EPA 608 NEC 2023

EPA 608 Core Practice Test 18

This practice test zeroes in on one of the most tested parts of the EPA 608 Core exam: the difference between recovery, recycling, and reclaiming. You will work through definitions, true-or-false checks, and real job-site scenarios. The test also covers venting bans, leak repair rules, and cylinder safety, so it stays a complete Core review.

TOPICS COVERED
epa 608 practice tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 25 min for 25 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account needed.

The EPA 608 certification is required by law for any technician who purchases or handles refrigerants. It covers safe handling, leak detection, recovery, and environmental regulations.

Type I covers small appliances (≤5 lbs refrigerant), Type II covers high-pressure systems, Type III covers low-pressure systems, and Universal covers all three. Most HVAC technicians pursue Universal certification.

You must score at least 70% on each section of the exam. The Universal exam has four parts: core, Type I, Type II, and Type III.

Core Exam Tip: If a question mentions selling refrigerant to a new owner, the answer almost always involves reclaiming. Recovery and recycling never allow a change of ownership.

25
Questions
25 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

EPA 608
EPA 608 Core Practice Test 18
Q1 / 25
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

EPA 608 Core Practice Test 18 — Question List

Question 1: Which term describes simply removing refrigerant from a system and storing it in an outside container, with no cleaning at all?

  • Recycling
  • Recovery
  • Reclaiming
  • Retrofitting

Question 2: Which term describes cleaning refrigerant on-site, such as separating out oil and reducing moisture, acid, and particles, so it can be reused on the same job or by the same owner?

  • Reclaiming
  • Recovery
  • Venting
  • Recycling

Question 3: Which term describes processing refrigerant at a certified off-site facility until it meets AHRI Standard 700 purity, confirmed by chemical analysis?

  • Recovery
  • Recycling
  • Reclaiming
  • Evacuating

Question 4: Of recovery, recycling, and reclaiming, which is the only one that legally allows the refrigerant to be sold to a new owner?

  • Reclaiming
  • Recovery
  • Recycling
  • All three allow resale equally

Question 5: Which refrigerant process must happen at a certified facility away from the job site?

  • Reclaiming
  • Recovery
  • Recycling
  • None of them require this

Question 6: A technician cleans refrigerant right at the job site, removing oil and reducing moisture, but does not send it to a lab. What has the technician done?

  • Reclaimed the refrigerant
  • Vented the refrigerant
  • Retrofitted the refrigerant
  • Recycled the refrigerant

Question 7: Which of the three processes, recovery, recycling, or reclaiming, involves no cleaning or processing of the refrigerant at all?

  • Reclaiming
  • Recovery
  • Recycling
  • All three involve cleaning

Question 8: A technician recovers refrigerant from one rooftop unit, cleans it on-site with a filter-drier cart, and reuses it in another unit owned by the same building owner. What process did the technician perform after the initial recovery?

  • Reclaiming
  • Venting
  • Evacuation
  • Recycling

Question 9: AHRI Standard 700 sets the purity level that refrigerant must reach for which process?

  • Recovery
  • Recycling
  • Reclaiming
  • Evacuation

Question 10: Which process is confirmed to be complete through chemical analysis of the refrigerant's purity?

  • Recovery
  • Reclaiming
  • Recycling
  • None of them are verified

Question 11: A technician removes refrigerant from a broken chiller and, without any cleaning, stores it in a cylinder to bring back to the shop for later reuse by the same company. What has the technician done so far?

  • Recovery only
  • Reclaiming
  • Recycling
  • Venting

Question 12: True or False: Recycled refrigerant can legally be sold to any new owner, the same as reclaimed refrigerant.

  • False
  • True
  • Only true for HFCs
  • Only true if approved in writing by the EPA each time

Question 13: True or False: Recovery involves cleaning the refrigerant to remove moisture and acid.

  • True
  • Only true for large systems
  • False
  • Only true for HFCs

Question 14: A property owner wants refrigerant recovered from one of their own units reused later in another unit they also own, without selling it to anyone else. Which of the three processes, at minimum, must be performed before reuse?

  • Recovery
  • Reclaiming
  • Venting
  • None, it can be reused immediately with no process

Question 15: Since what date has venting HFC refrigerant into the air been illegal?

  • July 1, 1992
  • November 15, 1995
  • January 1, 1998
  • It has never been illegal to vent HFCs

Question 16: The substantial leak repair rule, with its 15% and 35% thresholds, applies only to appliances with how much refrigerant charge?

  • 50 pounds or more
  • 10 pounds or more
  • 5 pounds or more
  • It applies to all appliances regardless of size

Question 17: How long must a business keep documentation for refrigerant purchases of 2 pounds or more?

  • 6 months
  • 1 year
  • 10 years
  • 3 years

Question 18: When recovering refrigerant into a DOT-approved cylinder, what is the maximum safe fill level by weight?

  • 95% of rated capacity
  • 60% of rated capacity
  • 80% of rated capacity
  • 100% of rated capacity

Question 19: POE and PAG refrigerant oils absorb moisture from the air very quickly. How should they be stored?

  • In open plastic buckets
  • In sealed metal containers
  • In sealed plastic containers
  • Left open to the air so moisture can escape

Question 20: What is the key difference between self-contained and system-dependent recovery equipment?

  • There is no real difference between them
  • System-dependent equipment is always faster
  • Self-contained equipment can only be used on HFCs
  • Self-contained equipment has its own compressor; system-dependent equipment relies on the appliance's compressor

Question 21: How is evacuation with a vacuum pump different from refrigerant recovery?

  • Evacuation removes air and moisture and is exhausted to the atmosphere, since there is no refrigerant left to protect
  • They are exactly the same process with different names
  • Evacuation is illegal, while recovery is legal
  • Evacuation only applies to HFC refrigerants

Question 22: Which refrigerants have an Ozone Depletion Potential (ODP) above zero?

  • Refrigerants with a high boiling point
  • Refrigerants that contain chlorine or bromine
  • All refrigerants equally
  • Only synthetic blends

Question 23: What score must a technician earn to pass the Core section of the EPA 608 exam?

  • 50%
  • 84%
  • 70%
  • 90%

Question 24: Before using a recovery cylinder, what should a technician check on it that relates to periodic hydrostatic retesting?

  • The paint color only
  • The brand name printed on it
  • Nothing, cylinders never need retesting
  • The stamped retest date

Question 25: A technician is under time pressure and considers releasing a small amount of leftover refrigerant into the air instead of recovering it. Is this allowed?

  • Yes, small amounts are always allowed
  • Yes, but only for HFC refrigerants
  • No, venting refrigerant is illegal, no matter the amount
  • Yes, as long as no one is watching
Study Tip: The EPA 608 exam is closed book. Memorize: recovery is required before opening any refrigerant system. Venting refrigerant is illegal. Know the ODP and GWP values for R-22, R-410A, R-134a, R-32, and R-454B.
EXAM CARD EPA 608
Questions25
Time limit25 min
Pass score70%
RegulationEPA Section 608
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: EPA Section 608 (40 CFR Part 82)