EPA 608 NEC 2023

EPA 608 Type II & III Practice Test 9

This test covers the venting ban and substantial leak repair rules under Clean Air Act Section 608, including the 15% comfort cooling and 35% process refrigeration thresholds, applied to both Type II and Type III equipment.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Type II & III Exam Tip: Comfort cooling uses a 15% per year substantial leak threshold; commercial and industrial process refrigeration uses 35%. Both apply to appliances with 50 lbs or more of charge.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type II & III Practice Test 9
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type II & III Practice Test 9 — Question List

Question 1: Venting refrigerant to the atmosphere on purpose has been illegal for HFCs since what date?

  • November 15, 1995
  • July 1, 1992
  • January 1, 2000
  • November 15, 1993

Question 2: Venting refrigerant to the atmosphere on purpose has been illegal for CFCs and HCFCs since what date?

  • November 15, 1995
  • July 1, 1992
  • November 15, 1993
  • January 1, 1990

Question 3: True or False: The venting ban applies equally to Type II and Type III equipment, with no exemption for chillers just because they run at a vacuum.

  • True
  • False
  • True, but only for large chillers
  • False, chillers are exempt from the venting ban

Question 4: What is the maximum possible fine, per day, per violation, for illegally venting refrigerant?

  • Up to $4,453
  • Up to $445,390
  • There is no maximum fine
  • Up to $44,539

Question 5: A commercial process refrigeration system with a 60 lb charge loses refrigerant at 20% per year. Which threshold applies to this system, and does 20% exceed it?

  • 15% threshold applies; 20% exceeds it
  • 35% threshold applies; 20% exceeds it
  • 35% threshold applies; 20% does not exceed it
  • 15% threshold applies; 20% does not exceed it

Question 6: Which type of system uses the 15% per year substantial leak threshold?

  • Commercial and industrial process refrigeration
  • Both use 15%
  • Comfort cooling, including most large chillers used for building air conditioning
  • Neither uses a percentage threshold

Question 7: Which type of system uses the 35% per year substantial leak threshold?

  • Comfort cooling only
  • Both use 35%
  • Commercial and industrial process refrigeration
  • Residential split systems only

Question 8: The substantial leak rate thresholds apply to appliances with how much refrigerant charge?

  • 5 lbs or more
  • 500 lbs or more
  • Any charge, no minimum
  • 50 lbs or more

Question 9: Once a substantial leak is discovered on a covered appliance, how many days does the owner generally have to repair it, or retrofit/retire the unit?

  • 7 days
  • 30 days
  • 15 days
  • 90 days

Question 10: A hospital's large centrifugal chiller, used for comfort cooling with a 300 lb charge, is found to be losing refrigerant at 18% per year. Does this qualify as a substantial leak?

  • Yes, 18% exceeds the 15% comfort cooling threshold that applies here
  • No, chillers are exempt from substantial leak rules
  • No, because only Type II equipment has substantial leak thresholds
  • Yes, but only because the charge is over 500 lbs

Question 11: True or False: Illegally venting refrigerant is only a violation for Type II equipment, not Type III.

  • True
  • False
  • True, unless the chiller is under warranty
  • False, only Type III has a venting ban

Question 12: Which law establishes the venting ban and substantial leak repair rules discussed in this test?

  • OSHA General Duty Clause
  • Clean Air Act Section 608
  • The AIM Act
  • The Montreal Protocol directly

Question 13: A technician finishes a repair on a rooftop unit and has some leftover refrigerant that cannot be reused. What must the technician do with it?

  • Vent it to the atmosphere since it is a small amount
  • Pour it down a drain
  • Leave it in the recovery cylinder indefinitely with no further action required
  • Recover and properly manage or dispose of it; venting is illegal regardless of amount

Question 14: A technician discovers a substantial leak on a 100 lb charge commercial process refrigeration system on March 1. By what date should the repair generally be completed?

  • March 8
  • March 31
  • March 16
  • April 30

Question 15: True or False: An owner can choose to retrofit or retire an appliance instead of repairing it, as an alternative to fixing a substantial leak.

  • False
  • True
  • True, but only for Type II
  • False, repair is the only option

Question 16: Which of these appliances would be subject to substantial leak rate rules?

  • A 20 lb residential split system
  • Neither, since both are under 50 lbs
  • Both, regardless of charge size
  • A 55 lb commercial refrigeration rack

Question 17: What is the general term for illegally releasing refrigerant into the atmosphere on purpose?

  • Venting
  • Recovery
  • Evacuation
  • Purging

Question 18: A large low-pressure chiller used for comfort cooling loses 12% of its charge over a year. Does this meet the substantial leak threshold?

  • Yes, since any leak on a chiller is automatically substantial
  • Yes, because chillers use a lower 10% threshold
  • No, 12% is below the 15% comfort cooling threshold
  • No, because chillers are exempt from leak rate rules

Question 19: A technician incorrectly believes that because a Type III chiller runs at a vacuum, it cannot be fined for venting refrigerant, since there is nothing to vent out. Why is this wrong?

  • It is correct; chillers cannot vent refrigerant
  • Chillers are exempt from Clean Air Act Section 608 entirely
  • The venting ban applies to intentional releases of refrigerant regardless of operating pressure; a chiller can still be serviced improperly in ways that release refrigerant, and the ban applies with no vacuum exemption
  • Only leaks under 50 lbs are exempt

Question 20: True or False: The substantial leak threshold percentages, 15% and 35%, are based on how much refrigerant is lost per year, relative to the system's total charge.

  • True
  • False
  • True, but measured monthly
  • False, they are fixed pound amounts

Question 21: Which best describes the difference between the 15% and 35% substantial leak thresholds?

  • 15% applies to Type III; 35% applies to Type II
  • 15% applies to small systems; 35% applies to large systems
  • There is no real difference; both are the same rule
  • 15% applies to comfort cooling; 35% applies to commercial/industrial process refrigeration

Question 22: Since what year has venting HFC refrigerants like R-410A been illegal?

  • 1990
  • 1992
  • 2000
  • 1995

Question 23: A 250 lb charge comfort cooling chiller loses refrigerant at exactly 15% per year. Does this meet the substantial leak threshold?

  • Yes, reaching the 15% comfort cooling threshold meets the definition
  • No, it must exceed 15%, not just meet it
  • No, chillers use a different threshold entirely
  • Yes, but only because the charge is over 200 lbs

Question 24: True or False: A technician who vents refrigerant to avoid the cost and time of proper recovery could face fines up to $44,539 per day, per violation.

  • True
  • False
  • True, but only for repeat offenders
  • False, fines only apply to companies, not individuals

Question 25: Which statement best summarizes the venting ban and substantial leak rules as they apply to Type II and Type III equipment?

  • Only Type II equipment is covered by these rules
  • Only appliances under 50 lbs are covered
  • Both Type II and Type III equipment are covered equally; venting is illegal for both, and substantial leak thresholds, 15% comfort cooling, 35% process, apply based on application, with repair generally required within 30 days
  • Chillers are exempt because they run at a vacuum
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)