Transformer Calculations NEC code Questions

Free Online Practice Test on Transformer Calculations

TOPICS COVERED
NEC Questions

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 10 min for 6 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — free, no signup required. Each question links to the relevant NEC article so you can study the code directly.

The National Electrical Code (NFPA 70) is the benchmark standard for safe electrical installation in the US. It is updated every 3 years by the NFPA.

Study the edition adopted by your state. As of 2025, most states use the 2020 or 2023 NEC. These tests are written to the 2023 edition.

The most tested articles are 100 (Definitions), 200–250 (Wiring & Grounding), 300–314 (Wiring Methods), 400–411 (Conductors), 430 (Motors), and 700–701 (Emergency Systems).
6
Questions
10 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC CODE · NEC 2023
Transformer Calculations NEC code Questions
Q1 / 6
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

Transformer Calculations NEC code Questions — Question List

Question 1: The "Next up size" protection rule is not applicable when sizing over current protection device of transformer secondary conductors.

  • True
  • False

NEC Reference: NEC 240.4(B)

Question 2: What is the primary over current device rating of a 2 wire 480 V to 120 V transformer rated at 1.8 KVA?

  • 6 A
  • 7 A
  • 4 A
  • 10 A

NEC Reference: NEC 450.3

Question 3: What is the primary protection required for a 2 wire 480V to 120 V Transformer rated at 900 VA?

  • 5 A
  • 6 A
  • 4 A
  • 3 A

NEC Reference: NEC 450.3

Question 4: What is the rating of primary over current protection device required for a 2 wire 480V to 120 V transformer rated at 7KVA?

  • 15 A fuse
  • 20 A fuse
  • 25 Fuse
  • 10 A Fuse

NEC Reference: NEC 14.58

Question 5: What is the minimum size secondary conductor is required for a 2 wire 480V to 120 V transformer rated 2.2 KVA with 60<sup>0</sup>C terminals?

  • 12 AWG
  • 14 AWG
  • 8 AWG
  • 10 AWG

NEC Reference: NEC 18.33

Question 6: Dry type transformer rated more than ............... are permitted to install in hollow spaces of buildings.

  • 50 KVA
  • 100 KVA
  • 85 KVA
  • 75 KVA

NEC Reference: NEC 450.13(A)