Free Online Journeyman Electrician Practice Test — NEC 2020 Edition 8This free 30-question practice test covers service entrance and disconnect rules, transformer overcurrent protection and installation, and GFCI/AFCI protection requirements, including the dishwasher and laundry area GFCI rules newly added in the 2020 NEC. All questions are based on the 2020 NEC.

TOPICS COVERED
journeyman electrician

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account required. All questions include detailed explanations and NEC references.

Most state Journeyman exams have 80–100 questions covering NEC code, wiring methods, branch circuits, motor controls, and load calculations.

Most states require a 70–75% passing score. This practice test uses the same 70% pass threshold so you know where you stand.

Questions are written to the 2020 NEC. Check your state licensing board to confirm which edition your state has adopted.

How to Use This Practice Test

This NEC 2020 Journeyman Practice Test 8 has 30 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: This is an open-book exam — tab your NEC index and Articles 210, 250, and 430 before you start.

  • Topics covered: Branch circuits, grounding, wiring methods, load calculations, and motors.
  • Passing score: 70–75% (most states). Aim for 80% on practice tests so the real exam feels easy.
  • Questions: 30 multiple-choice, one correct answer each
30
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

JOURNEYMAN · NEC 2020
NEC 2020 Journeyman Practice Test 8
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC 2020 Journeyman Practice Test 8 — Question List

Question 1: Per NEC 230.70(A)(1), the service disconnecting means must be installed at a location that is:

  • Readily accessible, nearest the point of entrance of the service conductors
  • In the attic, regardless of accessibility
  • In a locked closet requiring a special key
  • At least 100 feet from the point of service entrance

NEC Reference: NEC 230.70(A)(1)

Question 2: Per NEC 230.24(B), what is the minimum vertical clearance required for service-drop conductors over residential property and driveways, where the voltage does not exceed 300 volts to ground?

  • 8 feet
  • 10 feet
  • 12 feet
  • 18 feet

NEC Reference: NEC 230.24(B)(1)

Question 3: Per NEC 230.71(B), the service disconnecting means for each service permitted by 230.2 may consist of not more than how many switches or circuit breakers grouped at one location?

  • Two
  • Four
  • Six
  • Eight

NEC Reference: NEC 230.71(B)

Question 4: Per NEC 230.79(C), what is the minimum rating required for the service disconnecting means of a one-family dwelling?

  • 60 amperes
  • 100 amperes
  • 150 amperes
  • 200 amperes

NEC Reference: NEC 230.79(C)

Question 5: Per NEC 230.90(A), overload protection for service conductors must be provided:

  • In each ungrounded service conductor
  • Only on the grounded (neutral) conductor
  • Only at the utility transformer
  • Only where the service exceeds 400 amperes

NEC Reference: NEC 230.90(A)

Question 6: Per NEC 230.95, ground-fault protection of equipment (GFPE) is required for service disconnects rated 1000 amperes or more on solidly grounded wye systems where the voltage to ground:

  • Exceeds 150 volts to ground but does not exceed 600 volts phase-to-phase
  • Is exactly 120 volts to ground
  • Is below 50 volts to ground
  • Does not matter — GFPE is required on every service

NEC Reference: NEC 230.95

Question 7: Per the definitions in NEC Article 100, the "service point" is best described as:

  • The point of connection between the utility and the premises wiring
  • The main panel inside the building
  • The meter base only
  • Any junction box on the property

NEC Reference: NEC Article 100

Question 8: Per NEC 230.24(B)(2), what minimum vertical clearance is required for service-drop conductors over public streets, alleys, roads, and areas subject to truck traffic?

  • 10 feet
  • 12 feet
  • 15 feet
  • 18 feet

NEC Reference: NEC 230.24(B)(2)

Question 9: A dry-type transformer rated 600 volts or less has a primary full-load current of 20 amperes and is protected only on the primary side. Per NEC Table 450.3(B), the primary overcurrent device must not exceed what percentage of the primary current?

