BASIC NEC 2023

Service conductor practice test questions-1

Take a Practice test on Service conductor  Practice quiz questions - 1

TOPICS COVERED
NEC Questions

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 15 min for 10 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.
10
Questions
15 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

BASIC · NEC 2023
Service conductor practice test questions-1
Q1 / 10
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

Service conductor practice test questions-1 — Question List

Question 1: what is the smallest copper wire size that can be used for service entrance conductors?

  • 8 AWG
  • 6 AWG
  • 10 AWG
  • 12 AWG

NEC Reference: NEC 230.31(B)

Question 2: In a three phase balanced 4-wire system, the current in the neutral conductor .....................

  • is same as un-grounded conductor
  • is lower than other conductors
  • is higher than other conductos
  • will not flow as the circuit is balanced

Question 3: What is the minimum size electrical service required for a single family dwelling unit?

  • 100 amperes
  • 150 amperes
  • 200 amperes
  • 50 amperes

NEC Reference: NEC 230.79(C)

Question 4: For each service , what are the maximum allowable service dis-connectors?

  • 4
  • 2
  • 6
  • 8

NEC Reference: NEC 230.71(A)

Question 5: What is the minimum vertical clearance that should be provided for service conductors from the height point of over which they pass?

  • 6 feet
  • 8 feet
  • 10 feet
  • 12 feet

NEC Reference: NEC 230.24(A)

Question 6: The 400 volts over head conductors that passes over public street must have a clearance of ..........

  • 15 feet
  • 10 feet
  • 24 feet
  • 18 feet

NEC Reference: NEC 230.24(B)(4)

Question 7: When multi conductor cables are used as overhead service conductors, they must be attached to building or other structures by ............................

  • Tie wires
  • Safe enclosures
  • fittings approved for the purpose
  • proper long nails

NEC Reference: NEC 230.27

Question 8: Service entrance cables shall be supported by strops with in ................. distance of every service head.

  • 24 inches
  • 36 inches
  • 12 inches
  • 15 inches

NEC Reference: NEC 230.51(A)

Question 9: The metal enclosures used for service conductor and equipment ..................

  • must never be grounded
  • must be grounded
  • should be coated with non conducting material
  • should have clearance of 30 inches b/w enclosure and equipment

NEC Reference: NEC 250.80

Question 10: What size service conductor is required for a 120/240 volts single phase with a demand load of 48 KVA?

  • 200 amperes
  • 150 amperes
  • 100 amperes
  • 250 amperes