Master Electrician Practice Test 30 – GFCI/AFCI Requirements & Feeders Deep Dive

This is Master Electrician Practice Test 30 — GFCI/AFCI Requirements & Feeders Deep Dive, the final test in this practice series. It covers the full dwelling-unit GFCI location list, the AFCI-protected room list, multiwire branch circuit disconnect rules, and feeder sizing under Article 215. The test has 25 multiple-choice questions on where GFCI and AFCI protection is required, how multiwire branch circuits must be disconnected, and how to size a feeder for combined continuous and noncontinuous loads. Pass score is 70%. Every question includes a full NEC 2023 explanation so you can trace each answer back to the exact code section.

TOPICS COVERED
GFCI/AFCI & Feeders

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no signup required. All answers include detailed explanations.

Requirements vary by state but typically include 4–8 years of documented electrical work experience plus a valid Journeyman license.

Advanced NEC code interpretation, load calculations, service entrance design, motor controls, generator systems, and electrical system design.

The Master exam focuses more on design, calculations, and planning rather than installation details. Load calculation and service sizing questions are weighted heavily.

Before You Start

  • 25 questions — multiple choice
  • 45 minutes to finish (timer starts when you begin)
  • Pass score is 70% — you need at least 18 correct answers
  • Full NEC 2023 explanation shown for every question after you submit

Topics in This Test

  • GFCI required in bathrooms — every receptacle, no exceptions (NEC 210.8(A)(1))
  • GFCI required in kitchens — all 125-250V receptacles, not just countertop ones (NEC 210.8(A)(6))
  • GFCI required in garages and accessory buildings at or below grade (NEC 210.8(A)(2))
  • GFCI required outdoors (NEC 210.8(A)(3))
  • GFCI required in crawl spaces at or below grade (NEC 210.8(A)(4))
  • GFCI required in unfinished basements (NEC 210.8(A)(5))
  • GFCI required within 6 ft of any sink, in any room (NEC 210.8(A)(7))
  • GFCI required for dwelling-unit dishwasher branch circuits (NEC 210.8(A)(9))
  • GFCI required within 6 ft of a bathtub or shower stall (NEC 210.8(A)(10))
  • GFCI required in laundry areas (NEC 210.8(A)(11))
  • The dwelling-unit GFCI list grew to 12 locations in recent NEC cycles (NEC 210.8(A))
  • AFCI-protected room list — kitchens, family rooms, bedrooms, and more (NEC 210.12(B))
  • Which branch circuits AFCI protection applies to (NEC 210.12(B))
  • AFCI devices must be readily accessible (NEC 210.12)
  • AFCI protection on branch circuit extensions and modifications (NEC 210.12(D))
  • Multiwire branch circuits need a simultaneous disconnecting means (NEC 210.4(B))
  • Why an open neutral on a multiwire circuit is dangerous
  • Handle ties and two-pole common-trip breakers as compliant methods (NEC 210.4(B))
  • Feeder ampacity — 125% of continuous load plus 100% of noncontinuous load (NEC 215.2(A)(1))
  • The 100%-rated assembly exception to the 125% feeder rule (NEC 215.2)
  • Worked feeder-sizing calculation combining continuous and noncontinuous loads
  • Voltage drop guidance — 3%/5% recommendation, not a hard requirement (Informational Notes to 210.19 and 215.2)
  • Scenario — an ungrounded kitchen receptacle with no GFCI protection
  • Scenario — a multiwire circuit fed by two single-pole breakers with no handle tie
  • Comparing GFCI's per-location approach to AFCI's per-room approach

Tip: GFCI protects people from shock by watching for current leaking to ground; AFCI protects property from fire by watching for the electrical signature of arcing. Keep that distinction in mind and the two location lists start to make a lot more sense.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

MASTER · NEC 2023
Master Electrician Practice Test 30 – GFCI/AFCI Requirements & Feeders Deep Dive
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

Master Electrician Practice Test 30 – GFCI/AFCI Requirements & Feeders Deep Dive — Question List

Question 1: In a dwelling unit, which receptacles in a bathroom require GFCI protection?

  • Every receptacle in the bathroom
  • Only receptacles within 3 ft of the sink
  • Only receptacles rated 30A or higher
  • None — bathrooms are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(1)

Question 2: In a dwelling-unit kitchen, which receptacles need GFCI protection under NEC 210.8(A)(6)?