  • 100 percent
  • 125 percent
  • 167 percent
  • 250 percent

NEC Reference: NEC Table 450.3(B)

Question 10: A control transformer has a primary full-load current of less than 9 amperes and is protected only on the primary side. Per NEC Table 450.3(B), the primary overcurrent device may be set up to what percentage of primary current?

  • 125 percent
  • 150 percent
  • 167 percent
  • 200 percent

NEC Reference: NEC Table 450.3(B)

Question 11: Per NEC 450.9, transformers must be installed so that:

  • Adequate ventilation is provided to dissipate the transformer's full-load losses
  • They are always installed outdoors regardless of type
  • No airflow clearance is needed for dry-type units
  • They may be fully enclosed in a sealed, unventilated box

NEC Reference: NEC 450.9

Question 12: Per NEC 240.21(C)(6), the 25-foot secondary conductor tap rule for transformers allows secondary conductors to run up to 25 feet without overcurrent protection at the transformer, provided which condition is met?

  • The secondary conductor ampacity, adjusted by the transformer's turns ratio, is at least equal to the primary OCPD rating, with physical protection and a single terminating OCPD
  • The conductors may be any length as long as they are copper
  • No ampacity relationship to the primary OCPD is required
  • Overcurrent protection is never required anywhere on the secondary

NEC Reference: NEC 240.21(C)(6)

Question 13: Per NEC 450.21(A), a dry-type transformer rated 112.5 kVA or less, installed indoors, must be separated from combustible material by at least:

  • 6 inches
  • 12 inches
  • 24 inches
  • 36 inches

NEC Reference: NEC 450.21(A)

Question 14: True or false: per NEC 210.8(A)(1), all 125-volt, 15- and 20-ampere receptacles installed in dwelling unit bathrooms must have GFCI protection.

  • True
  • False
  • Only in half-bathrooms
  • Only if the bathroom has a bathtub

NEC Reference: NEC 210.8(A)(1)

Question 15: Per NEC 210.8(A)(2), GFCI protection is required for 125-volt, 15- and 20-ampere receptacles in which of these dwelling locations?

  • Garages and grade-level accessory buildings
  • Only heated living spaces
  • Only the second floor of a dwelling
  • Only formal dining rooms

NEC Reference: NEC 210.8(A)(2)

Question 16: Per NEC 210.8(A)(6), GFCI protection is required for dwelling unit receptacles that:

  • Serve kitchen countertop surfaces
  • Are located in a hallway closet
  • Supply a hardwired smoke detector
  • Are located above 6.5 feet in a garage

NEC Reference: NEC 210.8(A)(6)

Question 17: Per NEC 210.8(A)(7), GFCI protection is required for receptacles installed within what distance of the outside edge of any sink (not just kitchen sinks)?

  • 3 feet
  • 6 feet
  • 10 feet
  • 12 feet

NEC Reference: NEC 210.8(A)(7)

Question 18: The 2020 NEC added a brand-new requirement in 210.8(D) for GFCI protection on outlets supplying which dwelling unit appliance?

  • Garbage disposals
  • Dishwashers
  • Refrigerators
  • Range hoods

NEC Reference: NEC 210.8(D)

Question 19: The 2020 NEC expanded the list in 210.8(A) to newly require GFCI protection for dwelling unit receptacles located in which area, not previously listed?

  • Laundry areas
  • Formal living rooms
  • Attics with no equipment
  • Interior hallways

NEC Reference: NEC 210.8(A)(10)

Question 20: Per NEC 210.8(A)(9), GFCI protection is required for receptacles installed within what distance of the outside edge of a bathtub or shower stall?

  • 3 feet
  • 6 feet
  • 8 feet
  • 10 feet

NEC Reference: NEC 210.8(A)(9)

Question 21: Per NEC 406.4(D)(2), when a non-grounding-type receptacle is replaced with a GFCI receptacle where no equipment ground exists, the new receptacle must be marked:

  • "No Equipment Ground"
  • "Danger — High Voltage"
  • "Tamper Resistant"
  • No marking is required

NEC Reference: NEC 406.4(D)(2)

Question 22: True or false: per NEC 210.12(A), 120-volt, 15- and 20-ampere branch circuits supplying outlets in dwelling unit bedrooms must have arc-fault circuit-interrupter (AFCI) protection.

