EPA 608 NEC 2023

EPA 608 Type II & III Practice Test 7

This test mixes Type II and Type III scenario questions side by side, testing your ability to classify equipment, match certification scope, and recognize the correct leak testing and recovery approach for each type.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Type II & III Exam Tip: Certification is scope-limited. Type II certification does not authorize chiller work, and Type III certification does not authorize Type II work.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type II & III Practice Test 7
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type II & III Practice Test 7 — Question List

Question 1: A technician is looking at a residential heat pump. Which certification type covers this equipment?

  • Type III
  • Both equally
  • Neither
  • Type II

Question 2: A technician is looking at a large low-pressure chiller cooling an office tower. Which certification type covers this equipment?

  • Type III
  • Type II
  • Both equally
  • Neither

Question 3: A leak is found on a rooftop package unit, and refrigerant is escaping into the air outside. What type of equipment does this describe?

  • Type III
  • Type II
  • Could be either
  • Cannot be determined

Question 4: A leak is found on a chiller, and outside air is being pulled into the system instead of refrigerant escaping. What type of equipment does this describe?

  • Type II
  • Could be either
  • Cannot be determined
  • Type III

Question 5: A technician is called to a building with two separate cooling systems: a rooftop package unit for the office area and a large centrifugal chiller for the main lobby and labs. What certifications does this technician need to legally service both?

  • Type II only
  • Type III only
  • Core only
  • Both Type II and Type III

Question 6: True or False: Type II certification automatically includes Type III certification.

  • True
  • True, above a certain company size
  • False
  • True, if the technician has 10+ years of experience

Question 7: Which statement correctly matches equipment pressure to type?

  • Type II below atmospheric; Type III above atmospheric
  • Type II above atmospheric; Type III below atmospheric
  • Both above atmospheric
  • Both below atmospheric

Question 8: A technician needs to nitrogen-pressure-test a system as the standard method for finding a leak. Which type of equipment is this technician most likely working on?

  • Type III
  • Type II
  • Neither
  • Both equally, using identical procedures

Question 9: A technician plans to raise system pressure with hot water before checking for a leak. Which type of equipment is this technician most likely working on?

  • Type II
  • Neither
  • Type III
  • Both equally

Question 10: A technician recovers a large liquid refrigerant charge using push-pull recovery. Which equipment type is this most likely on?

  • Type III
  • Neither
  • Type II
  • Both equally

Question 11: A technician checks a purge unit's log as part of routine maintenance. Which equipment type is this technician working on?

  • Type II
  • Type III
  • Neither
  • Both equally

Question 12: True or False: A technician holding Universal certification can legally service both Type II and Type III equipment.

  • False
  • True, only with a supervisor present
  • False, Universal certification excludes Type III
  • True

Question 13: A walk-in cooler at a grocery store needs its compressor replaced. Refrigerant must first be recovered and the correct vacuum level reached. What certification does this job require?

  • Type II
  • Type III
  • Either one
  • No certification

Question 14: During an inspection, a technician finds that a chiller has an unusually high level of non-condensable gases despite the purge unit running normally. What should the technician suspect, and what type of equipment is involved?

  • Overcharge; Type II rooftop unit
  • A broken thermostat; Type I furnace
  • Low oil level; Type II heat pump
  • A leak letting in extra air; Type III chiller

Question 15: True or False: The 10 in. Hg / 15 in. Hg evacuation levels based on charge size apply specifically to Type II equipment.

  • False
  • True, but also to Type III chillers
  • True
  • False, they apply only to Type I

Question 16: Which equipment type experiences moisture intrusion as an ongoing operational concern requiring a dedicated device, the purge unit, to manage it?

  • Type II
  • Neither
  • Type III
  • Type I

Question 17: A technician with only Type III certification is asked to fix a leak on a rooftop package unit. What should they do?

  • Proceed, since they are certified for refrigerant work
  • Decline, since Type III certification does not cover Type II equipment
  • Proceed, but only evacuate to 10 in. Hg
  • Proceed, but only if supervised by anyone

Question 18: Which of these equipment types would use UV dye as a leak detection method in the standard way described for this exam?

  • Type III
  • Neither
  • Only Type I
  • Type II

Question 19: A technician needs to service both a rooftop unit and a chiller at the same commercial building, but their license only covers Type II. What must they do regarding the chiller?

  • Arrange for a Type III certified technician to handle the chiller
  • Service it anyway since it is at the same building
  • Use Type II procedures on the chiller since it is similar equipment
  • Refuse to service either system

Question 20: True or False: Both Type II and Type III certification exams are closed-book only.

  • True
  • False
  • True, except Type III which allows open-book
  • True, except Type II which allows open-book

Question 21: A technician compares the passing scores for the Core, Type I, Type II, and Type III exams. What do all four have in common?

  • All require 70% to pass
  • All require 90% to pass
  • Only Type III requires 70%
  • Passing scores vary randomly by state

Question 22: Which equipment type would a technician expect to service using vapor, liquid, or push-pull recovery methods?

  • Type II
  • Type III
  • Neither
  • Only Type I

Question 23: A technician needs Universal certification. Which four parts must they pass?

  • Core, Type I, Type II, Type III
  • Core, Type II, Type III only
  • Type I, Type II, Type III only
  • Core and Type III only

Question 24: True or False: A technician can pick and choose which certification exams to take based on the equipment they plan to service.

  • False
  • True, but only for Type II
  • True
  • True, but only for Core

Question 25: Which single fact best explains most of the differences between Type II and Type III procedures covered in this test?

  • Type III equipment is newer
  • Type II equipment runs above atmospheric pressure, and Type III equipment runs below it
  • Type II equipment is always bigger
  • Type III equipment does not use refrigerant
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)