NATE_CORE NEC 2023

NATE Core Practice Test 7

This practice test covers temperature and humidity measurement from the NATE Core exam blueprint. You will see questions on dry bulb and wet bulb temperature, relative humidity, the psychrometric chart, and the sling psychrometer.

TOPICS COVERED
NATE Core

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 30 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no signup required. Every question includes a full explanation of the correct answer.

Two: the NATE Core exam plus at least one specialty exam (for example AC Service, Heat Pump Service, or Air Distribution Service). You can take them on the same day or separately.

The Core exam has 50 questions and each installation or service specialty exam has 100 questions. You need 70% on each to pass — 35 of 50 on Core and 70 of 100 on a specialty. Check natex.org for the current format before you book.

NATE certification lasts two years. To renew, you submit 16 hours of continuing education or retake the specialty exam before your certification expires.

No. These are independent practice tests written to match the published NATE exam topics. They are not official NATE exam questions.

Exam Tip: Remember that the wet bulb reading is always equal to or lower than the dry bulb reading. The bigger the gap between them, the lower the relative humidity.

30
Questions
30 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NATE_CORE · NEC 2023
NATE Core Practice Test 7
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NATE Core Practice Test 7 — Question List

Question 1: What does "dry bulb temperature" mean?

  • The temperature read using a moistened thermometer bulb
  • The temperature of refrigerant only
  • The normal air temperature reading, taken with an ordinary thermometer
  • The temperature of a solid surface only

Question 2: What does "wet bulb temperature" mean?

  • The temperature setting on a humidifier
  • The temperature of water in a drain pan
  • The average of the high and low temperature for the day
  • The temperature read using a thermometer with a wet, moistened bulb, affected by evaporative cooling

Question 3: What does "relative humidity" measure?

  • The amount of moisture in the air compared to the maximum it could hold at that temperature
  • The temperature of the air only
  • The pressure of refrigerant vapor
  • The total weight of water in a home

Question 4: How are dry bulb and wet bulb temperature readings used together?

  • They are added together to get the BTU rating of a system
  • They are compared, often with a psychrometric chart or sling psychrometer, to determine relative humidity
  • They are used only to measure refrigerant pressure
  • They have no relationship to each other

Question 5: What is a "sling psychrometer" used for?

  • Measuring refrigerant pressure
  • Cutting copper tubing
  • Taking wet bulb and dry bulb readings to determine humidity
  • Testing electrical voltage

Question 6: In normal conditions, how does the wet bulb temperature reading compare to the dry bulb temperature reading of the same air?

  • There is no relationship between the two readings
  • The wet bulb reading is always higher than the dry bulb reading
  • They are always exactly the same, with no exceptions
  • The wet bulb reading is equal to or lower than the dry bulb reading

Question 7: What does it mean if relative humidity is at 100%?

  • The air is holding the maximum amount of moisture it can hold at that temperature
  • The air temperature is at its highest possible point
  • The wet bulb thermometer will always read higher than the dry bulb
  • The air contains no moisture at all

Question 8: What is a psychrometric chart used for?

  • Showing the wiring diagram of a thermostat
  • Showing the relationship between temperature, humidity, and other properties of air
  • Showing refrigerant pressure and temperature relationships only
  • Showing the layout of ductwork in a building

Question 9: What is the basic purpose of a thermometer?

  • To measure electrical resistance
  • To measure refrigerant charge
  • To measure temperature
  • To measure air pressure

Question 10: Why does evaporation cause the wet bulb thermometer to read a lower temperature than the dry bulb thermometer?

  • Wet bulb thermometers are simply less accurate than dry bulb thermometers
  • Water always freezes on the wet bulb wick
  • The wet wick blocks all heat from reaching the thermometer
  • Evaporating water absorbs heat from the thermometer bulb, cooling it

Question 11: A technician takes a reading and finds that the wet bulb and dry bulb temperatures are exactly the same. What does this tell the technician?

  • The relative humidity is at or near 100%
  • The air temperature is below freezing
  • There is no humidity in the air at all
  • The thermometer is broken

Question 12: A technician notices a large difference between the dry bulb and wet bulb readings. What does this generally indicate?

  • Higher relative humidity in the air
  • Lower relative humidity in the air
  • The thermometers need to be replaced
  • The refrigerant charge is low

Question 13: Besides traditional glass thermometers, what other common type of thermometer might a technician use in the field?

  • A manifold gauge
  • A tubing cutter
  • A digital thermometer with a probe
  • A torque wrench

Question 14: In what units is relative humidity typically expressed?