  • True
  • False
  • Only in basement bedrooms
  • Only for circuits over 20 amperes

NEC Reference: NEC 210.12(A)

Question 23: Besides bedrooms, NEC 210.12(A) also requires AFCI protection for 120-volt, 15- and 20-ampere circuits supplying outlets in which of the following dwelling unit areas?

  • Kitchens, family rooms, dining rooms, living rooms, and similar habitable rooms
  • Only unfinished attics
  • Only exterior receptacles
  • Only detached garages

NEC Reference: NEC 210.12(A)

Question 24: Per NEC 210.12(A), the required AFCI protection for dwelling unit branch circuits must be provided by which type of device?

  • A listed combination-type AFCI device
  • Any GFCI receptacle
  • A standard thermal-magnetic breaker
  • A fuse rated for arc protection

NEC Reference: NEC 210.12(A)

Question 25: True or false: a laundry area receptacle outlet in a dwelling unit can be required to have BOTH GFCI protection (per 210.8) and AFCI protection (per 210.12) at the same time.

  • True
  • False
  • Only in commercial laundries
  • Only if the circuit is over 30 amperes

NEC Reference: NEC 210.8(A) / 210.12(A)

Question 26: Per NEC 210.12(B), when an existing branch circuit serving one of the areas listed in 210.12(A) is extended or modified, what is generally required?

  • The extended/modified circuit must receive AFCI protection by a listed method
  • No AFCI protection is ever required for existing circuit work
  • Only the new outlet needs protection, never the rest of the circuit
  • AFCI protection is optional at the homeowner's discretion

NEC Reference: NEC 210.12(B)

Question 27: True or false: per NEC 210.8(A)(3), all 125-volt, 15- and 20-ampere receptacles installed outdoors at a dwelling unit require GFCI protection.

  • True
  • False
  • Only front-yard receptacles
  • Only receptacles mounted below 3 feet

NEC Reference: NEC 210.8(A)(3)

Question 28: Per NEC 210.8(A)(4), GFCI protection is required for receptacles installed in which type of crawl space?

  • Crawl spaces at or below grade level
  • Only crawl spaces above the second floor
  • Only heated, finished crawl spaces
  • No crawl space ever requires GFCI protection

NEC Reference: NEC 210.8(A)(4)

Question 29: Per NEC 210.8(A)(5), GFCI protection is required for receptacles in unfinished portions of a dwelling unit basement, but which specific spaces are exempt from this requirement?

  • Receptacles dedicated to a permanently installed fire or burglar alarm system
  • Receptacles used for holiday lighting
  • Receptacles for a sump pump
  • Receptacles mounted above 6 feet

NEC Reference: NEC 210.8(A)(5)

Question 30: Which statement correctly distinguishes the purpose of a GFCI device from an AFCI device?

  • GFCI protects against shock from ground faults; AFCI protects against fire from arcing faults
  • They are two names for the exact same protective function
  • GFCI protects against fire; AFCI protects against shock
  • Neither device relates to personnel or fire safety

NEC Reference: NEC Article 100

Key NEC References for This Test

ArticleWhat It Covers
Art. 100Definitions — know: feeder, branch circuit, OCPD, dwelling unit
Art. 210Branch Circuits — GFCI/AFCI locations, circuit ratings, outlet spacing (most tested)
Art. 220Load Calculations — dwelling unit standard method
Art. 250Grounding & Bonding — GEC sizing, electrode system, EGC
Art. 310Conductors — ampacity (Table 310.12), insulation, derate rules
Art. 430Motors — conductor 125% FLA, OCPD 250% FLA, overloads, disconnects
Study Tip: Tab Articles 210, 250, and 430 in your NEC before the exam. Know the Table 310.12 ampacity values for 14, 12, 10, 8, 6, and 4 AWG copper.
EXAM CARD JOURNEYMAN
Questions30
Time limit45 min
Pass score70%
Code editionNEC 2020
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)