NEC CODE NEC 2023

Commercial load Calculations (NEC Code Questions)

Free NEC Code Questions and Answers ( Commercial Load Calculations)

TOPICS COVERED
NEC Questions

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 14 min for 9 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — free, no signup required. Each question links to the relevant NEC article so you can study the code directly.

The National Electrical Code (NFPA 70) is the benchmark standard for safe electrical installation in the US. It is updated every 3 years by the NFPA.

Study the edition adopted by your state. As of 2025, most states use the 2020 or 2023 NEC. These tests are written to the 2023 edition.

The most tested articles are 100 (Definitions), 200–250 (Wiring & Grounding), 300–314 (Wiring Methods), 400–411 (Conductors), 430 (Motors), and 700–701 (Emergency Systems).
9
Questions
14 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC CODE · NEC 2023
Commercial load Calculations (NEC Code Questions)
Q1 / 9
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

Commercial load Calculations (NEC Code Questions) — Question List

Question 1: After the demand factor is applied , what is the general lighting load of a hospital which is having 80,000 sq ft area?

  • 42,000 VA
  • 1,60,000 VA
  • 58,000 VA
  • 82, 000 VA

NEC Reference: NEC 220.12

Question 2: The feeder/service demand load for show window lighting must be …………….. per each linear ft.

  • 200 VA
  • 150 VA
  • 100 VA
  • 250 VA

NEC Reference: NEC 220.14(G)

Question 3: The show window lighting must be treated as ……………….

  • Continuous load
  • Non- continuous load

Question 4: In a non dwelling unit the load for general use receptacle is ………….. per yoke

  • 150 VA
  • 180 VA
  • 200 VA
  • 250 VA

NEC Reference: NEC 220.14(G)

Question 5: How many number of receptacle outlets are permitted on a commercial building circuit which is having a computed lighting load of 3400 VA?

  • 20
  • 28
  • 19
  • 16

NEC Reference: NEC 220.14(G)

Question 6: The recreational park is having fifteen 20 A supply facilities, ten 20A and 30 A supply facilities and twenty five 50A supply facilities is operated at 120/240 V single phase. What is the service demand load for the recreational park?

  • 480 A
  • 533 A
  • 686 A
  • 564 A

NEC Reference: NEC 551.73(A)

Question 7: The mobile home park which has 25 site facilities is fed from a 240 V service feeder. What is the demand load for mobile home park?

  • 400 A
  • 450 A
  • 500 A
  • 380 A

NEC Reference: NEC 550.31

Question 8: What is general lighting unit load per square feet for hotels and guest room?

  • 3 VA
  • 2 VA
  • 2 ½ VA
  • 1 VA

NEC Reference: NEC 220.12

Question 9: What is the load of 12000 sq ft warehouse after the demand factors are applied?

  • 3000 VA
  • 2500 VA
  • 2000 VA
  • 2250 VA

NEC Reference: NEC 220.12

EXAM CARD NEC CODE
Questions9
Time limit14 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate

Timer starts immediately. Progress is auto-saved.