EPA 608 NEC 2023

EPA 608 Type 1 Exam Practice Test 4

Free EPA 608 Type I Exam Practice Test 4. 25 questions on nitrogen as a flushing agent, high-side recovery with operating compressor, passive device recovery vessels, non-condensables in recovery machines, mixed refrigerant reclamation, refrigerant mixing rules, small appliance leak repair obligations, 90% recovery efficiency, sale restrictions on CFCs and HCFCs, technician responsibilities, Montreal Protocol, CFC phase-out date, DOT recovery cylinder types and fill limits, cylinder color coding, hydrostatic testing, AHRI 700 reclamation standard, recycled vs reclaimed refrigerant, R-22 production phase-out, Section 608 vs Section 609, non-condensable purging, ozone depletion and UV radiation, refrigerant purchase restrictions, nitrogen for leak testing, and refrigerant oil compatibility.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 45 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Key facts for this test: Nitrogen is used to flush debris from refrigerant circuits (not oxygen — explosion risk). System-dependent (passive) recovery captures refrigerant in a non-pressurized vessel; self-contained (active) recovery uses a pressurized DOT cylinder. Recovery cylinders must be DOT 4BA or 4BW, painted gray with a yellow top, and must not be filled beyond 80% of capacity. They require a hydrostatic test every 5 years.

25
Questions
45 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type 1 Exam Practice Test 4
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type 1 Exam Practice Test 4 — Question List

Question 1: Which of the following is used to flush debris out of the system?

  • Nitrogen
  • Oxygen
  • Refrigerant
  • Hydrogen

Question 2: If system dependent recovery process is used to recovery the refrigerant from small appliance with operating compressor, the refrigerant can recovery from ………………. of the system

  • High side
  • Low side
  • Liquid side
  • Discharge side

Question 3: A system dependent recovery machines captures the refrigerant in …………… recovery tank

  • Pressurized
  • Non pressurized

Question 4: The self contained recovery machine tank should not contain excessive …………………….

  • Non condensables
  • Pressure
  • Gas

Question 5: What a reclamation facility does if it receives a tank of mixed refrigerant?

  • They may refuse to process the refrigerant
  • They may agree to destroy the refrigerant
  • They may charge a substantial fee for destroying
  • All other options are correct

Question 6: Which of the following should not be done during recovery?

  • Do not mix the refrigerants in recovery tank
  • Do not recover the refrigerant from the liquid line
  • Do not recovery when the refrigerant pressure is high
  • Do not purge the system with nitrogen during recovery

Question 7: The refrigerant leaks from small appliances need not be repaired at any case.

  • True
  • False

Question 8: The recovery equipment manufactured after November 1993 must be able to remove ……………….. of refrigerant from the refrigeration system with compressor operating.

  • 90 %
  • 80 %
  • 85 %
  • 60 %

Question 9: The sale of CFC’s and HCFC’s is restricted to ……………….

  • Certified technicians
  • EPA certified agencies
  • Authorized owners
  • Senior technician

Question 10: It is the responsibility of ………………..  any future changes after the technician becomes certified.

  • EPA authority to communicate
  • Technician to comply with
  • Refrigeration system owner to comply with

Question 11: What is the Montreal Protocol, and what was its main purpose?

  • A US law that required all refrigerants to be replaced with nitrogen
  • An international agreement (1987) to phase out ozone-depleting substances worldwide
  • An EPA rule that set the maximum refrigerant charge allowed in small appliances
  • A Canadian standard for recovery equipment performance testing

Question 12: In the United States, the production and import of CFC refrigerants (such as R-11 and R-12) was completely banned after what date?

  • December 31, 1993
  • December 31, 1995
  • January 1, 2000
  • January 1, 1990

Question 13: What two types of DOT-approved cylinders are authorized for use as refrigerant recovery cylinders?

