True
  • False

Question 10: From which year on wards the sale of CFC and HCFC refrigerants is restricted to certified technicians.

  • November 14, 1994
  • November 15, 1993
  • October 21, 1995
  • July 2, 1992

Question 11: If you cannot find a leak with any leak detector then

  • charge more refrigerant and increase the pressure which makes the leak sensible by the detector
  • recover the refrigerant and purge with pressurised dry nitrogen to find the leak
  • purge the charged system with dry nitrogen to find the leak
  • add more oil to the system to find the leak.

Question 12: If a technician finds that the refrigerant is mixed

  • he should recover mixture into a separate container
  • he should filter the refrigerant and separate them
  • he should recycle the mixture refrigerant
  • he should separate and reclaim the refrigerant which can later be charged into system.

Question 13: What happens to the time of evacuation if the refrigerant system capacity and gauge set hose size is large?

  • Increases
  • Reduces
  • Does not effect
  • None

Question 14: What are the two ports of recovery cylinders?

  • Liquid and vapour port
  • Low pressure and high pressure liquid ports
  • Low pressure and high pressure vapour ports
  • None

Question 15: The oil is that is recovered during refrigerant recovery

  • It must send to the recovery agency to clean and make it reusable
  • The oil can be recovered to separate cylinder for reuse it
  • The oil cannot be reusable and it should sent for disposable
  • Recover the oil and refrigerant in the same tank which can be reused

Question 16: Reclaimed refrigerant must meet __________ purity standards before it can be resold or used in another owner's equipment.

  • ASHRAE Standard 15
  • AHRI Standard 700
  • DOT Standard 4BA
  • EPA Standard 608

Question 17: Under EPA Section 608 regulations, which appliance owners are required to keep records of refrigerant service?

  • All appliance owners regardless of charge size
  • Owners of appliances with a refrigerant charge of 50 pounds or more
  • Only owners of commercial refrigeration equipment
  • Record-keeping is voluntary, not required

Question 18: What is the required refrigerant recovery level for a high-pressure system manufactured BEFORE November 15, 1993, with a charge LESS than 200 pounds?

  • 15 in.Hg vacuum
  • 0 psig (recover to atmospheric pressure)
  • 10 in.Hg vacuum
  • 4 in.Hg vacuum

Question 19: What is the key feature of self-contained refrigerant recovery equipment that makes it different from system-dependent recovery equipment?

  • It uses the system's compressor to push refrigerant out
  • It has its own motor and compressor
  • It filters and reclaims refrigerant to AHRI 700 standards
  • It works only on low-pressure systems

Question 20: Refrigerant vapor is heavier than air. What safety risk does this create?

  • Refrigerant floats to the ceiling and is harmless
  • Refrigerant accumulates at floor level and can displace oxygen, causing asphyxiation
  • Refrigerant ignites more easily when mixed with air
  • Refrigerant becomes more toxic when near the floor

Question 21: What dangerous gas is produced when CFC or HCFC refrigerant contacts an open flame?

  • Carbon monoxide (CO)
  • Phosgene gas (COCl₂)
  • Hydrogen fluoride (HF)
  • Chlorine gas (Cl₂)

Question 22: Depletion of the stratospheric ozone layer leads to increased UV radiation reaching Earth's surface. Which health effects are linked to increased UV exposure?

  • Increased respiratory disease and acid rain
  • Increased rates of skin cancer and cataracts
  • Greenhouse effect and global warming only
  • No significant health effects — UV-B is harmless

Question 23: What does GWP (Global Warming Potential) measure?

  • How fast a gas destroys ozone compared to R-11
  • How much heat a gas traps in the atmosphere over 100 years compared to CO₂
  • The flammability rating of a refrigerant gas
  • The toxicity level of a refrigerant at normal concentrations

Question 24: R-22 (HCFC-22) has a LOWER ozone depletion potential (ODP) than CFC refrigerants like R-11 and R-12. Why is R-22 still being phased out?

  • R-22 is not being phased out — only CFCs are regulated
  • Because R-22 still depletes ozone (ODP = 0.055) and has significant GWP
  • Because R-22 is highly flammable
  • Because R-22 contains hydrogen which is harmful

Question 25: What is the purpose of a purge unit on a Type III (low-pressure) refrigeration system such as a centrifugal chiller using R-11 or R-123?

  • To recover refrigerant when the system is opened for service
  • To remove non-condensable gases (air, nitrogen) that leak into the system
  • To filter oil out of the refrigerant
  • To control the refrigerant flow rate through the expansion valve
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit45 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)