  • In BTUs
  • In pounds per square inch
  • In degrees Fahrenheit
  • As a percentage

Question 15: If a technician knows both the dry bulb temperature and the wet bulb temperature, what can a psychrometric chart help them find?

  • The relative humidity and other properties of the air
  • The electrical voltage of the circuit
  • The size of the ductwork needed
  • The exact refrigerant type in the system

Question 16: When a weather report gives today's outdoor temperature, which type of temperature reading is this most similar to?

  • Wet bulb temperature
  • Dry bulb temperature
  • Latent temperature
  • Saturation temperature only

Question 17: Why might a technician measure both temperature and humidity when evaluating how well a cooling system is performing?

  • Humidity has no effect on how a system performs
  • Humidity is only relevant to heating systems, not cooling systems
  • The system needs to manage both temperature (sensible heat) and humidity (latent heat) for good performance
  • Only the wet bulb reading needs to be checked; dry bulb is not important

Question 18: Which type of thermometer reading requires a wet, moistened wick around the sensing bulb?

  • Digital temperature
  • Dry bulb
  • Surface temperature
  • Wet bulb

Question 19: On a very humid summer day, would the gap between the dry bulb and wet bulb temperature readings typically be larger or smaller compared to a dry day?

  • Smaller, because less evaporation happens when the air is already humid
  • It stays exactly the same no matter the humidity
  • The wet bulb reading would be higher than the dry bulb reading
  • Larger, because humid air always evaporates faster

Question 20: Which tool would a technician most likely use to check the surface temperature of a suction line?

  • Manifold gauge
  • Clip-on or probe thermometer
  • Torque wrench
  • Nut driver

Question 21: Why can the same amount of moisture in the air result in different relative humidity readings at different temperatures?

  • Relative humidity never changes with temperature
  • Moisture content and temperature are unrelated to relative humidity
  • Warmer air can hold more moisture, so the same moisture level is a lower percentage of the warmer air's capacity
  • Colder air can always hold more moisture than warm air

Question 22: A technician reads 75 degrees F on a standard thermometer with no wet wick involved. What kind of reading is this?

  • Latent temperature
  • Wet bulb temperature
  • Relative humidity
  • Dry bulb temperature

Question 23: What general concept does "dew point" describe?

  • The temperature at which air becomes fully saturated and moisture begins to condense
  • The pressure at which refrigerant boils
  • The R-value of insulation
  • The exact BTU rating of a furnace

Question 24: Which two temperature readings are needed to determine relative humidity using a sling psychrometer?

  • Supply and return air temperature
  • Dry bulb and wet bulb temperature
  • High-side and low-side pressure
  • Indoor and outdoor temperature

Question 25: A technician records a dry bulb reading of 80 degrees F and a wet bulb reading of 67 degrees F, a noticeable gap between the two. What does this gap generally suggest about the relative humidity?

  • The relative humidity is at exactly 100%
  • The relative humidity cannot be estimated from these two readings
  • The relative humidity is less than 100%, and a noticeable gap suggests it is not extremely high
  • The air contains no moisture at all

Question 26: What is the main difference between measuring air temperature and measuring the surface temperature of a pipe?

  • Air temperature can only be measured with a wet bulb thermometer
  • There is no difference; both use the exact same method
  • Surface temperature can only be measured with a manifold gauge
  • Air temperature is measured with the sensor in the airstream; surface temperature is measured with the sensor touching or clamped to the pipe

Question 27: True or False: The wet bulb temperature reading can never be higher than the dry bulb temperature reading for the same air sample.

  • True
  • False, there is no relationship between the two
  • False, it depends only on the thermometer brand
  • False, wet bulb is always higher

Question 28: Why do HVACR technicians measure both temperature and humidity when checking system performance?

  • Because only humidity actually matters
  • Because both affect comfort and system performance together
  • Because temperature and humidity are the exact same measurement
  • Because it is required by the manufacturer's paint warranty

Question 29: Why does a technician swing a sling psychrometer through the air before taking a reading?

  • To warm up the thermometers before use
  • To mix the refrigerant inside the unit
  • To move air across the wet wick so it can evaporate properly and give an accurate wet bulb reading
  • To clean dust off the thermometers

Question 30: What two things does a technician need to determine relative humidity using a psychrometric chart?

  • The R-value and the BTU rating
  • The refrigerant type and the system's tonnage
  • The voltage and the amperage
  • The dry bulb temperature and the wet bulb temperature
EXAM CARD NATE_CORE
Questions30
Time limit30 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)