Free EPA 608 Practice Test ( CORE Exam)-14

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 20 min for 13 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

How to Use This Practice Test

This EPA 608 Core Exam Practice Test 14 has 13 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: The EPA 608 exam is NOT open book — memorize refrigerant ODP/GWP values and recovery rules before the exam.

  • Topics covered: Refrigerant regulations, recovery procedures, leak detection, and refrigerant properties.
  • Passing score: 70% required on each section. Universal certification requires passing all four sections.
  • Questions: 13 multiple-choice, one correct answer each
13
Questions
20 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608 · NEC 2023
EPA 608 Core Exam Practice Test 14
Q1 / 13
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Exam Practice Test 14 — Question List

Question 1: Refrigerant is a good ……………..

  • Insulator
  • Conductor
  • Semi conductor
  • Resistor

Question 2: If vacuum pump is used in passive recovery what should be introduced in system to increase the pressure and avoid moisture freezing?

  • Dry nitrogen
  • CFC refrigerant
  • Hydrogen
  • Carbon

Question 3: What is the main function condenser in the refrigeration system?

  • To store liquid refrigerant
  • To remove heat from refrigerant
  • To remove moisture from refrigerant
  • To add heat to the refrigerant

Question 4: Which of the following refrigerant has highest Global Warming Potential (GWP)?

  • R-12
  • R-134a
  • R - 22
  • R-152a

Question 5: Venting HFC’s since ………………… is violation of section 608 of federal clean air act.

  • July 1, 1992
  • November 14, 1994
  • November 15, 1995
  • August 16, 1990

Question 6: The temperature of the liquid refrigerant entering in the evaporator must be ………….. surrounding air.

  • Less than
  • More than
  • Equal to

Question 7: The high pressure gauge usually measures ………………… pressure

  • Discharge pressure
  • Suction pressure

Question 8: If the high pressure gauge reads unusual high pressure in the refrigeration system the probable cause is ……………..

  • Defective compressor
  • Insufficient refrigerant
  • Condenser fan motor failure
  • Expansion valve failure

Question 9: Systems containing 10 kg of HFC must be leak tested ………….

  • Annually
  • Twice a year
  • Thrice a year
  • Two years once

Question 10: The mixed refrigerants can be separated and reclaimed.

  • True
  • False

Question 11: If a refrigeration system had a major component failure

  • an oil sample should be taken and analyzed
  • immediately refrigerant should recovered
  • a refrigerant sample should be taken and analyzed
  • immediately system should be purged with dry nitrogen

Question 12: What is to be likely occurred in the refrigeration system when the strong odor is detected during the recovery process?

  • A compressor burnout
  • A condenser fan motor burnout
  • Expansion valve failure
  • Oil is mixed with refrigerant

Question 13: During evacuation of a system what is the benefit of using small length and large diameter gauge set hose?

  • reduces the pressure drop and reduces the evacuation time
  • reduces the pressure drop and increases the evacuation time
  • reduces the refrigerant leakage
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.