  • All 125V-250V receptacles in the kitchen, not only countertop ones
  • Only receptacles serving the countertop
  • Only 125V receptacles under 20A
  • None — kitchens are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(6)

Question 3: NEC 210.8(A)(2) requires GFCI protection for receptacles in garages and accessory buildings when they are:

  • At or below grade level, in areas not intended as habitable rooms
  • Above the second floor only
  • Only in garages with a car lift installed
  • Garages are exempt from GFCI protection entirely

NEC Reference: NEC 210.8(A)(2)

Question 4: NEC 210.8(A)(3) requires GFCI protection for which dwelling-unit receptacles?

  • Outdoor receptacles
  • Only receptacles under a covered porch
  • Only receptacles more than 20 ft from the house
  • Outdoor receptacles are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(3)

Question 5: NEC 210.8(A)(4) requires GFCI protection in dwelling-unit crawl spaces when they are:

  • At or below grade level
  • Only if the crawl space is heated
  • Only if the crawl space exceeds 500 sq ft
  • Crawl spaces are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(4)

Question 6: NEC 210.8(A)(5) requires GFCI protection in which part of a dwelling-unit basement?

  • Unfinished portions not intended as habitable rooms
  • Only fully finished basements with carpet
  • Only basements with an exterior walkout door
  • Basements are exempt from GFCI protection entirely

NEC Reference: NEC 210.8(A)(5)

Question 7: NEC 210.8(A)(7) requires GFCI protection for any receptacle within what distance of a sink, regardless of which room the sink is in?

  • 6 ft from the outside edge of the sink
  • 3 ft from the outside edge of the sink
  • 10 ft from the outside edge of the sink
  • This rule applies only to kitchen sinks

NEC Reference: NEC 210.8(A)(7)

Question 8: NEC 210.8(A)(9) requires GFCI protection for a dwelling-unit dishwasher's branch circuit:

  • Whether it is cord-and-plug connected or hard-wired
  • Only if it is cord-and-plug connected
  • Only if it is hard-wired directly
  • Dishwashers are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(9)

Question 9: NEC 210.8(A)(11) requires GFCI protection for receptacles in which dwelling-unit location?

  • Laundry areas
  • Formal dining rooms
  • Home offices
  • Laundry areas are exempt from GFCI protection

NEC Reference: NEC 210.8(A)(11)

Question 10: How many distinct dwelling-unit locations does the NEC 210.8(A) GFCI list now cover?

  • 12 locations
  • 4 locations
  • 6 locations
  • 20 locations

NEC Reference: NEC 210.8(A)

Question 11: NEC 210.12(B) requires AFCI protection in which of these dwelling-unit rooms?

  • Bedrooms, family rooms, kitchens, living rooms, and similar finished spaces
  • Only detached garages
  • Only unfinished basements
  • No rooms — AFCI applies only to commercial buildings

NEC Reference: NEC 210.12(B)

Question 12: NEC 210.12(B) applies AFCI protection to which type of branch circuits?

  • 120V, single-phase, 10A, 15A, and 20A branch circuits
  • 240V, single-phase circuits only
  • Only three-phase circuits
  • Only circuits rated 30A or higher

NEC Reference: NEC 210.12(B)

Question 13: NEC 210.12 requires an AFCI device to be installed in a location that is:

  • Readily accessible
  • Permanently sealed behind drywall
  • Located only in an attic
  • There is no accessibility requirement

NEC Reference: NEC 210.12

Question 14: Under NEC 210.12(D), when an existing dwelling-unit branch circuit is extended or modified in an area covered by 210.12(B), what does the code generally require?

  • AFCI protection generally must be added to the extended or modified circuit
  • The rest of the house must also be retrofitted with AFCI protection
  • AFCI protection is never required on existing circuits under any condition
  • The circuit must be abandoned rather than extended

NEC Reference: NEC 210.12(D)

Question 15: NEC 210.4(B) requires a multiwire branch circuit to have a disconnecting means that:

  • Simultaneously disconnects all ungrounded conductors at the origin
  • Disconnects only the neutral conductor
  • Disconnects one ungrounded conductor at a time, on separate switches
  • Is not required at all for multiwire branch circuits

NEC Reference: NEC 210.4(B)

Question 16: Why is the simultaneous-disconnect rule in NEC 210.4(B) so important for multiwire branch circuits?

  • A shared neutral can stay energized from the other leg if only one hot is disconnected
  • It has nothing to do with safety, only with equipment cost
  • It only matters for circuits over 277V
  • Multiwire circuits never actually share a neutral conductor

NEC Reference: NEC 210.4(B)

Question 17: Which of these methods satisfies the NEC 210.4(B) simultaneous-disconnect requirement for a multiwire branch circuit fed by two single-pole breakers?