  • DOT 39 and DOT 4A
  • DOT 4BA and DOT 4BW
  • DOT 2A and DOT 2AL
  • DOT 4E and DOT 4B

Question 14: A recovery cylinder must not be filled beyond _______ of its rated gross water capacity (by weight).

  • 90%
  • 80%
  • 100% — cylinders are rated for full capacity
  • 70%

Question 15: What are the standard color markings for a refrigerant recovery cylinder?

  • Blue body with a green top
  • Gray body with a yellow top
  • Yellow body with a gray top
  • Red body with a white top

Question 16: How often must a DOT-approved refrigerant recovery cylinder be hydrostatically tested?

  • Every year
  • Every 5 years
  • Every 10 years
  • Every 3 years

Question 17: What standard must reclaimed refrigerant meet before it can be sold to a new owner (used in a different system)?

  • ARI 740 — performance testing standard
  • AHRI 700 — purity standard for reclaimed refrigerant
  • ASHRAE 34 — refrigerant safety classification
  • DOT 4BA — cylinder specification standard

Question 18: A technician recovers refrigerant from a customer's appliance and cleans it on-site using a recycling machine. Can this refrigerant be sold or transferred to a different customer?

  • Yes — recycled refrigerant is the same as new refrigerant and can be sold to anyone
  • No — recycled refrigerant may only be returned to the same owner and same type of equipment
  • Yes — as long as the technician tests it and it passes a moisture test
  • Yes — recycled refrigerant can be sold to any certified technician

Question 19: Under the Clean Air Act phase-out rules, the production and import of R-22 (HCFC-22) was completely banned in the United States after what date?

  • December 31, 1995
  • January 1, 2020
  • January 1, 2010
  • January 1, 2030

Question 20: A technician wants to service the air conditioning system in a customer's car. Which section of the Clean Air Act covers motor vehicle air conditioning (MVAC) systems?

  • Section 608 — it covers all refrigerant-containing equipment
  • Section 609 — which specifically covers motor vehicle air conditioning systems
  • Section 612 — which covers automotive systems
  • Car A/C is not regulated by the Clean Air Act

Question 21: A recovery cylinder contains non-condensable gases (such as air or nitrogen) that are mixing with the recovered refrigerant. Where do non-condensables collect in the cylinder, and how should they be removed?

  • At the bottom of the cylinder; drain them through the liquid port
  • At the top of the cylinder; purge them carefully from the vapor port
  • Non-condensables mix evenly throughout the cylinder and cannot be removed
  • At the top; attach a vacuum pump to remove them

Question 22: What are the main health effects on humans caused by increased ultraviolet (UV) radiation reaching Earth as a result of ozone layer depletion?

  • Increased risk of respiratory illness and asthma
  • Increased risk of skin cancer and eye cataracts
  • Increased risk of heart disease and high blood pressure
  • UV radiation has no direct health effects on humans

Question 23: Under EPA Section 608 rules, who is allowed to purchase CFC and HCFC refrigerants in containers larger than 2 pounds?

  • Anyone — refrigerant can be purchased by any member of the public
  • Only EPA-certified technicians (containers larger than 2 pounds)
  • Only engineers licensed by the state
  • Only suppliers who are licensed by the EPA

Question 24: After pressure-testing a refrigerant circuit with nitrogen, the technician wants to locate a small leak. What is a safe and effective method to find the leak using nitrogen pressure?

  • Use a halide torch to detect the nitrogen leak
  • Apply soap solution to joints and look for bubbles
  • Use a vacuum pump to pull out the nitrogen and check for pressure rise
  • Nitrogen leaks are invisible — you cannot find them while testing

Question 25: A technician is servicing a new R-410A system. What type of lubricating oil is required for R-410A systems, and why?

  • Mineral oil — the same oil used in R-12 systems
  • Polyolester (POE) oil — because it mixes properly with HFC refrigerants
  • Alkylbenzene (AB) oil — used for all modern refrigerants
  • No lubrication is needed — R-410A is self-lubricating
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit45 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)