EPA 608 NEC 2023

EPA 608 Type II & III Practice Test 4

This test focuses on Type III equipment: large centrifugal chillers used in hospitals, malls, and universities. It covers the below-atmospheric pressure distinction and compares chiller certification scope to Type II.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Type II & III Exam Tip: Type III chillers run below atmospheric pressure, the opposite of Type II. A leak on a chiller pulls air in; it does not push refrigerant out.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Type II & III Practice Test 4
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Type II & III Practice Test 4 — Question List

Question 1: What type of equipment is a large centrifugal chiller used to cool hospitals, malls, and universities?

  • Type III
  • Type I
  • Type II
  • Universal only

Question 2: Type III equipment operates at what pressure compared to the atmosphere?

  • Above atmospheric pressure
  • Exactly at atmospheric pressure
  • Pressure is not relevant
  • Below atmospheric pressure

Question 3: If a Type III chiller has a leak, what happens?

  • Refrigerant is pushed out into the room
  • Outside air is pulled into the system
  • Nothing happens because chillers do not leak
  • The compressor shuts off automatically

Question 4: A technician notices rising pressure readings and a build-up of non-condensable gases inside a low-pressure chiller over time, even though no refrigerant was added. What is the most likely explanation?

  • The refrigerant is multiplying
  • Air and moisture are leaking into the system because it runs below atmospheric pressure
  • The chiller is overcharged
  • The purge unit is adding refrigerant

Question 5: True or False: Type III equipment operates above atmospheric pressure, just like Type II.

  • True
  • True, only during startup
  • True, only in summer
  • False

Question 6: Which of the following is a Type III appliance?

  • Residential split system
  • Rooftop package unit
  • Large low-pressure centrifugal chiller
  • Walk-in cooler

Question 7: Why is a leak on a Type III chiller often harder to notice right away than a leak on a Type II system?

  • Chillers do not have leaks
  • There is no refrigerant loss to smell or see escaping; instead, air leaks in quietly
  • Chillers are always outdoors
  • Chillers use a different refrigerant that has no smell

Question 8: Large centrifugal chillers are most commonly found cooling what kind of buildings?

  • Hospitals, malls, and universities
  • Single-family homes
  • Small offices
  • Food trucks

Question 9: A building engineer reports that a low-pressure chiller's purge unit has been running longer than usual, removing more air than normal. What does this most likely indicate?

  • The chiller has too much refrigerant
  • The purge unit is broken and adding air on purpose
  • The building's air conditioning is set too low
  • The chiller has a leak, letting outside air in

Question 10: Which statement correctly compares Type II and Type III equipment?

  • Type II is always bigger than Type III
  • Type III is only used in homes
  • Type II and Type III use identical leak testing methods
  • Type II runs above atmospheric pressure; Type III runs below it

Question 11: A large low-pressure chiller cooling a university campus most likely requires which certification?

  • Type I
  • Type II
  • No certification needed
  • Type III

Question 12: True or False: A technician with only Type II certification is authorized to service a low-pressure centrifugal chiller.

  • True
  • True, if supervised
  • False
  • True, if the chiller is small

Question 13: A technician with Universal certification, covering Core, Type I, Type II, and Type III, is asked to service a low-pressure chiller. Is this technician authorized?

  • Yes, Universal certification includes all four categories, including Type III
  • No, Universal certification does not include Type III
  • Only if they also have a separate chiller license
  • No, chillers require a special state license instead

Question 14: What is the opposite relationship between leaks and pressure for Type II versus Type III equipment?

  • Type II leaks pull air in; Type III leaks push refrigerant out
  • Both push refrigerant out
  • Type II leaks push refrigerant out; Type III leaks pull air in
  • Both pull air in

Question 15: Which term describes equipment operating at a pressure lower than the surrounding air?

  • Low-pressure, or vacuum
  • High-pressure
  • Neutral pressure
  • Overpressure

Question 16: A facilities manager says their building's chiller never loses refrigerant because the gauges never show a pressure drop. Why might this be misleading for a low-pressure chiller?

  • The gauges are broken
  • Low-pressure chillers cannot leak
  • A leak on a low-pressure chiller pulls air in rather than releasing pressure, so it may not show as a simple pressure drop
  • The refrigerant would evaporate before showing on gauges

Question 17: A technician is asked whether the same 10 in. Hg / 15 in. Hg evacuation rule used for Type II systems also applies directly to a low-pressure Type III chiller. What is the correct answer?

  • Yes, the exact same numbers always apply
  • No, chillers never need to be evacuated
  • Yes, but only for chillers under 100 tons
  • Chillers already run in a vacuum during normal operation, and their evacuation procedures are specific to chiller equipment; do not assume the Type II charge-based rule transfers directly

Question 18: True or False: Type III chillers are generally larger, more specialized equipment than typical Type II appliances.

  • False
  • True
  • True, only in cold climates
  • False, they are always smaller

Question 19: Which of these describes why Type III certification is a separate category from Type II?

  • Type III equipment is identical to Type II, just bigger
  • Type III equipment has different pressure behavior and requires different service knowledge
  • Type III equipment does not use refrigerant
  • Type III equipment is always outdoors

Question 20: A shopping mall's central air conditioning uses a large chiller. Which best describes its likely pressure behavior?

  • Above atmospheric pressure, like a rooftop unit
  • Exactly atmospheric pressure
  • Below atmospheric pressure, since it is likely a low-pressure centrifugal chiller
  • It has no measurable pressure

Question 21: A technician transfers from residential HVAC work to a hospital's central plant, which uses large chillers. The technician holds Core, Type I, and Type II certification. Can they legally begin chiller work?

  • No, they need Type III certification specifically for chiller work
  • Yes, because they already have Core and Type II
  • Yes, because hospitals are exempt from certification rules
  • Yes, as long as they have five years of experience

Question 22: Which pressure condition is unique to Type III equipment compared to Type II?

  • Operating below atmospheric pressure
  • Operating above atmospheric pressure
  • Operating at extremely high pressure
  • Having no pressure at all

Question 23: True or False: A leak on a Type III chiller can introduce moisture into the system along with air.

  • False
  • True, but only in winter
  • True
  • False, chillers are sealed against moisture

Question 24: What is a likely long-term effect of air and moisture continually leaking into a low-pressure chiller?

  • Build-up of non-condensable gases and potential moisture-related problems inside the system
  • Improved efficiency
  • The refrigerant charge increases on its own
  • The chiller automatically repairs the leak

Question 25: Which statement best summarizes the core difference between Type II and Type III equipment covered in this test?

  • Type II is for large buildings; Type III is for homes
  • Type II runs above atmospheric pressure and leaks push refrigerant out; Type III runs below atmospheric pressure and leaks pull air in
  • Both operate at the same pressure
  • Only Type III requires any certification
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)