NATE_AC_SERVICE NEC 2023

NATE AC Service Practice Test 4

This test covers compressor types, motor types, and starting components used in residential AC systems. You will practice identifying scroll, reciprocating, and rotary compressors, plus capacitor and motor basics.

TOPICS COVERED
NATE AC Service

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 30 min for 30 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no signup required. Every question includes a full explanation of the correct answer.

Two: the NATE Core exam plus at least one specialty exam (for example AC Service, Heat Pump Service, or Air Distribution Service). You can take them on the same day or separately.

The Core exam has 50 questions and each installation or service specialty exam has 100 questions. You need 70% on each to pass — 35 of 50 on Core and 70 of 100 on a specialty. Check natex.org for the current format before you book.

NATE certification lasts two years. To renew, you submit 16 hours of continuing education or retake the specialty exam before your certification expires.

No. These are independent practice tests written to match the published NATE exam topics. They are not official NATE exam questions.

Exam Tip: Capacitors hold a dangerous charge even after power is off. Always discharge one safely with an insulated tool before touching its terminals.

30
Questions
30 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NATE_AC_SERVICE · NEC 2023
NATE AC Service Practice Test 4
Q1 / 30
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time
My Missed Questions

Electrician Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NATE AC Service Practice Test 4 — Question List

Question 1: Which compressor type is most commonly used in residential AC systems today?

  • Scroll compressor
  • Screw compressor
  • Centrifugal compressor
  • Axial compressor

NEC Reference: NULL

Question 2: How does a reciprocating compressor compress refrigerant?

  • With pistons moving up and down inside cylinders
  • With two interleaving spiral scrolls
  • With a rotating impeller at high speed
  • With a magnetic field only, no moving parts

NEC Reference: NULL

Question 3: What is a general feature of a rotary compressor?

  • It floods the evaporator with liquid refrigerant by design
  • It uses a rotating mechanism inside a cylinder to compress refrigerant
  • It only operates on three-phase power
  • It has no compression chamber at all

NEC Reference: NULL

Question 4: What does PSC stand for in an AC motor, and where is it commonly used?

  • Permanent Split Capacitor, used on condenser fan and blower motors
  • Positive Series Circuit, used only on compressors
  • Pressure Sensing Control, used on pressure switches
  • Power Supply Converter, used on control boards

NEC Reference: NULL

Question 5: What does a run capacitor do on a PSC motor?

  • It disconnects the motor completely once it reaches full speed
  • It only assists for the first half-second, then disconnects
  • It stays in the circuit while running, helping create the needed phase shift
  • It controls the thermostat setpoint

NEC Reference: NULL

Question 6: Why do some compressors use a start capacitor in addition to a run capacitor (CSIR or CSCR configurations)?

  • To provide extra starting torque needed under load
  • To reduce voltage to the compressor permanently
  • To slow the compressor down during startup
  • To replace the need for a contactor

NEC Reference: NULL

Question 7: True or False: A start capacitor typically stays in the circuit only briefly during start-up and then is switched out, usually by a relay.

  • False, start capacitors always stay in the circuit continuously
  • False, start capacitors are never switched out
  • True
  • False, only run capacitors are switched out

NEC Reference: NULL

Question 8: What is a typical acceptable tolerance range for a run capacitor's rated microfarad (MFD) value?

  • Roughly plus or minus 6 percent
  • Roughly plus or minus 50 percent
  • Exactly 0 percent, no tolerance allowed
  • Roughly plus or minus 25 percent

NEC Reference: NULL

Question 9: Why must a capacitor be safely discharged before a technician handles its terminals, even after the power is turned off?

  • A capacitor can retain a dangerous charge even with power off
  • Capacitors are always completely safe once power is off
  • It is only a concern for start capacitors, not run capacitors
  • It is only a concern in commercial equipment

NEC Reference: NULL

Question 10: What is a "dual run capacitor" commonly used for in residential condensing units?

  • It replaces the contactor entirely
  • It is only used for indoor blower motors
  • It provides run capacitor function for both compressor and condenser fan motor
  • It stores backup power for the thermostat

NEC Reference: NULL

Question 11: A compressor hums but does not start, and then trips its overload. What is a common cause to check first?

  • A dirty air filter
  • A programmed thermostat schedule
  • A weak or failed run capacitor
  • Low indoor humidity

NEC Reference: NULL

Question 12: What is the difference between SEER and EER as efficiency ratings for AC equipment?

  • SEER and EER measure the exact same thing with different units
  • EER measures seasonal efficiency; SEER measures one rated condition
  • SEER measures seasonal efficiency; EER measures one rated condition
  • Neither rating relates to compressor efficiency

NEC Reference: NULL

Question 13: True or False: A higher SEER rating means a more efficient air conditioning system.

  • False, a lower SEER is always more efficient
  • False, SEER has no relation to efficiency
  • False, SEER only applies to heating equipment
  • True

NEC Reference: NULL

Question 14: What is the function of the contactor in an outdoor condensing unit?

