EPA 608 Core Exam Practice Test 12

Free EPA 608 Core Exam Practice Test 12. 25 questions covering refrigerant cylinder transport, relief valve series installation, CFC recovery after 1995, disposable cylinders, CFC and HFC recovery requirements, ozone layer UV protection, ozone depleting substances, evaporator phase change, ternary blends, compound gauge measurements, mixing refrigerants, dehydration, vapor compression cooling, sight glass function, compressor oil types, CFC structure, global warming potential, purge units, DOT recovery cylinders, cylinder valve caps, cooling recovery cylinders, electronic leak detector sensitivity, UV health effects, HFC climate impact, and refrigerant terminology.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Key facts for this test: Refrigerant cylinders must always be transported and stored in an upright (vertical) position with valves on top. Relief valves downstream of a nitrogen pressure regulator must be installed in parallel, never in series. After 1995, all CFCs used for servicing existing equipment in the USA must come from recovered or recycled stock — no new CFC production is permitted. Disposable cylinders are for virgin (new) refrigerant only — they must never be used as recovery cylinders.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Core Exam Practice Test 12
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 12 — Question List

Question 1: The refrigerant cylinders always shipped in ……………. position with their valves on top.

  • Vertical
  • Horizontal

Question 2: The relief valves which are placed in the downstream line of nitrogen pressure regulator must not be installed in ………….

  • Series
  • Parallel

Question 3: After which year onwards the CFC refrigerant should come from recovery and recycling to service existing refrigeration systems in USA?

  • 1995
  • 1992
  • 1997
  • 1994

Question 4: Disposable cylinders are primarily used for ………….. refrigerant

  • Recovered
  • Recycled
  • Virgin
  • Fresh

Question 5: CFC and HFC both have which of the following in common?

  • They both have higher ODP
  • They both must be recovered before recycling or disposing the appliance
  • The both contain chlorine atom which destroys the ozone
  • Their normal boiling point is same.

Question 6: The ozone layer in the earth’s stratosphere protects the earth from ………..

  • UV radiation
  • Infrared radiation
  • Nuclear radiation
  • Poisoned gases

Question 7: Which of the following is not a ozone depleting substances (ODS)?

  • methyl chloroform
  • methyl oxide
  • halons
  • chlorofluorocarbon

Question 8: In refrigeration system low pressure liquid is converted into low pressure vapour in …….

  • Accumulator
  • Condenser
  • Metering device
  • Evaporator

Question 9: ……………. mixture is called as ternary refrigerant blend.

  • Two-part
  • Three-part
  • Five-part
  • Six-part

Question 10: A compound gauge connected to low side of the refrigeration system measures the pressure in ……

  • Psig and in.hg
  • Psig and microns
  • Microns
  • Psia

Question 11: Any two refrigerants should not be mixed because

  • It is impossible to reclaim any mixture
  • It is impossible recover the mixture in same container
  • They may explode
  • The mixture may lead to corrosive

Question 12: Removing water vapor from refrigeration system is called as ….

  • Condensation
  • Evaporation
  • dehydration
  • Expansion

Question 13: The cooling occurs in vapor compression cycle refrigeration system, when …..

  • The refrigerant changes from liquid to vapor
  • The refrigerant changes from vapor to liquid
  • The refrigerant pressure increases
  • The refrigerant temperature decreases

Question 14: What is the purpose of a sight glass installed in the liquid line of a refrigeration system?

  • To measure the refrigerant pressure in the liquid line
  • To show the state of the refrigerant (bubbles indicate low charge or restriction)
  • To separate liquid refrigerant from oil
  • To control the amount of refrigerant entering the evaporator

Question 15: Which compressor lubricating oil is typically used with CFC refrigerants such as R-12?

  • POE (polyolester) oil
  • Mineral oil
  • Alkylbenzene (AB) oil
  • PAG (polyalkylene glycol) oil

Question 16: Which elements does a CFC (chlorofluorocarbon) refrigerant contain?

  • Hydrogen, carbon, chlorine, and fluorine
  • Carbon, chlorine, and fluorine only — no hydrogen
  • Carbon, fluorine, and oxygen only
  • Hydrogen and fluorine only

Question 17: Which term describes refrigerant that has been cleaned and tested to meet AHRI Standard 700 purity and can be resold or used in a different owner's equipment?

  • Recovered refrigerant
  • Reclaimed refrigerant
  • Recycled refrigerant
  • Virgin refrigerant

Question 18: Recovery cylinders used for refrigerant must meet which DOT (Department of Transportation) cylinder specification?

  • DOT 3A or DOT 3AA
  • DOT 4BA or DOT 4BW
  • Any standard propane cylinder is acceptable
  • No specific DOT rating is required for refrigerant cylinders

Question 19: Why must the valve cap (protective cap) always be replaced on a refrigerant cylinder after each use?

  • Valve caps are optional — just a convenience
  • To protect the valve from damage and prevent accidental refrigerant release
  • The cap helps keep the refrigerant cold during storage
  • To identify that the cylinder has been used

Question 20: Why does cooling the recovery cylinder speed up the refrigerant recovery process?

  • Cooling makes the refrigerant molecules move faster into the cylinder
  • A cooler cylinder has lower internal pressure, creating a larger pressure difference and faster flow
  • Cooling the cylinder removes moisture from the refrigerant
  • A cold cylinder holds more refrigerant by weight than a warm cylinder

Question 21: Under EPA Section 608 regulations, what is the minimum sensitivity required for an electronic refrigerant leak detector used to verify repairs?

  • 50 grams per year
  • 5 grams per year
  • 500 grams per year
  • 0.5 grams per year

Question 22: Ozone depletion leads to increased ultraviolet (UV) radiation at Earth's surface. What health conditions are directly linked to increased UV-B exposure?

  • Lung cancer and cardiovascular disease
  • Skin cancer and cataracts
  • Diabetes and liver disease
  • Increased UV radiation has no health effects on humans

Question 23: HFC refrigerants (such as R-134a and R-410A) have zero ODP. Why are they still considered an environmental concern?

  • HFCs still contain chlorine, so they still damage the ozone layer
  • HFCs have a high GWP and contribute to climate change
  • HFCs are highly flammable at normal operating conditions
  • HFCs are no longer a concern now that the Montreal Protocol is in place

Question 24: CFC refrigerant production was completely phased out in the United States at the end of which year?

  • 1987
  • 1995
  • 1992
  • 2000

Question 25: Before adding refrigerant from an unknown or unlabeled cylinder to a system, a technician should use __________ to check what refrigerant is in the cylinder.

  • A manifold gauge set to check the pressure
  • A refrigerant identifier (analyzer)
  • A thermometer to check the boiling point
  • The label on the cylinder is always sufficient
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit45 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)