EPA 608 NEC 2023

EPA 608 Type I Practice Test 6

This test focuses on brazing and soldering safety on hermetically sealed systems: why refrigerant must be recovered and evacuated before applying a torch, the risk of toxic byproducts like phosgene gas, and the added precautions needed on flammable-refrigerant systems.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Type I Exam Tip: Never braze a line with refrigerant still inside. Heat from an open flame can break refrigerant down into toxic byproducts like phosgene gas. On flammable-refrigerant systems, confirm the system is fully evacuated before applying the torch.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type I Practice Test 6
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type I Practice Test 6 — Question List

Question 1: What must happen before a technician brazes a line on a hermetically sealed small appliance?

  • The refrigerant must be recovered and the system evacuated
  • The appliance must be repainted first
  • The compressor must be running
  • Nothing extra is required

Question 2: What toxic gas can form if refrigerant left in a line is exposed to an open flame during brazing?

  • Phosgene gas
  • Helium gas
  • Nitrogen gas
  • Oxygen gas

Question 3: Why does refrigerant left in a sealed line pose a toxic gas risk during brazing?

  • The refrigerant expands and bursts the line
  • The refrigerant simply evaporates with no risk
  • The heat of the open flame can break the refrigerant down into toxic byproducts
  • The refrigerant cools the flame and prevents brazing

Question 4: On a system using flammable R-600a refrigerant, what extra step must be confirmed before brazing begins?

  • That the appliance is painted a warning color
  • That the appliance is still plugged in
  • That the refrigerant is dyed red
  • That the system is fully evacuated or purged

Question 5: A technician skips recovery and starts brazing a line that still has refrigerant in it. What is the main danger?

  • Exposure to toxic byproducts, like phosgene gas, released by the heated refrigerant
  • The joint will look less shiny
  • The appliance warranty is voided
  • The brazing rod will not stick to the metal

Question 6: True or False: If a gauge reads zero pressure on a sealed system, that alone means it is safe to braze without doing a proper recovery and evacuation.

  • True, zero pressure always means it is safe to braze
  • True, as long as the gauge is accurate
  • True, because pressure and refrigerant content are the same thing
  • False, a zero reading does not replace a proper recovery and evacuation

Question 7: While brazing a line, a technician notices an unusual sharp odor. What should the technician do?

  • Keep brazing until the joint is finished
  • Ignore it, odors are normal during brazing
  • Stop immediately, move away from the fumes, and ventilate the area
  • Add more flux to cover the smell

Question 8: What basic precautions should a technician take while brazing, beyond recovering the refrigerant?

  • Wear eye protection and work in a well-ventilated area
  • No precautions are needed once refrigerant is recovered
  • Only ear protection is required
  • Brazing should always be done in a sealed, unventilated closet

Question 9: True or False: An open flame from a torch can break refrigerant down into a toxic gas.

  • True, an open flame can break refrigerant down into toxic gas
  • False, refrigerant is unaffected by heat
  • False, only cold temperatures affect refrigerant
  • True, but only for R-134a

Question 10: Which type of small-appliance refrigerant system needs extra confirmation of full evacuation before brazing, because of ignition risk?

  • A system using non-flammable R-134a refrigerant
  • A system using flammable R-600a refrigerant
  • Any system built after 2015
  • Any system with a plastic housing

Question 11: A technician has met the required recovery efficiency (90% or 80%, depending on the method used) on a small appliance. Is it automatically safe to braze the lines at this point?

  • Yes, meeting the recovery efficiency requirement always means it is safe to braze
  • Not necessarily. The system should also be confirmed fully evacuated before brazing
  • No, brazing is never allowed on any recovered system
  • Yes, but only if the refrigerant was R-12

Question 12: Besides the risk of toxic gas, what other danger does brazing a live flammable-refrigerant system create?

  • The metal will become permanently magnetized
  • A fire or ignition risk from the flammable refrigerant
  • The compressor will run backward
  • The refrigerant will change color permanently

Question 13: What is good practice right before applying a torch to a recovered sealed system?

  • Ventilate the area and remove ignition sources nearby
  • Close all windows and doors tightly
  • Turn the appliance back on
  • Add extra refrigerant before starting

Question 14: What refrigerant charge limit applies to Type I small appliances?

  • 10 pounds
  • 5 pounds or less
  • 20 pounds
  • 2 pounds exactly, no more or less

Question 15: What passing score applies to the open-book Type I exam?

  • 70%
  • 60%
  • 84%
  • 50%

Question 16: What recovery efficiency is required using system-dependent recovery on a working compressor?

  • 70%
  • 80%
  • 100%
  • 90%

Question 17: What recovery efficiency is required using self-contained recovery equipment on a dead compressor?

  • 90%
  • 80%
  • 50%
  • 65%

Question 18: Which refrigerant is non-flammable and common in older household refrigerators?

  • R-600a
  • R-134a
  • Propane
  • Ethane

Question 19: True or False: A small appliance with only 1 pound of refrigerant is exempt from the recovery-before-disposal rule because the charge is so small.

  • True, charges under 2 pounds are exempt
  • True, only appliances over 3 pounds require recovery
  • False, there is no small-charge exception to the recovery rule
  • True, but only for R-134a systems

Question 20: Who is legally allowed to buy Class I and Class II refrigerants used in small appliances?

  • Only certified technicians
  • Any adult with cash
  • Only welding supply stores
  • Only appliance manufacturers

Question 21: What is the difference between recycling and reclaiming refrigerant?

  • They are exactly the same process
  • Recycling cleans refrigerant on-site for reuse by the same owner, while reclaiming allows resale after processing at a certified facility
  • Recycling requires a certified facility and reclaiming does not
  • Reclaiming is always illegal

Question 22: What protective gear should a technician wear any time refrigerant is being recovered, before any brazing begins?

  • No protection is needed
  • Eye and skin protection
  • A raincoat only
  • Steel-toe boots only

Question 23: Since what date has it been illegal to knowingly vent HFC refrigerants into the atmosphere?

  • July 1, 1992
  • November 15, 1995
  • January 1, 1990
  • November 15, 1993

Question 24: A technician with only a Type I certification is asked to braze a line on a central split-system air conditioner. Is this technician certified to do this job?

  • Yes, Type I covers all brazing work
  • Yes, as long as the refrigerant charge is under 5 pounds
  • Yes, brazing has no certification requirement
  • No, Type I only covers small-appliance work

Question 25: Who is required to hold Type I certification?

  • Anyone who services, maintains, repairs, or disposes of small, hermetically sealed appliances that could release refrigerant
  • Only technicians who never touch a torch
  • Only appliance store clerks
  • Only technicians working on central chillers
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)