  • It measures refrigerant pressure
  • It stores refrigerant during defrost
  • It regulates indoor humidity
  • It is a switch connecting line voltage power to the compressor and fan

NEC Reference: NULL

Question 15: How are low-pressure and high-pressure safety switches typically wired in relation to the contactor coil circuit?

  • In parallel, closing to start the compressor on high pressure
  • In series, but only active during heating mode
  • They are not connected to the contactor circuit at all
  • In series, as normally closed switches that open on unsafe pressure

NEC Reference: NULL

Question 16: In standard thermostat wiring conventions, what does the "Y" terminal typically control?

  • The 24V hot power supply
  • The cooling call that energizes the contactor
  • The indoor blower fan only, with no connection to cooling
  • The common wire for the transformer

NEC Reference: NULL

Question 17: A compressor starts normally but its running amp draw is well above the nameplate rated load amps (RLA). What should the technician check?

  • Refrigerant charge, airflow, and head pressure
  • The thermostat display brightness
  • The color of the refrigerant lines
  • The indoor humidity sensor only

NEC Reference: NULL

Question 18: True or False: Scroll compressors are generally known for quieter, smoother operation compared to older reciprocating designs.

  • False, reciprocating compressors are always quieter
  • False, noise level has nothing to do with compressor type
  • False, scroll compressors are the loudest type available
  • True

NEC Reference: NULL

Question 19: What does a potential relay do in a CSIR or CSCR compressor starting circuit?

  • It controls indoor blower speed only
  • It senses motor speed and switches the start capacitor out once near full speed
  • It measures refrigerant subcooling
  • It replaces the need for a run capacitor

NEC Reference: NULL

Question 20: What is a "hard start kit" used for on a PSC compressor?

  • It reduces the compressor's running voltage permanently
  • It replaces the contactor with a solid-state relay
  • It converts a three-phase compressor to single-phase
  • It adds a start capacitor and relay for extra starting torque

NEC Reference: NULL

Question 21: A technician notices a run capacitor with a bulging or domed top. What does this usually indicate?

  • The capacitor is operating at peak performance
  • The capacitor is failing and should be replaced
  • The capacitor needs more refrigerant charge
  • The capacitor is simply the wrong color

NEC Reference: NULL

Question 22: Between PSC and CSCR (capacitor-start, capacitor-run) compressor motors, which one generally provides higher starting torque?

  • PSC, because it has no start capacitor to slow it down
  • They are always identical in starting torque
  • CSCR, because it uses both a start and run capacitor together at start-up
  • Neither type has any starting torque difference by design

NEC Reference: NULL

Question 23: True or False: A run capacitor that has weakened and reads well below its rated microfarad value can cause a motor to overheat, run slower, or fail to start.

  • False, capacitor value has no effect on motor performance
  • False, only start capacitors can cause these symptoms
  • False, a weak capacitor only affects noise, never performance
  • True

NEC Reference: NULL

Question 24: A compressor has an internal overload protector. What is its purpose?

  • It senses excessive motor temperature or current and opens the circuit to protect the compressor
  • It increases refrigerant pressure to boost capacity
  • It controls the indoor thermostat display
  • It is only found on condenser fan motors, never compressors

NEC Reference: NULL

Question 25: Where are rotary compressors most commonly found?

  • Only in large commercial chillers
  • In smaller equipment such as window units and mini-splits
  • Only in industrial ammonia refrigeration systems
  • They are no longer used in any equipment

NEC Reference: NULL

Question 26: What is the correct order of steps before testing a run capacitor with a multimeter?

  • Test it first, then turn off power afterward
  • Turn off power, discharge the capacitor, then test it
  • Discharge it while power is still on
  • Skip discharging since testing is quick

NEC Reference: NULL

Question 27: True or False: A technician can sometimes get a hint about compressor type from the nameplate or documentation, since visual identification from the outside alone is not always reliable.

  • False, all compressor shells look completely different from each other
  • False, the nameplate never lists compressor type
  • False, sound alone is always a perfectly reliable indicator
  • True

NEC Reference: NULL

Question 28: A technician finds a dirty condenser coil causing high head pressure, along with a compressor drawing high amps. What is the most likely relationship between these two findings?

  • The two findings are unrelated coincidences
  • The compressor amp draw is causing the head pressure to rise
  • High head pressure from restricted airflow is making the compressor work harder
  • A dirty condenser coil always lowers compressor amp draw

NEC Reference: NULL

Question 29: True or False: A three-phase compressor motor generally does not need a start or run capacitor to start and run, unlike a typical single-phase residential compressor.

  • False, three-phase motors need even more capacitors than single-phase
  • False, three-phase power does not exist in HVAC equipment
  • False, capacitors are required on all compressor types equally
  • True

NEC Reference: NULL

Question 30: Which statement correctly summarizes residential AC compressor and capacitor basics?

  • Reciprocating compressors are now the most common type in residential systems
  • Scroll is most common today, PSC uses only a run capacitor, and capacitors must be safely discharged
  • Capacitors never hold a charge once power is off
  • Start capacitors are meant to stay in the circuit permanently

NEC Reference: NULL

EXAM CARD NATE_AC_SERVICE
Questions30
Time limit30 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)