  • An approved handle tie identified for the purpose, linking both breaker handles
  • Leaving the two breakers completely independent with no tie
  • Labeling the panel only, with no physical linking device
  • There is no method that satisfies this rule with single-pole breakers

NEC Reference: NEC 210.4(B)

Question 18: Per NEC 215.2(A)(1), the minimum ampacity of a feeder supplying both continuous and noncontinuous loads must be at least:

  • 125% of the continuous load plus 100% of the noncontinuous load
  • 100% of the continuous load plus 125% of the noncontinuous load
  • 100% of the combined total load, with no multiplier
  • 150% of the continuous load only, ignoring noncontinuous load

NEC Reference: NEC 215.2(A)(1)

Question 19: When does NEC 215.2 permit a feeder to be sized at just 100% of the combined continuous and noncontinuous load, instead of applying the usual 125% factor?

  • When the assembly, including its overcurrent protection, is listed for 100% operation
  • Whenever the installer prefers smaller conductors
  • Only in single-family dwellings
  • This exception does not exist in the NEC

NEC Reference: NEC 215.2

Question 20: A feeder supplies a 32A continuous load and an 18A noncontinuous load, using standard (not 100%-rated) equipment. What minimum ampacity must the feeder have?

  • 58A
  • 50A
  • 40A
  • 62.5A

NEC Reference: NEC 215.2(A)(1)

Question 21: What does the NEC say about the commonly cited 3% branch-circuit / 5% total system voltage drop figures?

  • They are recommendations in Informational Notes, not enforceable requirements
  • They are hard mandatory limits enforced on every installation
  • They apply only to swimming pool circuits
  • The NEC has never mentioned any voltage drop percentage

NEC Reference: NEC Informational Notes to 210.19 and 215.2

Question 22: An inspector finds a kitchen receptacle 4 ft from the sink, on a 125V circuit, with no GFCI protection. Does this comply with the NEC?

  • No — it is within 6 ft of the sink and in a kitchen, so GFCI protection is required
  • Yes — GFCI is only required within 3 ft of a kitchen sink
  • Yes — kitchens are fully exempt from GFCI protection
  • It depends only on the receptacle's amperage rating

NEC Reference: NEC 210.8(A)(6)-(7)

Question 23: A multiwire branch circuit originates from two single-pole breakers in a panel, with no handle tie and no common-trip mechanism between them. Does this comply with NEC 210.4(B)?

  • No — a handle tie or common-trip mechanism is required for simultaneous disconnect
  • Yes — two independent single-pole breakers always satisfy 210.4(B)
  • Yes — the rule only applies to circuits over 240V
  • It depends only on the panel manufacturer

NEC Reference: NEC 210.4(B)

Question 24: How do the GFCI list (210.8(A)) and the AFCI list (210.12(B)) generally differ in the way they identify covered locations?

  • GFCI targets damp/wet shock-risk spots; AFCI targets whole finished living-space rooms
  • The two lists are actually identical, room for room
  • GFCI applies only to commercial buildings and AFCI only to dwellings
  • Neither list has anything to do with location at all

NEC Reference: NEC 210.8(A), 210.12(B)

Question 25: Fundamentally, what is the core difference between what GFCI protection and AFCI protection are each designed to prevent?

  • GFCI prevents shock from ground-fault current; AFCI prevents fire from arcing faults
  • GFCI and AFCI are two names for the exact same protection function
  • GFCI prevents fire; AFCI prevents shock — the reverse of their actual functions
  • Neither device is designed to prevent any specific hazard

NEC Reference: NEC Article 100 (Definitions)

Key NEC References for This Test

ArticleWhat It Covers
Art. 220Load Calculations — optional and standard methods for multifamily
Art. 230Services — service design, sizing, multiple disconnects
Art. 430Motors — complete branch circuit design (conductor + OCPD + overload + disconnect)
Art. 445Generators — standby systems, transfer switches
Art. 450Transformers — sizing, primary/secondary OCPD, installation
Art. 706Energy Storage Systems — battery/solar storage (major NEC 2026 expansion)
Study Tip: Practice transformer kVA calculations daily. Know the formula: I = kVA × 1000 ÷ (V × 1.732) for three-phase. This comes up on almost every master exam.
EXAM CARD MASTER
Questions25
Time limit45 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)