EPA 608 NEC 2023

EPA 608 Type I Practice Test 8

This test focuses on the difference between recovery, recycling, and reclaiming refrigerant, using small-appliance scenarios. It covers which process is required for disposal, which allows reuse on the same job, and which is the only legal path to resell refrigerant to a new owner.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Type I Exam Tip: Recovery just removes and stores. Recycling cleans it on-site for the same owner. Reclaiming purifies it to AHRI Standard 700 at a certified facility, the only process that allows resale to a new owner.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type I Practice Test 8
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type I Practice Test 8 — Question List

Question 1: What does "recovery" mean when talking about refrigerant?

  • Removing refrigerant from a system and storing it
  • Selling refrigerant to a new customer
  • Purifying refrigerant to a certified purity standard
  • Venting refrigerant safely into the outdoors

Question 2: What does "recycling" mean when talking about refrigerant?

  • Cleaning refrigerant on-site for reuse, still by the same owner or on the same job
  • Purifying refrigerant to AHRI Standard 700 at a certified facility
  • Venting refrigerant into the atmosphere
  • Selling refrigerant to any new customer

Question 3: What does "reclaiming" mean when talking about refrigerant?

  • Simply storing refrigerant in a cylinder
  • Venting refrigerant to reduce pressure
  • Processing refrigerant to AHRI Standard 700 purity at a certified facility
  • Reusing refrigerant without any processing at all

Question 4: A technician removes refrigerant from a broken vending machine and stores it in a cylinder, with no cleaning or processing. What is this called?

  • Reclaiming
  • Recycling
  • Reselling
  • Recovery

Question 5: A technician removes refrigerant from a refrigerator, filters it on-site, and puts it back into the same unit after a repair. What is this process called?

  • Recovery
  • Recycling
  • Reclaiming
  • Reselling

Question 6: Refrigerant recovered from several appliances is sent to a certified facility, where it is purified to AHRI Standard 700 so it can be sold to a new customer. What is this process called?

  • Recovery
  • Recycling
  • Reclaiming
  • Venting

Question 7: True or False: Refrigerant that has only been recovered, with no further processing, can legally be sold to a new owner.

  • True, recovery alone is enough for resale
  • True, as long as the cylinder is labeled
  • True, if the refrigerant is R-134a
  • False, only reclaimed refrigerant may legally be resold to a new owner

Question 8: True or False: Refrigerant that has been recycled on-site can be sold to a brand-new customer who was not part of the original job.

  • True, recycled refrigerant can always be resold
  • True, as long as it passes a visual inspection
  • True, if it is recycled twice
  • False, recycled refrigerant is limited to the same owner or job

Question 9: Which of the three processes, recovery, recycling, or reclaiming, requires a certified facility?

  • Recovery
  • Recycling
  • Reclaiming
  • None of them require a certified facility

Question 10: Before a small appliance can be scrapped, which of the three processes is the minimum legally required step?

  • Recovery
  • Recycling
  • Reclaiming
  • All three are required before disposal

Question 11: A technician recovers refrigerant from a broken refrigerator, filters it, and puts it into a replacement refrigerator for the same customer, on the same job. What best describes this process?

  • Reclaiming, because the refrigerant is reused
  • Recovery, because refrigerant was removed from a system
  • Recycling, because it was cleaned on-site for the same owner
  • Venting, because refrigerant left the original system

Question 12: Why can refrigerant that has only been recovered not simply be sold as-is to a new owner?

  • It has not been purified or certified to a resale purity standard, which only reclaiming provides
  • Recovered refrigerant is always contaminated with air only
  • It is against the law to store refrigerant in any cylinder
  • Recovered refrigerant loses its chemical identity

Question 13: Of the three processes, which one is the simplest, involving no cleaning or purity testing at all?

  • Recovery
  • Recycling
  • Reclaiming
  • They are all equally complex

Question 14: What is the maximum refrigerant charge for a hermetically sealed system to qualify as Type I?

  • 10 pounds
  • 5 pounds or less
  • 20 pounds
  • 50 pounds

Question 15: What passing score applies to the open-book Type I exam?

  • 70%
  • 60%
  • 84%
  • 50%

Question 16: What recovery efficiency must system-dependent recovery reach when the compressor is running?

  • 70%
  • 80%
  • 100%
  • 90%

Question 17: What recovery efficiency must self-contained recovery equipment reach when the compressor is dead?

  • 90%
  • 80%
  • 50%
  • 65%

Question 18: Which small-appliance refrigerant is flammable and requires spark-free recovery tools and equipment?

  • R-134a
  • R-600a
  • R-12
  • R-22

Question 19: True or False: A small appliance can be disposed of without any recovery step, as long as recycling and reclaiming are not needed.

  • True, recovery is optional if recycling is not needed
  • True, only reclaiming is legally required before disposal
  • True, disposal has no refrigerant-related requirements
  • False, recovery is always required before disposal

Question 20: Why must refrigerant be recovered before a technician brazes a sealed line?

  • Leftover refrigerant can break down into toxic byproducts, like phosgene gas
  • It has no effect on safety
  • It only matters for reclaimed refrigerant
  • It prevents the joint from cooling too fast

Question 21: Who is legally allowed to purchase Class I and Class II refrigerants?

  • Only certified technicians
  • Any adult customer
  • Only appliance recyclers
  • Only certified facility managers

Question 22: What protective gear should a technician wear while recovering refrigerant, regardless of whether it will later be recycled or reclaimed?

  • No protection is needed
  • Eye and skin protection
  • A hard hat only
  • Ear plugs only

Question 23: Since what date has it been illegal to knowingly vent HFC refrigerants, instead of recovering them?

  • July 1, 1992
  • November 15, 1995
  • January 1, 1990
  • November 15, 1993

Question 24: A technician holds only Type I certification. Does this allow the technician to recover refrigerant from a central split-system air conditioner?

  • Yes, Type I covers all recovery work
  • No, Type I only covers small-appliance work
  • Yes, as long as the refrigerant is later reclaimed
  • Yes, since recovery has no certification requirement

Question 25: Who needs Type I certification to legally recover refrigerant from a small appliance?

  • Anyone who services, maintains, repairs, or disposes of hermetically sealed small appliances
  • Only technicians who work at certified reclaiming facilities
  • Only technicians who never recycle refrigerant
  • No one, small appliance recovery is unregulated
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)