NEC CODE NEC 2023

NEC Code Questions Practice Test-20

Take a Practice test on NEC Code Practice quiz questions - 20

TOPICS COVERED
NEC Practice Tests

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 14 min for 9 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — free, no signup required. Each question links to the relevant NEC article so you can study the code directly.

The National Electrical Code (NFPA 70) is the benchmark standard for safe electrical installation in the US. It is updated every 3 years by the NFPA.

Study the edition adopted by your state. As of 2025, most states use the 2020 or 2023 NEC. These tests are written to the 2023 edition.

The most tested articles are 100 (Definitions), 200–250 (Wiring & Grounding), 300–314 (Wiring Methods), 400–411 (Conductors), 430 (Motors), and 700–701 (Emergency Systems).
9
Questions
14 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

NEC CODE · NEC 2023
NEC Code Questions Practice Test-20
Q1 / 9
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Student Reviews

No reviews yet — be the first to share your experience!

Leave a Review

5 stars
0/1000

NEC Code Questions Practice Test-20 — Question List

Question 1: What is the maximum voltage drop that is recommended by NEC for branch conductor and feeder conductor?

  • 3 %
  • 5 %
  • 8 %
  • 4 %

Question 2: What is the minimum load that is required for exterior sign or outline lightening for a commercial occupancy as per NEC?

  • 12000 VA
  • 18000 VA
  • 15000 VA
  • 21000 VA

NEC Reference: NEC 220.14(F)

Question 3: A cord and plug device used as disconnecting means for a motor must be rated for ..................

  • Horsepower
  • voltage
  • Resistance
  • Current

NEC Reference: NEC 430.109(F)

Question 4: A 2400 volts motor disconnecting means must be capable of being locked in the .....................

  • closed position
  • Open position
  • ON position
  • Both open and close position

NEC Reference: NEC 430.227

Question 5: If the branch circuit rating more than ................., the lamp holders connected to it should be of the heavy duty type.

  • 20 amperes
  • 25 amperes
  • 40 amperes
  • 45 amperes

NEC Reference: NEC 210.21(A)

Question 6: All 15 or 20 amperes receptacle outlets installed in bathrooms of dwelling units must always require .............................

  • Non ground recetacles
  • water proof receptacles
  • protective gaurds
  • Ground fault circuit interceptor ( GFCI)

NEC Reference: NEC 210.8(A)(1)

Question 7: How much power consumed by 240 volts circuit that draws 30 amperes current?

  • 7.2 KW
  • 5.2 KW
  • 8.5 KW
  • 9.3 KW

Question 8: For conductors supplying portable signs in a dry location what is the maximum length in feet allowed?

  • 16
  • 12
  • 15
  • 8

NEC Reference: NEC 600.10(D)(2)

Question 9: For a commercial kitchen with two electrical equipment, what demand factor is allowed?

  • 100 %
  • 80 %
  • 70 %
  • 90 %

NEC Reference: NEC 220.56

EXAM CARD NEC CODE
Questions9
Time limit14 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate